Infiltration characteristics of airborne particulate matter had been investigated in real-life for about 90 days over 2 years in a Korean apartment building where a 3-person household had lived and the exclusive private area was 84.9 m2. Airtightness was measured by fan depressurization, and the ACH50 was 2.41 times per hour. In and outdoor particle concentrations were measured by optical particle counters. Infiltration factors and filtration efficiencies of the house, which reflect the removal of outdoor particles penetrating building envelope and the deposition inside a building, were obtained from data screened based on an empirical evaluation process. Infiltration factor of fine particles showed a range from about 42% at 0.4 m/s of wind speed to 72% at 4.2 m/s of wind speed with closed windows and doors. Filtration efficiency was like a MERV 13 grade filter with an open window outside at a balcony at low outdoor wind speed under 1 m/s. The grade decreased to MERV 11 by opening another outside window at the other balcony. Filtration efficiencies decreased as much as 29% in average at a range of 0.3~2.5 μm.

Abstract

Infiltration characteristics of airborne particulate matter had been investigated in real-life for about 90 days over 2 years in a Korean apartment building where a 3-person household had lived and the exclusive private area was 84.9 m2. Airtightness was measured by fan depressurization, and the ACH50 was 2.41 times per hour. In and outdoor particle concentrations were measured by optical particle counters. Infiltration factors and filtration efficiencies of the house, which reflect the removal of outdoor particles penetrating building envelope and the deposition inside a building, were obtained from data screened based on an empirical evaluation process. Infiltration factor of fine particles showed a range from about 42% at 0.4 m/s of wind speed to 72% at 4.2 m/s of wind speed with closed windows and doors. Filtration efficiency was like a MERV 13 grade filter with an open window outside at a balcony at low outdoor wind speed under 1 m/s. The grade decreased to MERV 11 by opening another outside window at the other balcony. Filtration efficiencies decreased as much as 29% in average at a range of 0.3~2.5 μm.

참고문헌 (21)

  1. Abt, E., "Relative contribution of outdoor and indoor particle sources to indoor concentrations", Environmental Science & Technology, 34(17), pp.3579~3587 (2000)
  2. ASHRAE, "Standard 52.2-2007. Method of testing general ventilation air cleaning devices for removal efficiency by particle size", American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc, ~ (2007)
  3. ASTM, "E779-10. Standard test method for determining air leakage rate by fan pressurization", American Society of Testing and Materials, ~ (2010)
  4. 배귀남, "실내 에어로졸의 거동 및 제어 연구동향", 실내환경 및 냄새 학회지, 16(2), pp.99~112 (2017), 한국냄새환경학회[DOI]
  5. Chao, C. Y., "Penetration coefficient and deposition rate as a function of particle size in non-smoking naturally ventilated residences", Atmospheric Environment, 37(30), pp.4233~4241 (2003)
  6. Fisk, W. J., "Performance and cost of particle air filtration technologies", Indoor Air, 12(4), pp.223~234 (2002)
  7. Hinds, W. C., "Aerosol Technology : Properties, behavior, and measurement of airborne particles" (1998), John Wiley and Sons Inc
  8. Ji, J. H., "Size distributions of suspended fine particles during cleaning in an office", Particle and Aerosol Research, 14(2), pp.25~33 (2018)
  9. 지준호, "실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정", PARTICLE AND AEROSOL RESEARCH, 9(2), pp.39~50 (2013), 한국입자에어로졸학회[DOI]
  10. Jo, J. H., "Airtightness data of Korean apartment buildings", Korean Institute of Architectural Sustainable Environment and Building Systems, 9(3), pp.40~48 (2015)
  11. Joo, S. W., "Characteristics of indoor particulate matter concentrations by size at an apartment house during dusty-day", Particle and Aerosol Research, 15(1), pp.37~44 (2019)
  12. KIAEBS, "KIAEBS C-1. Building Airtightness Criteria", Korean Institute of Architectural Sustainable Environment and Building Systems, ~ (2013)
  13. Annual report of air quality in Korea 2017, "KME", Korean Ministry of Environment, ~ (2018)
  14. Long, C. M., "Using time-and size-resolved particulate data to quantify indoor penetration and deposition behavior", Environmental Science & Technology, 35(10), pp.2089~2099 (2001)
  15. Malik, N., "Field studies of dependence of air infiltration on outside temperature and wind", Energy and Buildings, 1(3), pp.281~292 (1978)
  16. Nazaroff, W. W., "Indoor particle dynamics", Indoor Air, 14(ppl.7), pp.175~183 (2004)
  17. Population and Housing Census of 2016 <Registered Census Method Results>, "Statistics Korea", ~ (2016)
  18. Wallace, L., "Indoor particles : a review", Journal of the Air & Waste Management Association, 46(2), pp.98~126 (1996)
  19. 이수환, "실내 미세먼지 농도 예측을 위한 침입계수 및 침착률 산정방법에 관한 연구", 대한건축학회논문집 구조계, 33(11), pp.35~42 (2017), 대한건축학회[DOI]
  20. 윤효정, "한국 성인의 평일 및 주말의 시간활동 양상 평가", 실내환경 및 냄새 학회지, 16(2), pp.182~186 (2017), 한국냄새환경학회[DOI]
  21. 윤재옥, "신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구", KIEAE Journal, 13(3), pp.27~32 (2013), 한국생태환경건축학회[DOI]