수산화인회석 코팅 임플란트와 sandblasted, large-grit and acid-etched implant의 안정성에 대한 임상연구
A study of stability of hydroxy-apatite coated implants and sandblasted, large-grit and acid-etched implants
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to compare the stability of two types of surface treated implants. Materials and Methods: Participants in the experimental group were divided into two groups; the hydroxyapatite (HA)-coated implant group and the sandblasted with large grit and acid etched (SLA) implant group. For each group, implants were installed at various sites from anterior teeth to posterior teeth. The stability of each implant was then evaluated and compared. Stability of each implant was evaluated using Osstell-mento and Periotest immediately after installation, and six weeks and 12 weeks after installation. Paired t-test and independent samples t-test were used in comparison and analysis of each measurement. Results: Measurements using Osstell-mento were found to increase with time in both the HA-coated implant and SLA implant groups. At 12 weeks after installation, only HA-coated implants showed statistical significance. However, using Periotest, no statistical significance was observed. In comparisonof HA-coated implants and SLA implants, no significant difference was observed between the two groups. Conclusion: HA-coated implants and SLA implantsinstalled at various sites with excellent initial stability showed successful osseointegration. With excellent initial stability, surface treatment of implants does not appear to have a signifi cant effect on the stability of the implant.
Abstract
Purpose: The purpose of this study was to compare the stability of two types of surface treated implants. Materials and Methods: Participants in the experimental group were divided into two groups; the hydroxyapatite (HA)-coated implant group and the sandblasted with large grit and acid etched (SLA) implant group. For each group, implants were installed at various sites from anterior teeth to posterior teeth. The stability of each implant was then evaluated and compared. Stability of each implant was evaluated using Osstell-mento and Periotest immediately after installation, and six weeks and 12 weeks after installation. Paired t-test and independent samples t-test were used in comparison and analysis of each measurement. Results: Measurements using Osstell-mento were found to increase with time in both the HA-coated implant and SLA implant groups. At 12 weeks after installation, only HA-coated implants showed statistical significance. However, using Periotest, no statistical significance was observed. In comparisonof HA-coated implants and SLA implants, no significant difference was observed between the two groups. Conclusion: HA-coated implants and SLA implantsinstalled at various sites with excellent initial stability showed successful osseointegration. With excellent initial stability, surface treatment of implants does not appear to have a signifi cant effect on the stability of the implant.
참고문헌 (18)
- Adell R, "Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 5, pp.347~359 (1990)
- Brånemark PI, "Introduction to osseointegration, In Tissue-integrated prostheses. Osseointegration in clinical dentistry", pp.11~76 (1985), Quintessence Publishing Co.
- Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs", J Biomed Mater Res, 25, pp.889~902 (1991)
- Deporter DA, "A histological assessment of the initial healing response adjacent to porous-surfaced, titanium alloy dental implants in dogs", J Dent Res, 65, pp.1064~1070 (1986)
- Esposito M, "Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis", Eur J Oral Sci, 106, pp.721~764 (1998)
- Friberg B, "A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study", Int J Oral Maxillofac Surg, 28, pp.297~303 (1999)
- Glauser R, "Initial implant stability using diff erent implant designs and surgical techniques", Appl Osseointegration Res, 2, pp.6~8 (2001)
- Gottlander M, "Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone", Int J Oral Maxillofac Implants, 6, pp.399~404 (1991)
- Jaffin RA, "The excessive loss of Branemark fi xtures in type IV bone: a 5-year analysis", J Periodontol, 62, pp.2~4 (1991)
- Kasemo B, "Biomaterial and implant surfaces: a surface science approach", Int J Oral Maxillofac Implants, 3, pp.247~259 (1988)
- Lekholm M, "Patient selection and preparation Tissue integrated Prostheses", J Periodont, 3, pp.199~209 (1985)
- Meredith N, "On the clinical measurement of implant stability and osseointegration", 박사, pp.1997
- O'Sullivan D, "Measurements comparing the initial stability of five designs of dental implants: a human cadaver study", Clin Implant Dent Relat Res, 2, pp.85~92 (2000)
- Overgaard S, "Role of diff erent loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods", J Orthop Res, 14, pp.888~894 (1996)
- Piattelli A, "Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experimental study in rabbits", Int J Oral Maxillofac Implants, 13, pp.805~810 (1998)
- Wennerberg A, "Design and surface characteristics of 13 commercially available oral implant systems", Int J Oral Maxillofac Implants, 8, pp.622~633 (1993)
- Yoshinari M, "Properties of hydroxyapatitecoated Ti-6Al-4V alloy produced by the ion-plating method", Bull Tokyo Dent Coll, 32, pp.147~156 (1991)
- Yoshinari M, "Thin hydroxyapatite coating produced by the ion beam dynamic mixing method", Biomaterials, 15, pp.529~535 (1994)
