본문 바로가기
KERD
논문KCI 등재

Effect of the Mg Ion Containing Oxide Films on the Biocompatibility of Plasma Electrolytic Oxidized Ti-6Al-4V

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기계공학

초록

In this study, we prepared magnesium ion containing oxide films formed on the Ti-6Al-4V using plasma electrolytic oxidation (PEO) treatment. Ti–6Al–4V surface was treated using PEO in Mg containing electrolytes at 270V for 5 min. The phase, composition and morphology of the Mg ion containing oxide films were evaluated with X-ray diffraction (XRD), Attenuated total reflectance Fourier transform infrared (ATR-FTIR) and filed-emission scanning electron microscopy (FE-SEM) with energy dispersive X-ray spectrometer (EDS). The biocompatibility of Mg ion containing oxide films was evaluated by immersing in simulated body fluid (SBF). According to surface properties of PEO films, the optimum condition was formed when the applied was 270 V. The PEO films formed in the condition contained the properties of porosity, anatase phase, and near 1.7 Ca(Mg)/P ratio in the oxide film. Our experimental results demonstrate that Mg ion containing oxide promotes bone like apatite nucleation and growth from SBF. The phase and morphologies of bone like apatite were influenced by the Mg ion concentration.

Abstract

In this study, we prepared magnesium ion containing oxide films formed on the Ti-6Al-4V using plasma electrolytic oxidation (PEO) treatment. Ti–6Al–4V surface was treated using PEO in Mg containing electrolytes at 270V for 5 min. The phase, composition and morphology of the Mg ion containing oxide films were evaluated with X-ray diffraction (XRD), Attenuated total reflectance Fourier transform infrared (ATR-FTIR) and filed-emission scanning electron microscopy (FE-SEM) with energy dispersive X-ray spectrometer (EDS). The biocompatibility of Mg ion containing oxide films was evaluated by immersing in simulated body fluid (SBF). According to surface properties of PEO films, the optimum condition was formed when the applied was 270 V. The PEO films formed in the condition contained the properties of porosity, anatase phase, and near 1.7 Ca(Mg)/P ratio in the oxide film. Our experimental results demonstrate that Mg ion containing oxide promotes bone like apatite nucleation and growth from SBF. The phase and morphologies of bone like apatite were influenced by the Mg ion concentration.

참고문헌 (22)

  1. T. Albrektsson, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man", Acta Orthop. Scand, 52, pp.155~170 (1981)
  2. C. Yao, "Anodization : a promising nano-modification technique of titanium implants for orthopedic applications", J. Nanosci. Nanotechnol, 6, pp.2682~2692 (2006)
  3. B. D. Ratner, "Titanium in medicine: material science, surface science, engineering, biological responses and medical application", pp.10~ (2001), Springer
  4. M. P. Thomsen, "Morphological studies on titanium implant inserted in rabbit knee-joint", Adv. Biomater, 7, pp.87~92 (1987)
  5. K. D. Groot, "Plasma sprayed coatings of hydroxyapatite", J. Biomed. Mater. Res, 7, pp.1375~1381 (1987)
  6. Y. H. Jeong, "Electrochemical behavior of nano and femtosecond laser textured titanium alloy for implant surface modification", J. Nanosci. Nanotechnol, 11, pp.1581~1584 (2011)
  7. K. Lee, "Transmission elecrtron microscopy application for the phenomena of hydroxyapatite precipitation in micropore-structured Ti alloy", Surf. Interface Anal, 44, pp.1492~1496 (2012)
  8. S. Stojadinovic, "Characterization of the plasma electrolytic oxidation of titanium in sodium metasilicate", Appl. Surf. Sci, 265, pp.226~233 (2013)
  9. S. Durdu, "Characterization of AZ31 Mg Alloy coated by plasma electrolytic oxidation", Vacuum, 88, pp.130~133 (2013)
  10. A. Polat, "Influence of sodium silicate concentration on structural and tribological properties of micro arc oxidation coatings on 2017A aluminum alloy substrate", J. Alloys Compd, 504, pp.519~526 (2010)
  11. A. L. Yerokhin, "Charaterisation of oxide films produced by plasma electrolytic oxidation of a Ti-6Al-4V alloy", Surf. Coat. Tech, 130, pp.195~206 (2000)
  12. K. H. Nan, "Strontium doped hydroxyapatite film formed by micro-arc oxidation", Mater. Sci. Eng. C, 29, pp.1554~1558 (2009)
  13. W. H. Song, "Biomimetic apatite coatings on micro-arc oxidized titania", Biomaterials, 25, pp.3341~3349 (2004)
  14. S. Durdu, "Characterization and formation of hydroxyapatite on Ti-6Al-4V coated by plasma electrolytic oxidation", J. Alloys Compd, 551, pp.422~429 (2013)
  15. M. S. Kim, "One-step approach for nano-crystalline hydroxyapatite coating on titanium via micro-arc oxidation", Electrochem. Commun, 9, pp.1886~1891 (2007)
  16. T. Hanawa, "Biofunctionalization of titanium for dental implant", Jpn. Dent. Sci. Rev, 46, pp.93~101 (2010)
  17. Y. M. Ko, "Effect of Mg ion on formation of bone-like apatite on the plasma modified titanium surface", Surf. Coat. Tech, 228, pp.S404~S407 (2013)
  18. R. C. Barik, "Corrosion, erosion and erosion-corrosion performance of plasma electrolytic oxidation (PEO) deposited Al2O3 coatings", Surf. Coat. Tech, 199, pp.158~167 (2005)
  19. K. S. TenHuisen, "Effects of magnesium on the formation of calcium-deficient hydroxyapatite form CaHPO4·2H2O and Ca4(PO4)2O", J. Biomed. Mater. Res, 36, pp.306~314 (1997)
  20. M. T. Pham, "Promoted hydroxyapatite nucleation on titanium ion-implanted with sodium", Thin Solid Films, 379, pp.50~56 (2000)
  21. M. P. Staiger, "Magnesium and its alloys as orthopedic biomaterials:A review", Biomaterials, 27, pp.1728~1734 (2006)
  22. P. N. De Aza, "Bioceramic-simulated body fluid interfaces: pH and its influence of hydroxyapatite formation", J. Mater. Sci., Mater. Med, 7, pp.399~402 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (17건)