Abstract
In order to develop Korean hearing aid prescription method, this study examined features of gain, frequency response curves, saturation sound pressure level 90 (SSPL90), output sound pressure level 90 (OSPL90), compression threshold (CT), and compression ratio (CR), and attack time (AT)/release time (RT) of linear and non-linear hearing aids. Futhermore, Korean studies related to characteristics of physique, psychoacoustics, speech and language effects were summarized. Following review and summarization, several suggestions for Korean hearing aid prescription method were also presented. Results showed that there were some differences in gain and frequency response curves, SSPL90 or OSPL90 among each hearing aid prescription methods despite the similarity of race and languages. Several factors were considered for calculating CT, CR, AT and RT, dynamic range, speech audibility, signal-to-noise ratio and tonal quality. However there were no agreements on the calculation of those parameters because several preferred factors were not identical among hearing impaired people. Korean hearing aid prescription method is not developed yet. Currently when the hearing aids are imported, fitting softwares with hearing prescription methods come without consideration of differences in acoustic characteristics of Korean language. In conclusion, we strongly suggest that various fundamental studies should be explored for the effective method for aural rehabilitation in Korean hearing impaired listeners.
참고문헌 (40)
- 방은주, "실이대다이얼차의 검사-재검사 신뢰도에 관한 연구", 청능재활, 3(1), pp.85~87 (2007)
- 서옥기, "청력손실의 종류에 따른 불쾌역치와역동범위 고찰", 대한청각학회지, 5(2), pp.111~119 (2001)
- 신은영, "정상청력을 가진 한국 성인의 음량증가의 특성", 청능재활, 4(1), pp.64~68 (2008)
- 이경원, "한국어음을 이용한 다화자잡음의 개발시안", 청능재활, 4(1), pp.24~27 (2008)
- 이경원, "단측 보청기 착용 시 한국 감각신경성난청 성인의 2-cc 커플러이득과 NAL-NL1의 비교", 청능재활, 4(1), pp.69~73 (2008)
- 이미소, "성인의 외이도형 보청기 착용 시 실이착용이득과 1cc 커플러이득의 비교", 대한청각학회지, 6(2), pp.136~141 (2002)
- 유경, "커플러이득(Coupler Gain)과 실이삽입이득(REIG)의 비교연구", 언어청각장애연구, 7(3), pp.179~189 (2002), 한국언어청각임상학회
- 이정학, "유소아와 성인의 실이반응과 2 CC 커플러반응의 비교", 한국청각학회 발표자료 (2004)
- 이주현, "한국어 음소의 주파수 특성에 관한 연 구", 청능재활, 1(1), pp.59~66 (2005)
- 한희경, "A study on the reference sound pressure level used for Korean speech audiometer", 석사, pp.2008
- Barker C, "Client preferences for compression threshold in single-channel wide dynamic range compression hearing aids", Ear Hear, 20, pp.127~139 (1999)
- Barker C, "Fitting low ratio compression to people with severe and profound hearing losses", Ear Hear, 22, pp.130~141 (2001)
- Berger K, "The hearing aid-its operation and development. Livonia, MI: National Hearing Aid Society. 1984. in Hearing Aids", pp.236~ (2001), Thieme
- Boike KT, "Effect of compression ratio on speech recognition and speech-quality ratings with wide dynamic range compression amplification", J Speech Lang Hear Res, 43, pp.456~468 (2001)
- Byrne D, "Hearing aid selection for the 1990s: Where to?", J Am Acad Audiol, 7, pp.377~395 (1996)
- Byrne D, "The National Acoustic Laboratories (NAL) new procedure for selecting the gain and frequency response of a hearing aid", Ear Hear, 7, pp.257~265 (1986)
- Byrne D, "NAL-NL1. procedure for fitting non-linear hearing aids: Characteristics and comparisons with other procedures", J Am Acad Audiol, 12, pp.37~51 (2001)
- Byrne D, "Selecting the gain of hearing aids for persons with sensorineural hearing impairments", Scand Audiol, 5, pp.51~59 (1976)
- Cornelisse L, "The input", output formula: a theoretical approach to the fitting of personal amplification devices, 1995, pp.97, 1854~1864
- Cox RM, "Using loudness data for hearing aid selection: The IHAFF approach", Hear J, 48(2), pp.10~44 (1995)
- Cox RM, "The contour test of loudness perception", Ear Hear, 18, pp.388~400 (1997)
- Cox RM, "Accuracy of predicted ear canal speech levels using the VIOLA input", output-based fitting strategies, 1998, pp.19, 139~148
- Dillon H, "NAL-NL1: A new prescriptive fitting procedure for nonlinear hearing aids", Hear J, 52(4), pp.10~16 (1999)
- Elberling C, "Loudness Scaling Revisited", J Am Acad Audiol, 10(5), pp.248~260 (1999)
- Hansen M, "Effects of multi-channel compression time constants on subjectively perceived sound quality and speech intelligibility", Ear Hear, 23, pp.369~380 (2002)
- Henning RLW, "The effects of hearing aid compression parameters on the short-term dynamic range of continuous speech", J Speech Lang Hear Res, 51, pp.471~484 (2008)
- Hornsbya BWY, "The effects of compression ratio, signalto- noise ratio, and level on speech recognition in normal-hearing listeners", J Acoust Soc Am, 109(6), pp.2964~2973 (2001)
- Jenstad LM, "Quantifying the effect of compression hearing aid release time on speech acoustics and intelligibility", J Speech Lang Hear Res, 48, pp.651~667 (2005)
- Keidser G, "The Preferred Number of Channels (One, Two, or Four) in NAL-NL1 Prescribed Wide Dynamic Range Compression (WDRC) Devices", Ear Hear, 22, pp.516~527 (2001)
- Kiessling J, "Adaptive fitting of hearing instruments by category loudness scaling (ScalAdapt)", Scand Audiol, 25, pp.153~160 (1996)
- Killion M, "The 2 types of sensorineural hearing loss. Loudness and intelligibility considerations", Hear J, 46(11), pp.31~34 (1993)
- Lybarger SF, "(July 3, 1944). U.S. Patent Application SN 543. 278. In: Hearing Aids", pp.236~ (2001), Thieme
- Lybarger SF, "2 cc coupler curves to insertion gain curves: Caculated and experimental results", Hear Instrum, 37, pp.36~40 (1986)
- McCandless GA, "Prescription of gain", output (POGO) for hearing aids, 1983, pp.34(1), 16~21
- Muller TF, "Effect of release time on preferred gain and speech acoustics", J Am Acad Audiol, 15(9), pp.605~615 (2004)
- Neuman AC, "Effect of release time in compression hearing aids: paired-comparison judgments of quality", J Acoust Soc Am, 98, pp.3182~3187 (1995)
- Schwartz D, "Hearing aid selection for severeto- profound hearing loss", Hear J, 41(2), pp.13~17 (1988)
- Souza PE, "The contribution of amplitude envelope cues to sentence identification in young and aged listeners", Ear Hear, 22, pp.112~119 (2001)
- Souza PE, "Multichannel compression, temporal cues, and audibility", J Speech Lang Hear Res, 41, pp.315~326 (1998)
- Tasell DJ, "Hearing loss, speech, and hearing aids", J Speech Lang Hear Res, 36, pp.228~244 (1993)