Real-time respiratory management of this study using the respiration synchronized way in order to reduce the near critical organs irradiation size and dose in humans (Real-time position management system; RPM system) the Gating system targets 10 Abdomen tumor patients with a apply tumor dose than the protection and irradiation size and want to prove more effective treatment plans as a clearance out the usefulness of tumor treatment by a movement of reduction and breathing surrounding Gating and irradiation according to the presence of Non-gating system critical normal tissues after the long-term analysis of the dose to give a variety of results. Concentration dose to tumor tissue on the basis of the research and treatment given the Gating through which to reduce the dose to be applied to critical organs near has been determined that more useful accuracy and precision increase in medical treatment burden for the patient compared to the external of the study concluded that treatment should be continued progress to improve the area. Concentration dose to tumor tissue on the basis of the research and treatment given the Gating through which to reduce the dose to be applied to critical organs near has been determined that more useful accuracy and precision increase in medical treatment burden for the patient compared to the external of the the study concluded that treatment should be continued progress to improve the area.
Abstract
Real-time respiratory management of this study using the respiration synchronized way in order to reduce the near critical organs irradiation size and dose in humans (Real-time position management system; RPM system) the Gating system targets 10 Abdomen tumor patients with a apply tumor dose than the protection and irradiation size and want to prove more effective treatment plans as a clearance out the usefulness of tumor treatment by a movement of reduction and breathing surrounding Gating and irradiation according to the presence of Non-gating system critical normal tissues after the long-term analysis of the dose to give a variety of results. Concentration dose to tumor tissue on the basis of the research and treatment given the Gating through which to reduce the dose to be applied to critical organs near has been determined that more useful accuracy and precision increase in medical treatment burden for the patient compared to the external of the study concluded that treatment should be continued progress to improve the area. Concentration dose to tumor tissue on the basis of the research and treatment given the Gating through which to reduce the dose to be applied to critical organs near has been determined that more useful accuracy and precision increase in medical treatment burden for the patient compared to the external of the the study concluded that treatment should be continued progress to improve the area.
참고문헌 (28)
- 안소현, "The Effect of Breathing Biofeedback on Breathing Reproducibility and Patient’s Dose in Respiration-gated Radiotherapy", 의학물리, 24(3), pp.135~139 (2013), 한국의학물리학회[DOI]
- Balter JM, "Improvement of CT-based rreatment planning models of abdominal target using static exhale imaging", Int. J. Radiat. Oncol. Biol. Phys, 41(4), pp.939~943 (1998)
- Balter JM, "Uncertainties in CT-based radiation therapy treatment planning associated with patient breathing", Int. J. Radiat. Oncol. Biol. Phys, 36(1), pp.167~174 (1996)
- Barnes EA, "Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration", Int. J. Radiat. Oncol. Phys, 50(4), pp.1091~1098 (2001)
- Cho YJ, "Evaluation on usefulness of abdomen and chest motion control device (ABCHES) for the tumor with a large respiratory motion in radiotherapy", J. Korean Soc. Radiat. Therapy, 24(2), pp.85~93 (2012)
- Colgan R, "Planning lung radiotherapy using 4D CT data and a motion model", Phys. Med. Biol, 53(20), pp.5815~5830 (2008)
- Guckenberger M, "Four-dimensional treatment planning for stereotactic body radiotherapy", Int. J. Radiat. Oncol. Biol. Phys, 69(1), pp.276~285 (2007)
- Heinzerling JH, "Four-Dimensional computed tomography scan analysis of tumor and organ motion at varying level of abdominal compression during stereotaxic treatment of lung and liver", Int. J. Radiat. Oncol. Biol. Phys, 70(5), pp.1571~1578 (2008)
- Jang ES, "Accuracy evaluation of tumor therapy during respiratory gated radiation therapy", J. Korean Soc. Radiat. Therapy, 22(2), pp.113~122 (2010)
- Ji YS, "Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy", Ann. Nucl. Energy, 38(11), pp.2569~2574 (2011)
- Keall PJ, "Geometric accuracy of a real-time target tracking system with dynamic multileaf collimatortracking system", Int. J. Radiat. Oncol. Biol. Phys, 65(5), pp.1579~1584 (2006)
- Keall PJ, "The management of respiratory motion in radiation oncology report of AAPM TG 76", Med. Phys, 33(10), pp.3874~3900 (2006)
- 권대철, "Comparison of the Measured Stem Leakage Correction Factor for an Ionization Chamber in Air to the Monte Carlo Simulation", Journal of the Korean Physical Society, 58(5), pp.1184~1194 (2011), 한국물리학회
- 권대철, "An Overall Stem Effect, including Stem Leakage and Stem Scatter, for a TM30013 Farmer-type Chamber", Journal of the Korean Physical Society, 58(6), pp.1688~1696 (2011), 한국물리학회
- 권경태, "호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가", 의학물리, 19(1), pp.14~20 (2008), 한국의학물리학회
- Kubo HD, "Respiration gated radiotherapy treatment: a technical study", Phys. Med. Biol, 41(1), pp.83~91 (1996)
- 이재승, "환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가", 방사선방어학회지, 36(1), pp.8~15 (2011), 대한방사선방어학회
- Lujan AE, "A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion", Med. Phys, 30(10), pp.2643~2649 (2003)
- Neicu T, "Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching", Phys. Med. Biol, 51(3), pp.617~636 (2006)
- Ramsy CR, "Clinical efficacy of respiratory gated conformal Therapy", Med. Dosim, 24(2), pp.115~119 (2006)
- Rietzel E, "Design of 4D treatment planning target volumes", Int. J. Radiat. Oncol. Biol. Phys, 66(1), pp.287~295 (2006)
- 신은혁, "호흡연습장치를 적용한 호흡교정법의 영향 평가", Radiation oncology journal, 26(3), pp.181~188 (2008), 대한방사선종양학회
- 송주영, "폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석", 의학물리, 19(4), pp.263~268 (2008), 한국의학물리학회
- Underberg RWM, "Benefit of respiration gated stereotactic radiotherapy for stage lung cancer an analysis of 4D CT datasets", Int. J. Radiat. Oncol. Biol. Phys, 62(2), pp.554~560 (2005)
- Vedam SS, "Acquiring a four dimensional computed tomography dataset using an external respiratory signal", Phys. Med. Biol, 48(1), pp.45~62 (2003)
- Wagman R, "Respiratory gating for liver tumors: use in dose escalation", Int. J. Radiat. Oncol. Biol. Phys, 55(3), pp.659~668 (2003)
- Wink NM, "Individualized gating windows based on four-dimensional CT information for respiration-gated radiotherapy", Phys. Med. Biol, 53(1), pp.165~175 (2008)
- Wunderink W, "Target coverage in image-guided stereotactic body radiotherapy of liver tumors", Int. J. Radiat. Oncol. Biol. Phys, 68(1), pp.282~290 (2007)