Effect of Different Types of Firefighter Station Uniforms on Wearer Mobility using Range of Motion and Electromyography Evidence

0

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류생활과학

초록

This study analyzed and compared wearer mobility for different types of clothing that also included the potential to develop firefighter station uniforms using range of motion (ROM) and electromyography (EMG). This study focused on a comparison of wearer mobility affected by different materials and shapes of the station uniforms worn under firefighter turnout gear. Japanese standard uniform (UNI), stretch-wear (ST), and compression-wear (CP) were used as station uniforms for the experiment. This study analyzed wearer movements and quantified ROM and EMG. In addition, the subjective evaluation of wearer mobility and comfort were assessed for comparisons. Nine healthy male students participated in the experiment. Wearer mobility was analyzed using ROM and EMG data obtained by measuring five motions; in addition, subjective evaluations were also obtained. As compared with the standard station uniform, ROM increased 6.8% and 7.2% due to stretch-wear and compression-wear. The benefits of wearing stretch material or compression material to improve muscle performance (such as reduced percent of maximum voluntary contraction) were not proven. Differences between materials and designs influenced subjective wearer comfort. In particular, the wearing of compression materials was shown best in terms of wearer comfort that may also allow greater wearer mobility.

Abstract

This study analyzed and compared wearer mobility for different types of clothing that also included the potential to develop firefighter station uniforms using range of motion (ROM) and electromyography (EMG). This study focused on a comparison of wearer mobility affected by different materials and shapes of the station uniforms worn under firefighter turnout gear. Japanese standard uniform (UNI), stretch-wear (ST), and compression-wear (CP) were used as station uniforms for the experiment. This study analyzed wearer movements and quantified ROM and EMG. In addition, the subjective evaluation of wearer mobility and comfort were assessed for comparisons. Nine healthy male students participated in the experiment. Wearer mobility was analyzed using ROM and EMG data obtained by measuring five motions; in addition, subjective evaluations were also obtained. As compared with the standard station uniform, ROM increased 6.8% and 7.2% due to stretch-wear and compression-wear. The benefits of wearing stretch material or compression material to improve muscle performance (such as reduced percent of maximum voluntary contraction) were not proven. Differences between materials and designs influenced subjective wearer comfort. In particular, the wearing of compression materials was shown best in terms of wearer comfort that may also allow greater wearer mobility.

참고문헌 (39)

  1. Performance effects of wearing compression garment (SKINS™) during exercise and recovery, "Argus, C. K.", Centre for Sport and Exercise Science, The Waikato Institute of Technology, ~ (2005)
  2. Bakri, I., "Effects of firefighters’ self-contained breathing apparatus’ weight and its harness design on the physiological and subjective responses", Ergonomics, 55(7), pp.782~791 (2012)[DOI]
  3. Born, D. P., "A novel compression garment with adhesive silicone stripes improves repeated sprint performance-a multi-experimental approach on the underlying mechanisms", BMC Sports Science, Medicine and Rehabilitation, 6(1), pp.21~ (2014)[DOI]
  4. Chou, C., "Physiological and subjective responses to cooling devices on firefighting protective clothing", European Journal of Applied Physiology, 104(2), pp.369~374 (2008)[DOI]
  5. Doan, B. K., "Evaluation of a lower-body compression garment", Journal of Sport Sciences, 21(8), pp.601~610 (2003)[DOI]
  6. Eglin, C. M., "Physiological responses of fire-fighter instructors during training exercises", Ergonomics, 47(5), pp.483~494 (2004)[DOI]
  7. Graveling, R., "Design of UK firefighter clothing", Proceedings of Nokobetef, European conference on protective clothing, pp.277~280 (2000), Arbetslivsinstitutet
  8. Gregory, D. E., "The effect of fatigue on trunk muscle activation patterns and spine postures during simulated firefighting tasks", Ergonomics, 51(7), pp.1032~1041 (2008)[DOI]
  9. INGVAR HOLMÉR, "Protective clothing and heat stress", Ergonomics, 38(1), pp.166~182 (1995), Informa UK Limited[DOI]
  10. Hooper, A. J., "An evaluation of physiological demands and comfort between the use of conventional and lightweight self-contained breathing apparatus", Applied Ergonomics, 32(4), pp.399~406 (2001)
  11. Huck. J., "Restriction to movement in firefighter protective clothing : Evaluation of alternative sleeves and liners", Applied Ergonomics, 22(2), pp.91~100 (1991)
  12. 임민정, "기능성 아웃도어 웨어의 등산용 남성 재킷 프로토타입 디자인", 복식, 61(4), pp.152~168 (2011), 한국복식학회
  13. Ishiigaki, M., "Evaluation of motion adaptability during dressing", undressing by emg-friction between materials in layered wearing as a factor, 2007, pp.58(9), 569~577
  14. Relationship between clothes wearing feeling and clothes pressure of aged woman’s jacket, "Iwasaki, K.", Bulletin of the Tokyo Metropolitan Industrial Technology Research Institute, 6~9 (2006)
  15. 김영희, "A Functional Design of Fire Fighter Coveralls", 한국의류학회지, 26(12), pp.1739~1748 (2002), 한국의류학회
  16. 김영희, "여성복 상의 원형의 기능성 향상을 위한 소매산 및 소매통 변화에 관한 연구-동작 가동 범위(ROM) 측정을 중심으로-", 한국의류학회지, 33(8), pp.1181~1189 (2009), 한국의류학회
  17. 구영석, "컴프레션웨어(Compression Wear)의 운동성능 및 근기능에 미치는 영향", 한국염색가공학회지, 23(1), pp.60~68 (2011), 한국염색가공학회
  18. 김지현, "여자경찰 기동대원들의 경찰보호복에 대한 착용실태 및 만족도에 관한 연구", 복식문화연구, 22(2), pp.326~338 (2014), 복식문화학회[DOI]
  19. 권명숙, "의용소방대용 근무복 소재의 역학적 특성 및 쾌적성에 관한 연구", 복식, 57(3), pp.53~62 (2007), 한국복식학회
  20. Lee, J. Y., "What do firefighters desire from the next generation of personal protective equipment? Outcomes from an international survey", Industrial Health, 53(5), pp.434~444 (2015)[DOI]
  21. Malley, K. S., "Effects of fire fighting uniform(modern, modified modern, and traditional)design changes on exercise duration in New York City firefighters", Journal of Occupational and Environmental Medicine, 41(12), pp.1104~1115 (1999)
  22. McCarthy, L., "The application of phase change material in fire fighter protective clothing", Fire Technology, 48(4), pp.841~864 (2012)[DOI]
  23. McLellan, T. M., "Heat stress while wearing long pants or shorts under firefighting protective clothing", Ergonomics, 47(1), pp.75~90 (2004)[DOI]
  24. "Enprotex magazine" (2014)[URL]
  25. Nakahashi, M., "The new physiological clothing" (1997), Nankodo
  26. Nakahashi, M., "Relationship between wearing time period and moving time quantity of fireman’s turnouts based on a scenario of fire", Japan Society of Physical Anthropology, 8(2), pp.39~45 (2003)
  27. Park, J. Y., "Anthropometric fit evaluation of firefighters’ uniform pants: A sex composition", International Journal of Industrial Ergonomics, 56, pp.1~8 (2016)[DOI]
  28. 석혜정, "의용소방대의 근무복 개발에 관한 연구", Human Ecology Research, 44(7), pp.63~72 (2006), 대한가정학회
  29. Shimosaka, C., "Evaluation of motion adaptability of clothing of young and elderly women-In the case of layering with different materials", Japan Society of Home Economics, 59(12), pp.989~998 (2008)[DOI]
  30. Shimosaka, C., "Ease of sleeve width and motion adaptability of blouses – evaluation by using sensory evaluation clothing pressure and EMG", Japan Society of Home Economics, 59(1), pp.29~35 (2008)[DOI]
  31. Son, S. Y., "Evaluation of the effects of various clothing conditions on firefighter mobility and the validity of those measurements made", Journal of the Human-Environment System, 13(1), pp.15~24 (2010)[DOI]
  32. Son, S. Y., "Occupational stress and strain in relation to personal ptrotective equipment of Japanese firefighters assessed by a questionnaire", Industrial Health, 51(2), pp.214~444 (2013)[DOI]
  33. Tamura, T., "The science of clothing environment" (2004), Kenpakusha
  34. Tochihara, Y., "Environmental ergonomics XI", pp.137~139 (2005), Lund University
  35. Troynikove, O., "Evaluation of surface characteristics of inner layer fabrics suitable for structural firefighters’ clothing", Textile Research Journal, 82(10), pp.1014~1025 (2012)[DOI]
  36. Watanabe, K., "Motion analysis of elderly women’s dressing for clothing design", Japan Society of Home Economics, 60(5), pp.473~480 (2009)[DOI]
  37. Watanabe, S., "Research on heatproof performance of fire protective clothing", Seni Gakkaishi, 66(2), pp.49~55 (2010)
  38. White, M. K., "Physiological and subjective responses to working in disposable protective coveralls and respirators commonly used by the asbestos abatement industry", American Industrial Hygiene Association Journal, 50(6), pp.313~319 (1989)[DOI]
  39. Yamato, Y., "The influence of ease of clothing for human body on the thermal insulation of clothing ensembles", Journal of the Japan Research Association for Textile End-uses, 51(4), pp.281~292 (2010)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (11건)