Purpose: This study aimed to report the development of Hearing Aid Gain for Korean Hearing Impaired version 2.0 (HAG-K v2.0), the Korean-type hearing aid fitting formula to improve the satisfaction of hearing aids and the communication ability of the Korean hearing impaired. Methods: HAG-K v2.0 was compared to NAL-NL2 with real-ear insertion gain (REIG) of the Korean hearing impaired, which was produced by considering most comfortable level and uncomfortable level, the levels and spectra of Korean conversational speech, band importance function, and preferred gain. Results: When REIG produced from HAG-K v2.0 was compared to NAL-NL2, it resulted low at HTL 40 and 80 dB HL and the compression threshold of HAG-K v2.0 was higher in all HTL compared to NAL-NL2. And the compression ratio was high at HTL 40 dB HL for NAL-NL2 and at 80 dB HL for HAG-K v2.0. Conclusion: HAG-K v2.0 developed in this study is the initial version of the Korean-type hearing aid fitting formula considering the characteristics of Korean conversational speech levels, spectra and preferred gain. With the systematic corrections and supplements for HAG-K v2.0 in the future, the Korean hearing impaired would benefit from this formula in electroacoustic control of the hearing aids.
Abstract
Purpose: This study aimed to report the development of Hearing Aid Gain for Korean Hearing Impaired version 2.0 (HAG-K v2.0), the Korean-type hearing aid fitting formula to improve the satisfaction of hearing aids and the communication ability of the Korean hearing impaired. Methods: HAG-K v2.0 was compared to NAL-NL2 with real-ear insertion gain (REIG) of the Korean hearing impaired, which was produced by considering most comfortable level and uncomfortable level, the levels and spectra of Korean conversational speech, band importance function, and preferred gain. Results: When REIG produced from HAG-K v2.0 was compared to NAL-NL2, it resulted low at HTL 40 and 80 dB HL and the compression threshold of HAG-K v2.0 was higher in all HTL compared to NAL-NL2. And the compression ratio was high at HTL 40 dB HL for NAL-NL2 and at 80 dB HL for HAG-K v2.0. Conclusion: HAG-K v2.0 developed in this study is the initial version of the Korean-type hearing aid fitting formula considering the characteristics of Korean conversational speech levels, spectra and preferred gain. With the systematic corrections and supplements for HAG-K v2.0 in the future, the Korean hearing impaired would benefit from this formula in electroacoustic control of the hearing aids.
참고문헌 (25)
- Aazh, H., "The accuracy of matching target insertion gains with open-fit hearing aids", American Journal of Audiology, 21(2), pp.175~180 (2012)
- 방어지니, "A Study on the Preferred Real-Ear Insertion Gain of Multi-Channel Hearing Aid for the Korean with Sensorineural Hearing Loss", Audiology and Speech Research, 16(2), pp.85~94 (2020), 한국청각언어재활학회
- Barker, C., "Client preferences for compression threshold in single-channel wide dynamic range compression hearing aids", Ear and Hearing, 20(2), pp.127~139 (1999)
- Barker, C., "Fitting low ratio compression to people with severe and profound hearing losses", Ear and Hearing, 22(2), pp.130~141 (2001)
- Boike, K. T., "Effect of compression ratio on speech recognition and speech-quality ratings with wide dynamic range compression amplification", Journal of Speech, Language, and Hearing Research, 43(2), pp.456~468 (2000)
- Byrne, D., "The National Acoustic Laboratories’(NAL)new procedure for selecting the gain and frequency response of a hearing aid", Ear and Hearing, 7(4), pp.257~265 (1986)
- Byrne, D., "NAL-NL1procedure for fitting nonlinear hearing aids : characteristics and comparisons with other procedures", Journal of the American Academy of Audiology, 12(1), pp.37~51 (2001)
- Cox, R. M., "Using loudness data for hearing aid selection: The IHAFF approach", The Hearing Journal, 48(2), pp.10~ (1995)
- 한우재, "Preferred Compression Threshold and Release Time in Quiet and Noisy Conditions for Elderly Korean Hearing Aid Users", Journal of Audiology & Otology, 21(3), pp.133~139 (2017), 대한청각학회
- 한영권, "A Study on the Korean Conversation Speech Level and Spectrum in Sound-Treated Environment", Audiology and Speech Research, 16(2), pp.133~139 (2020), 한국청각언어재활학회
- Electroacoustics–Hearing Aids–Part 15: Methods for Characterising Signal Processing in Hearing Aids with a Speech-Like Signal, "International Electrotechnical Commission", International Electrotechnical Commission, ~, pp.IEC 60118-15:2012 (2012)
- 정지행, "다채널 보청기의 해제시간에 따른 무의미음절인지도와 선호도의 변화", Audiology and Speech Research, 14(4), pp.250~258 (2018), 한국청각언어재활학회
- 진인기, "The Band-Importance Function for the Korean Standard Sentence Lists for Adults", Journal of Audiology & Otology, 20(2), pp.80~84 (2016), 대한청각학회
- 진인기, "Comparison of a Hearing Aid Fitting Formula Based on Korean Acoustic Characteristics and Existing Fitting Formulae", Audiology and Speech Research, 13(3), pp.216~221 (2017), 한국청각언어재활학회
- Johnson, E. E., "A comparison of gain for adults from generic hearing aid prescriptive methods: impacts on predicted loudness, frequency bandwidth, and speech intelligibility", Journal of the American Academy of Audiology, 22(7), pp.441~459 (2011)
- Keidser, G., "The NALNL2 Prescription Procedure", Audiology Research, 1(1), pp.e24~ (2011)
- Kiessling, J., "Adaptive fitting of hearing instruments by category loudness scaling(ScalAdapt)", Scandinavian Audiology, 25(3), pp.153~160 (1996)
- Killion, M., "The 3 types of sensorineural hearing loss:Loudness and intelligibility considerations", The Hearing Journal, 46(11), pp.31~36 (1993)
- 김시온, "다채널 보청기의 압축역치에 따른 자음인지와 음질의 변화", Audiology and Speech Research, 15(1), pp.23~29 (2019), 한국청각언어재활학회
- 이경원, "한국 난청인을 위한 보청기 이득의 제안", Audiology and Speech Research, 7(2), pp.119~123 (2011), 한국청각언어재활학회
- 이경원, "한국 단음절어의 주파수중요기능 연구", Audiology and Speech Research, 8(1), pp.24~33 (2012), 한국청각언어재활학회
- Lippmann, R. P., "Study of multichannel amplitude compression and linear amplification for persons with sensorineural hearing loss", The Journal of the Acoustical Society of America, 69(2), pp.524~534 (1981)
- Noh, H., "Cross-language identification of long-term average speech spectra in Korean and English: toward a better understanding of the quantitative difference between two languages", Ear and Hearing, 33(3), pp.441~443 (2012)
- 박유진, "건청인과 감각신경성난청 성인의 청력역치에 따른 음량증가의 변화", Audiology and Speech Research, 9(1), pp.25~32 (2013), 한국청각언어재활학회
- Souza, P. E., "Effects of compression on speech acoustics, intelligibility, and sound quality", Trends in Amplification, 6(4), pp.131~165 (2002)