실제 건물 적용을 고려한 태양광열 및 공기열원 융복합 시스템의 동적 해석
Dynamic Analysis of the Integrated System using Photovoltaic-Thermal and Air Source Heat Pump Considering Real Building Application
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
As regulations on renewable energy are strengthened and zero-energy buildings are becoming mandatory, research on the commercialization of renewable energy for heating and cooling buildings is accelerating. However, geothermal, photovoltaic, and solar heat are mostly applied as single systems, and there are few cases in which the disadvantages of individual systems are overcome or where the advantages are maximized. The purpose of this study is to develop an analysis model that can respond stably to heating and cooling loads in buildings and to analyze system performance. To stabilize the control of cooling, heating, and hot water supply, the operation method is divided into four cycles. In seasons when cooling and heating loads are significantly decreased, heating and cooling are performed directly by the heat pump without using storage tanks. In addition, a case study using late-night power was conducted to investigate efficient electricity use. Without late-night power, the heat pump coefficient of performance (COP) during the heating period was 2.5 and the monthly average heat exchange rate (HER) was 240 kWh; meanwhile, the COP during the cooling period was 3.99 and the HER was 880 kWh. The energy self-sufficiency rate during the heating period was 2.02 times higher than the cooling period. However, as a result of using late-night power, the electricity rate and COP during heating decreased by 2.5% and 2.04%, respectively, and the COP during cooling increased by 0.1%. This study presents basic data for the implementation of renewable energy systems and the design of predictive models.
Abstract
As regulations on renewable energy are strengthened and zero-energy buildings are becoming mandatory, research on the commercialization of renewable energy for heating and cooling buildings is accelerating. However, geothermal, photovoltaic, and solar heat are mostly applied as single systems, and there are few cases in which the disadvantages of individual systems are overcome or where the advantages are maximized. The purpose of this study is to develop an analysis model that can respond stably to heating and cooling loads in buildings and to analyze system performance. To stabilize the control of cooling, heating, and hot water supply, the operation method is divided into four cycles. In seasons when cooling and heating loads are significantly decreased, heating and cooling are performed directly by the heat pump without using storage tanks. In addition, a case study using late-night power was conducted to investigate efficient electricity use. Without late-night power, the heat pump coefficient of performance (COP) during the heating period was 2.5 and the monthly average heat exchange rate (HER) was 240 kWh; meanwhile, the COP during the cooling period was 3.99 and the HER was 880 kWh. The energy self-sufficiency rate during the heating period was 2.02 times higher than the cooling period. However, as a result of using late-night power, the electricity rate and COP during heating decreased by 2.5% and 2.04%, respectively, and the COP during cooling increased by 0.1%. This study presents basic data for the implementation of renewable energy systems and the design of predictive models.
참고문헌 (12)
- Ministry of Trade, Industry and Energy, "Act on the Promotion of the Development, Use, and Diffusion of New And Renewable Energy", ~ (2021)
- 남유진, "태양열 및 지중열원을 이용한 히트펌프 시스템의 최적이용법에 관한 연구", 설비공학 논문집, 24(6), pp.509~514 (2012), 대한설비공학회[DOI]
- Mark Dannemand, "Performance of a demonstration solar PVT assisted heat pump system with cold buffer storage and domestic hot water storage tanks", Energy and Buildings, 188-189, pp.46~57 (2019), Elsevier BV[DOI]
- Ministry of land, Infrastructure and Transport, "Green Buildings Construction Support Act", ~ (2018)
- Sangmu Bae, "Performance Analysis of Integrated Photovoltaic-Thermal and Air Source Heat Pump System through Energy Simulation", Energies, 15(2), pp.528~ (2022), MDPI AG[DOI]
- Passive House Institute Korea, "Climate Data", ~ (2013)
- ASHRAE, "Ventilation for Acceptable Indoor Air Quality", Standard 62.1-2019, ~ (2019)
- ASHRAE, "Thermal Environmental Conditions for Human Occupancy", Standard 55-2020, ~ (2020)
- ASHRAE, "Energy standard for buildings except low-rise residential buildings", Standard 90.1-2019, ~ (2019)
- ASHRAE, "Heating, Ventilating, a ND Air-conditioning Applications" (2015)
- 남유진, "지역 기후 특성에 따른 지열시스템의 도입경제성 차이에 관한 연구", KIEAE Journal, 14(4), pp.127~131 (2014), 한국생태환경건축학회[DOI]
- Ministry of Land, Infrastructure and Transport, "Certification of Green Buildings", ~ (2021)