대형 하이브리드 트럭용 열전 무시동 공조시스템 성능 연구
Performance of Non-starting Conditioning System using Thermoelectric Modules for Hybrid Heavy Trucks
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
To reduce vehicle fuel consumption due to not only driving but also air conditioning, battery-operated non-starting conditioning systems with thermoelectric modules and without mechanical elements like compressors are being manufactured for use by hybrid heavy trucks in the near future. In this study, the voltage and current consumed by a thermoelectric module were measured to determine the required battery power, and the performance of the conditioning system with air temperature, and humidity of the inlet/outlet modules and inside/outside the cabin for a truck, was evaluated using experimental apparatus under actual conditions. The results showed that, the thermoelectric module can be continously operated for about 1.5 h using existing 24 V batteries. The coefficent of performance(COP) of the cooling and heating modes was calculated to be an average 0.8-1.32. As expected, the heating performance was 30% more efficient than the cooling performance, which is general characteristic of thermoelectric modules.
Abstract
To reduce vehicle fuel consumption due to not only driving but also air conditioning, battery-operated non-starting conditioning systems with thermoelectric modules and without mechanical elements like compressors are being manufactured for use by hybrid heavy trucks in the near future. In this study, the voltage and current consumed by a thermoelectric module were measured to determine the required battery power, and the performance of the conditioning system with air temperature, and humidity of the inlet/outlet modules and inside/outside the cabin for a truck, was evaluated using experimental apparatus under actual conditions. The results showed that, the thermoelectric module can be continously operated for about 1.5 h using existing 24 V batteries. The coefficent of performance(COP) of the cooling and heating modes was calculated to be an average 0.8-1.32. As expected, the heating performance was 30% more efficient than the cooling performance, which is general characteristic of thermoelectric modules.
참고문헌 (7)
- Won, S. I., "Freezing Engineering" (2003), Bosu-nggak
- 노건상, "자연 냉매를 이용하는 이원 냉동시스템의 성능 예측", 한국기계기술학회지, 12(3), pp.45~51 (2010), 한국기계기술학회
- Yang, D. U., "Experimental Study on Operating Characteristics of Anti-Start Air-Condition and Heating System Using Thermo Electric Element", KSAE Autumn Conference Proceedings, pp, pp.660~665 (2011)
- 김순호, "차량용 냉방시스템에의 열전소자 적용에 관한 연구", 한국동력기계공학회지, 12(4), pp.32~38 (2008), 한국동력기계공학회
- Majumdar, A., "Thermoelectricity in Semi-conductor Nanostructures", Sience, 303(777), pp.303~777 (2004)
- Kim, K. J., "The Efficiency of Thermoelectric Energy Conversion at High Power Electronics", KSME Autumn Conference, pp.1702~1706 (2011)
- Park, J. S., "A Study on Improve Efficiency and Cooling Performance of the LED Lighting using a Seebeck Effect of the Thermoelectric element", EMECSS Annual Autumn Conference, pp.1225~1227 (2012)