Open, Active-Controlled Clinical Study to Evaluate the Correlation between Whole Body DEXA and BIA Muscle Measurements
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: Dual energy X-ray absorptiometry (DXA) is the gold standard for diagnosing sarcopenia. However, comparative studies using bioelectrical impedance analysis (BIA) would be required in the Korean population. This study aimed to evaluate the correlation between total-body bone density measuring devices (Hologic and GE Lunar) and a bioelectrical impedance measurement device (InBody 970) as well as the correlation between upper body muscle mass. Methods: A total of 119 participants were involved in this study, aged 20 to 70 years, with specific body mass index ranges and no severe health conditions used both DXA (or DEXA) and BIA technologies to assess body composition. The participants were scanned using a Hologic QDR-4500W DXA scanner and GE-Lunar Prodigy DXA systems, and the InBody 970 type of multi-frequency BIA machine. Statistical analysis was performed to determine the correlation between the devices, with a coefficient of at least 0.8. Results: The muscle mass measurement comparisons between the InBody 970 and Hologic devices demonstrated remarkably high correlation coefficients (exceeding 0.9) across all limbs. Similarly, the muscle mass comparison between the Inbody 970 and GE Lunar devices also revealed substantial correlation coefficients, ranging from 0.83 upwards, across all limbs. Conclusions: Limb muscle mass measurements using Hologic and GE Lunar whole-body DXA and Inbody 970 BIA demonstrated particularly high levels of concordance. In addition, a conversion formula that bridges limb muscle mass measurements from two widely used whole-body DXA machines and a BIA machine will facilitate sarcopenia research and patient management.
Abstract
Background: Dual energy X-ray absorptiometry (DXA) is the gold standard for diagnosing sarcopenia. However, comparative studies using bioelectrical impedance analysis (BIA) would be required in the Korean population. This study aimed to evaluate the correlation between total-body bone density measuring devices (Hologic and GE Lunar) and a bioelectrical impedance measurement device (InBody 970) as well as the correlation between upper body muscle mass. Methods: A total of 119 participants were involved in this study, aged 20 to 70 years, with specific body mass index ranges and no severe health conditions used both DXA (or DEXA) and BIA technologies to assess body composition. The participants were scanned using a Hologic QDR-4500W DXA scanner and GE-Lunar Prodigy DXA systems, and the InBody 970 type of multi-frequency BIA machine. Statistical analysis was performed to determine the correlation between the devices, with a coefficient of at least 0.8. Results: The muscle mass measurement comparisons between the InBody 970 and Hologic devices demonstrated remarkably high correlation coefficients (exceeding 0.9) across all limbs. Similarly, the muscle mass comparison between the Inbody 970 and GE Lunar devices also revealed substantial correlation coefficients, ranging from 0.83 upwards, across all limbs. Conclusions: Limb muscle mass measurements using Hologic and GE Lunar whole-body DXA and Inbody 970 BIA demonstrated particularly high levels of concordance. In addition, a conversion formula that bridges limb muscle mass measurements from two widely used whole-body DXA machines and a BIA machine will facilitate sarcopenia research and patient management.
참고문헌 (32)
- Voulgaridou G, "Increasing muscle mass in elders through diet and exercise : a literature review of recent RCTs", Foods, 12, pp.1218~ (2023)[DOI]
- Liu X, "Precision intervention for sarcopenia", Precis Clin Med, 5, pp.pbac013~ (2022)[DOI]
- Bianchetti A, "Sarcopenia in the elderly : from clinical aspects to therapeutic options", Geriatr Care, 5, pp.8033~ (2019)[DOI]
- Povoroznyuk VV, "The association of sarcopenia and osteoporosis and their role in falls and fractures : literature review", Med Perspekt, 26, pp.111~119 (2021)[DOI]
- Park S, "Effects of changes in multiple chronic conditions on medical costs among older adults in South Korea", Healthcare(Basel), 10, pp.742~ (2022)[DOI]
- Kim M, "Economic burden of opioid misuse focused on direct medical costs", Front Pharmacol, 13, pp.928890~ (2022)[DOI]
- Garg R, "Direct medical costs of young-onset colorectal cancer : a worldwide systematic review", BMC Health Serv Res, 22, pp.1100~ (2022)[DOI]
- Li D, "The effect of medical choice on health costs of middle-aged and elderly patients with chronic disease : based on principal-agent theory", Int J Environ Res Public Health, 19, pp.7570~ (2022)[DOI]
- Cruz-Jentoft AJ, "Sarcopenia : revised European consensus on definition and diagnosis", Age Ageing, 48, pp.601~ (2019)[DOI]
- Oliveira JB, "Revised diagnostic criteria and classification for the autoimmune lymphoproliferative syndrome(ALPS) : report from the 2009 NIH International Workshop", Blood, 116, pp.e35~e40 (2010)[DOI]
- Sherlin L, "A position paper on neurofeedback for the treatment of ADHD", J Neurother, 14, pp.66~78 (2010)[DOI]
- Leckman JF, "Obsessive-compulsive disorder : a review of the diagnostic criteria and possible subtypes and dimensional specifiers for DSM-V", Depress Anxiety, 27, pp.507~527 (2010)[DOI]
- Won CW, "Management of sarcopenia in primary care settings", Korean J Fam Med, 44, pp.71~75 (2023)[DOI]
- Yoshiji H, "Evidence-based clinical practice guidelines for liver cirrhosis 2020", Hepatol Res, 51, pp.725~749 (2021)[DOI]
- O’Callaghan S, "A clinical audit of detection and management of sarcopenia in older persons’ specialist rehabilitation services in an academic teaching hospital", Age Ageing, 48(Suppl 3), pp.iii17~iii65 (2019)[DOI]
- Anker SD, "Welcome to the ICD-10 code for sarcopenia", J Cachexia Sarcopenia Muscle, 7, pp.512~514 (2016)[DOI]
- Donini LM, "Definition and diagnostic criteria for sarcopenic obesity : ESPEN and EASO consensus statement", Obes Facts, 15, pp.321~335 (2022)[DOI]
- Donato B, "The evaluation of sarcopenia in non-dialysis chronic kidney disease stages by computed tomography", Nephrol Dial Transplant, 36(Suppl 1), pp.gfab089.04~ (2021)[DOI]
- Kamiya K, "Sarcopenia : prevalence and prognosis in older patients with cardiovascular disease", Innov Aging, 1(Suppl 1), pp.599~ (2017)[DOI]
- Chen M, "Association between body fat and elevated blood pressure among children and adolescents aged 7-17 years : using dual-energy X-ray absorptiometry(DEXA)and bioelectrical impedance analysis(BIA)from a cross-sectional study in China", Int J Environ Res Public Health, 18, pp.9254~ (2021)[DOI]
- Yi Y, "A comparative study of high-frequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry for estimating body composition", Life(Basel), 12, pp.994~ (2022)[DOI]
- Samouda H, "Body fat assessment in youth with overweight or obesity by an automated bioelectrical impedance analysis device, in comparison with the dual-energy x-ray absorptiometry : a cross sectional study", BMC Endocr Disord, 22, pp.195~ (2022)[DOI]
- Lahav Y, "Comparison of body composition assessment across body mass index categories by two multifrequency bioelectrical impedance analysis devices and dual-energy X-ray absorptiometry in clinical settings", Eur J Clin Nutr, 75, pp.1275~1282 (2021)[DOI]
- Ha YC, "Cross-calibration of bone mineral densities and body composition between GE lunar prodigy and osteosys primus", J Bone Metab, 28, pp.215~221 (2021)[DOI]
- Wang X, "Sample size estimation in clinical research : From randomized controlled trials to observational studies", Chest, 158, pp.S12~s20 (2020)[DOI]
- Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
- Hsieh KC, "The validity and accuracy in foot-to-foot bioelectrical impedance analysis measuring models referenced by dual-energy X-ray absorptiometry in body composition in standing position", Afr J Biotechnol, 10, pp.3222~3231 (2011)[DOI]
- Malavolti M, "Cross-calibration of eight-polar bioelectrical impedance analysis versus dual-energy X-ray absorptiometry for the assessment of total and appendicular body composition in healthy subjects aged 21-82 years", Ann Hum Biol, 30, pp.380~391 (2003)[DOI]
- Kim M, "Comparison of segmental multifrequency bioelectrical impedance analysis with dual-energy X-ray absorptiometry for the assessment of body composition in a community-dwelling older population", Geriatr Gerontol Int, 15, pp.1013~1022 (2015)[DOI]
- Meier NF, "Validation of a multielectrode bioelectrical impedance analyzer with a dual-energy X-ray absorptiometer for the assessment of body composition in older adults", J Aging Phys Act, 28, pp.598~604 (2020)[DOI]
- Fang WH, "Accuracy augmentation of body composition measurement by bioelectrical impedance analyzer in elderly population", Medicine(Baltimore), 99, pp.e19103~ (2020)[DOI]
- Jeon KC, "Prediction equations of the multifrequency standing and supine bioimpedance for appendicular skeletal muscle mass in Korean older people", Int J Environ Res Public Health, 17, pp.5847~ (2020)[DOI]