척추경 나사못의 디자인이 고정력 및 구동 토크에 미치는영향 분석: 이중 나사 및 이중 피치 나사
Mechanical Performance Comparison of Pedicle Screw Based on Design Parameters: Dual Lead and Dual Pitch
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
One of the most common problems with pedicle screw system is pullout of the screw. This study was performed to evaluate the pullout strength and driving torque of newly designed pedicle screws. The design of three type screws were standard pedicle screw, which had single lead threaded and single pitched design (Type A), single pitched and dual lead threaded pedicle screw (Type B), dual pitched and dual lead threaded pedicle screw (Type C), respectively. The tests were performed in accordance with the ASTM standards using polyurethane (PU) foam blocks. There was no significant difference in pullout strength among three types of screw. Type B and Type C exhibited higher insertion torque and removal torque than Type A, respectively (p<0.05). Pedicle screws newly developed with dual pitched and dual lead threaded design showed higher driving torque without decrease in pullout strength compared to the standard pedicle screw and could be inserted more rapidly with the same number of revolutions.
Abstract
One of the most common problems with pedicle screw system is pullout of the screw. This study was performed to evaluate the pullout strength and driving torque of newly designed pedicle screws. The design of three type screws were standard pedicle screw, which had single lead threaded and single pitched design (Type A), single pitched and dual lead threaded pedicle screw (Type B), dual pitched and dual lead threaded pedicle screw (Type C), respectively. The tests were performed in accordance with the ASTM standards using polyurethane (PU) foam blocks. There was no significant difference in pullout strength among three types of screw. Type B and Type C exhibited higher insertion torque and removal torque than Type A, respectively (p<0.05). Pedicle screws newly developed with dual pitched and dual lead threaded design showed higher driving torque without decrease in pullout strength compared to the standard pedicle screw and could be inserted more rapidly with the same number of revolutions.
참고문헌 (26)
- O. Yaman, "The comparison of pullout strengths of various pedicle screw designs on synthetic foams and ovine vertebrae", Turk Neurosurg., 25(4), pp.532~538 (2015)
- C.S. Chen, "Failure analysis of broken pedicle screws on spinal instrumentation", Medical Engineering and Physics, 27, pp.487~496 (2005)[DOI]
- S. Vishnubhotla, "A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screws", Spine, 11, pp.777~781 (2011)[DOI]
- S. Wan, "Biomechanical and histological evaluation of an expandable pedicle screw in osteoporotic spine in sheep", Eur Spine, 19, pp.2122~2129 (2010)[DOI]
- B.B. Abshire, "Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out", Spine, 1, pp.408~414 (2001)[DOI]
- C.C. Hsu, "Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses", Orthopedic Research, 23, pp.788~794 (2005)[DOI]
- C.A. Lill, "Mechanical performance of cylindrical and dual core pedicle screws in calf and human vertebrae", Arch Orthop Trauma Surg., 126, pp.686~694 (2006)[DOI]
- V.M. Praveen, "Biomechanical evaluation of a double threaded pedicle screw in elderly vertebrae", Journal of spinal disorders& techniques, 15(1), pp.64~68 (2002)[DOI]
- ASTM Standards, "F543-17, Standard Specification and Test Methods for Metallic Medical Bone Screws", ~ (2017)
- ASTM Standards, "F1839-08(2016), Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments", ~ (2016)
- B.S. Myers, "The role of imaging and in situ biomechaical testing in assessing pedicle screw pull-out strength", Spine, 21, pp.1962~1968 (1996)[DOI]
- C.A. Dickman, "Transpedicular screw-rod fixation of the lumbar spine: Operative technique and outcome in 104 cases", J. Neurosurg., 77, pp.860~870 (1992)[DOI]
- K. Okuyama, "Can insertional torque predict screw loosening and related failures? An in vivo study of pedicle screw fixation augmenting posterior lumbar interbody fusion", Spine, 25, pp.858~864 (2000)[DOI]
- S.M. Renner, "Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method", Spine, 29(11), pp.212~216 (2004)[DOI]
- U. Talu, "Pedicle screw salvage: The effect of depth and diameter on pull-out strength: A biomechanical study", Acta Orthop Traumatol Turc, 34, pp.300~307 (2000)
- A.W.L. Kwok, "Insertional torque and pull-out strengths of conical and cylindrical pedicle screws in cadaveric bone", Spine, 21, pp.2429~2434 (1996)[DOI]
- L.B. Brasiliense, "Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spine", Spine J, 13(8), pp.947~956 (2013)[DOI]
- S.L. Evans, "Bone cement of bone substitute augmentation of pedicle screws improves pullout strength in posterior spinal fixation", Material Science, 13, pp.1143~1145 (2002)
- T. Suzuki, "Improving the pullout strength of pedicle screws by screw coupling", J Spinal Disord., 14, pp.399~403 (2001)[DOI]
- A.W. Turner, "Hydroxyapatite composite resin cement augmentation of pedicle screw fixation", Clin Orthop Relat Res., 406, pp.253~261 (2003)[DOI]
- D.W. Polly Jr, "Revision pedicle screws: Bigger, longer shims-what is best?", Spine, 23, pp.1374~1379 (1998)[DOI]
- R. Skinner, "Experimental pullout testing and comparison of variables in transpedicular screw fixation: A biomechanical study", Spine, 15, pp.195~201 (1990)[DOI]
- Y.Y. Kim, "Assessment of pedicle screw pullout strength based on various screw designs and bone densities", Spine J, 12, pp.164~168 (2012)[DOI]
- M.H. Krenn, "Influence of thread design on pedicle screw fixation", J Neurosurg Spine, 9, pp.90~95 (2008)[DOI]
- T.K. Daftari, "Correlations between screw hole preparation, torque of insertion, and pullout strength for spinal screws", J Spinal Disord., 7(2), pp.139~145 (1994)[DOI]
- K. Mizuno, "Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation: short-term observation", J Orthop Sci., 10(2), pp.137~144 (2005)[DOI]
