본문 바로가기
KERD
논문KCI 등재

Zero Energy School 구현을 위한 고등학교 건물의 에너지 소비특성 사례분석

Case Analysis of Energy Consumption Characteristics of High School Facilities for Zero Energy School Realization

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

The characteristics of energy consumption of school buildings considering their distinctive functional schedule (including summer and winter vacation) differ from those of residential and business buildings. In order to build zero-energy schools, the introduction of an energy-saving plan and renewable energy system that reflect the actual energy use of school buildings should be considered. However, ECO2, the only evaluation tool used for zero-energy building certification, does not reflect the actual energy use of schools. In this study, we analyzed characteristics of energy consumption of ‘S’ high school located in Jincheon, Chungcheongbuk-do, based on measurement data received from a remote monitoring system and city gas usage. Based on the results, the measured actual energy consumption and the energy consumption evaluated in the ‘Building Energy Efficiency Certification’ were compared. The energy-use intensity of the actual energy consumption was 125.9 kWh/m2yr, which was 1++ grade. The energy use intensity evaluated through this certification was 188.9 kWh/m2yr, which was 1+ grade. Concerning energy consumption by use, the actual energy consumption in decreasing order was heating (31%), ventilation (25%), cooling (23%), lighting (15%), and hot water supply (6%; excluding cooking), and electric appliance and plug load (37%). Cooling was the largest unit according to “Building Energy Efficiency Certification” evaluation criteria at 36%, followed by heating (31%), lighting (11%), ventilation (10%), and hot water (9%). The results differed considerably from the actual energy consumption and energy consumption evaluated through ECO2. The results would likely be distorted if an energy reduction measure and a zero energy implementation plan were established based on the results.

Abstract

The characteristics of energy consumption of school buildings considering their distinctive functional schedule (including summer and winter vacation) differ from those of residential and business buildings. In order to build zero-energy schools, the introduction of an energy-saving plan and renewable energy system that reflect the actual energy use of school buildings should be considered. However, ECO2, the only evaluation tool used for zero-energy building certification, does not reflect the actual energy use of schools. In this study, we analyzed characteristics of energy consumption of ‘S’ high school located in Jincheon, Chungcheongbuk-do, based on measurement data received from a remote monitoring system and city gas usage. Based on the results, the measured actual energy consumption and the energy consumption evaluated in the ‘Building Energy Efficiency Certification’ were compared. The energy-use intensity of the actual energy consumption was 125.9 kWh/m2yr, which was 1++ grade. The energy use intensity evaluated through this certification was 188.9 kWh/m2yr, which was 1+ grade. Concerning energy consumption by use, the actual energy consumption in decreasing order was heating (31%), ventilation (25%), cooling (23%), lighting (15%), and hot water supply (6%; excluding cooking), and electric appliance and plug load (37%). Cooling was the largest unit according to “Building Energy Efficiency Certification” evaluation criteria at 36%, followed by heating (31%), lighting (11%), ventilation (10%), and hot water (9%). The results differed considerably from the actual energy consumption and energy consumption evaluated through ECO2. The results would likely be distorted if an energy reduction measure and a zero energy implementation plan were established based on the results.

참고문헌 (8)

  1. "Edu Now" (2021)[URL]
  2. 조두상, "학교건축물의 에너지소비 원단위화에 관한 연구 - 대구광역시 소재 초?중?고등학교를 대상으로 -", 대한건축학회논문집, 18(8), pp.209~216 (2002), 대한건축학회
  3. 윤종호, "전국 고등학교 시설의 에너지 사용실태 분석 연구", 한국태양에너지학회 논문집, 30(4), pp.55~62 (2010), 한국태양에너지학회
  4. 김강식, "고등학교 시설의 에너지 소비량특성에 관한 사례분석", 한국태양에너지학회 논문집, 31(5), pp.99~104 (2011), 한국태양에너지학회
  5. 김성범, "서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석", 한국태양에너지학회 논문집, 36(6), pp.61~69 (2016), 한국태양에너지학회
  6. Korea Institute of Energy Research, "The Technology Development and Demonstration Research for Jincheon Eco-Friendly Energy Town Construction", Ministry of Science, ICT and Future Planning, ~ (2017)
  7. Ministry of Land Infrastructure and Transport, "Regulations for Building Energy Efficiency Class Certification and Zero Energy Building Certification System-Attachment 3", Korea Energy Corporation, ~ (2021)