The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 hr-1 which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

Abstract

The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 hr-1 which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

참고문헌 (11)

  1. Targo Kalamees, "Air tightness and air lea kages of new lightweight single-family det ached houses in Estonia", Building and Environment, 42, pp.2369~2377 (2007)
  2. Jurgen Schnieders and Andreas Hermelink, "CEPHEUS results: measurements and occupants’ satisfaction provide eviden ce for Passive Houses being an option for sustainable building", Energy Policy, 34(2), pp.151~171 (2006)
  3. M. Airaksinen, "Microbial contaminati on of indoor air due to leakages from cr awl space: a field stud", Indoor Air, 14(1), pp.55~64 (2004), Indoor Air
  4. 박원석, "신축공동주택의 기밀성능 실 측에 관한 연구", 한국생태환경건축학회논문집, 3(3), pp.43~50 (2003), 한국생태환경건축학회
  5. 이광호, 문장수, 박용후, 김상민, 손장열, "초고층 주상복합아파트의 기밀 성능 및 연돌 효과 특성에 관한 연구", 대한건축학회논문집, 21(12), pp.279~286 (2005), 대한건축학회
  6. 유헌영, "바람에 의한 침기량 변화가 주택 의 난방부하에 및 IAQ에 미치는 영향", 박사, pp.1991
  7. Alan Mier, "Infiltration: Just ACH50 Divided by 20?, Home Energy Magazine" (1994)
  8. "ASHRAE Standard 119-1988", Air Leaka ge Performance for Detached Single Family Residential buildings, 1998, ~
  9. "The Energy Conservatory, Minneapolis Blower Door Operation Manul for Model 3 systems" (1993), The Energy Conservatory
  10. 박원석, "주거용건물의 기밀성능 기준설정 을 위한 침기량 실측에 관한 연구", 석사, pp.2003
  11. 신우철, 백남춘, 윤종호, "고기밀 고단열 주택의 기밀성능에 관한 실험적 연구", 한국태양에너지학회 논문집, 25(4), pp.61~68 (2005), 한국태양에너지학회