In line with the requirement of appropriate protocol support for such mission-critical wireless sensor network (WSN) applications as patient monitoring, we investigate the framework for designing medium access control (MAC) schemes. The data traffic in medical systems comes with inherent traffic heterogeneity as well as strict requirement of reliability according to the varied extents of devise-wise criticality in separate cases. This implies that the quality-of-Service (QoS) issues are very distinctly delicate requiring specialized consideration. Besides, there are features in such systems that can be exploited during the design of a MAC scheme. In a monitoring or routine surveillance application, there are degrees of regularity or predictability in traffic as coordinated from a node of central control. The coordinator thus takes on the role of marshaling the resources in a neighborhood of nodes deployed mostly for upstream traffic; in a collision-free scheme, it schedules the time slots for each superframe based on the QoS specifications. In this preliminary study, we identify the key artifacts of such a MAC scheme. We also present basic performance issues like the impact of superframe length on delay incurred, energy efficiency achieved in the network operation as obtained in a typical simulation setup based on this framework.

Abstract

In line with the requirement of appropriate protocol support for such mission-critical wireless sensor network (WSN) applications as patient monitoring, we investigate the framework for designing medium access control (MAC) schemes. The data traffic in medical systems comes with inherent traffic heterogeneity as well as strict requirement of reliability according to the varied extents of devise-wise criticality in separate cases. This implies that the quality-of-Service (QoS) issues are very distinctly delicate requiring specialized consideration. Besides, there are features in such systems that can be exploited during the design of a MAC scheme. In a monitoring or routine surveillance application, there are degrees of regularity or predictability in traffic as coordinated from a node of central control. The coordinator thus takes on the role of marshaling the resources in a neighborhood of nodes deployed mostly for upstream traffic; in a collision-free scheme, it schedules the time slots for each superframe based on the QoS specifications. In this preliminary study, we identify the key artifacts of such a MAC scheme. We also present basic performance issues like the impact of superframe length on delay incurred, energy efficiency achieved in the network operation as obtained in a typical simulation setup based on this framework.

참고문헌 (15)

  1. S. Park, "Enhancing the quality of life through wearable technology", IEEE Engineering in Medicine and Biology Magazine, 22(3), pp.41~48 (2003)
  2. J. Ko, "Wireless sensor networks for healthcare", IEEE Proceedings (2010)
  3. H. Alemdar, "Wireless sensor networks for healthcare: A survey", Computer Networks, (54), pp.2688~2710 (2010)
  4. M. Chen, "Body area networks: a survey", Mobile Networks and Applications, 1~23 (2010)
  5. B. Latr'e, "A survey on wireless body area networks", Wireless Networks, ~ (2010)
  6. A. Bachir, "MAC essentials for wireless sensor networks", IEEE Communications Surveys and Tutorials, 12(2) (2010)
  7. K. Park, "IEEE 802.11 WLAN for medical-grade QoS", Proc. of the 1st ACM international workshop on Medical-grade wireless networks, pp.3~8 (2009)
  8. N. Timmons, "Analysis of the performance of IEEE 802.15. 4 for medical sensor body area networking", in Sensor and Ad Hoc Communications and Networks, 2004 (IEEE SECON '04). 2004 First Annual IEEE Communications Society Conference on, pp.16~24 (2004)
  9. "Part 15.4: wireless medium access control (MAC) and physical layer (PHY) specifications for low-rate wireless personal area networks (LR-WPANs)", IEEE Computer Society, ~ (2003)
  10. H. Li, "An ultra-low-power medium access control protocol for body sensor network", in Engineering in Medicine and Biology Society, 2005 (IEEE-EMBS '05). 27th Annual International Conference of the, pp.2451~2454 (2005)
  11. N. Golmie, "Performance analysis of low rate wireless technologies for medical applications", Computer Communications, 28(10), pp.1266~1275 (2005)
  12. D. Cavalcanti, "Performance analysis of 802.15. 4 and 802.11 e for body sensor network applications", in 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007), pp.9~14 (2007)
  13. B. Raman, "Censor networks: a critique of sensor networks", ACM SIGCOMM Computer Communication Review archive, 38, pp.75~78 (2008)
  14. S. Arnon, "A comparative study of wireless communication network configurations for medical applications", IEEE Wireless Communications, 10(1), pp.56~61 (2003)
  15. T. Penzel, "Acquisition of biomedical signals databases", IEEE Eng Med Biol Mag, 20(3), pp.25~32 (2001)