본문 바로가기
KERD
논문KCI 등재

넷-제로에너지주택의 공기열원 히트펌프시스템 동적거동 및 에너지성능 분석

Dynamic Behavior and Energy Performance Analysis of Air Source Heat Pump System in Net-Zero Energy House

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

Air-source heat pumps (ASHPs) have somewhat lower operating performance than ground- source heat pumps (GSHPs), but they have been reported to have low initial investment costs and a great energy-cost-saving effect due to the implementation of net-zero-energy houses. In this study, we analyzed the dynamic behavior and energy performance of equivalent ASHPs in existing low-energy houses installed with GSHPs of 9 kW using TRNSYS dynamic simulation. The house with a total floor area of 194 m2 was an all-electric house and domestic hot water, space heating, and cooling energy were supplied by the ASHP. To summarize the main results, first, the annual space heating and cooling energy supply of the ASHPs was 7,698 kWh and 2,226 kWh, respectively, and the annual heating COP and cooling EER were 3.4 and 3.1, respectively. Second, the total annual power consumption of the proposed model with ASHPs was 8,218 kWh and the annual power generation of the 6 kWp PV system was 8,682 kWh, which generated a surplus of 464 kWh, achieving net-zero energy. Third, the total annual electricity charge was 249,000 generated by ASHPs (proposal model) connected to the “residential service” grid of KEPCO, which was reduced by approximately 66% compared to the 736,000 generated by the GSHPs (existing model) linked to a “general service” grid.

Abstract

Air-source heat pumps (ASHPs) have somewhat lower operating performance than ground- source heat pumps (GSHPs), but they have been reported to have low initial investment costs and a great energy-cost-saving effect due to the implementation of net-zero-energy houses. In this study, we analyzed the dynamic behavior and energy performance of equivalent ASHPs in existing low-energy houses installed with GSHPs of 9 kW using TRNSYS dynamic simulation. The house with a total floor area of 194 m2 was an all-electric house and domestic hot water, space heating, and cooling energy were supplied by the ASHP. To summarize the main results, first, the annual space heating and cooling energy supply of the ASHPs was 7,698 kWh and 2,226 kWh, respectively, and the annual heating COP and cooling EER were 3.4 and 3.1, respectively. Second, the total annual power consumption of the proposed model with ASHPs was 8,218 kWh and the annual power generation of the 6 kWp PV system was 8,682 kWh, which generated a surplus of 464 kWh, achieving net-zero energy. Third, the total annual electricity charge was 249,000 generated by ASHPs (proposal model) connected to the “residential service” grid of KEPCO, which was reduced by approximately 66% compared to the 736,000 generated by the GSHPs (existing model) linked to a “general service” grid.

참고문헌 (11)

  1. 손병후, "단독주택 적용 지열 히트펌프 시스템의 성능 분석", 설비공학 논문집, 23(6), pp.392~399 (2011), 대한설비공학회
  2. 이철희, "저에너지주택내 지중순환수 조건 변화에 따른 지열 히트펌프의 동절기 성능평가", 신재생에너지, 11(3), pp.28~36 (2015), 한국신·재생에너지학회[DOI]
  3. 정선영, "제로에너지 솔라하우스(KIER ZeSH-II)의 에너지성능 측정 및 에너지자립도 분석", 대한건축학회논문집, 27(12), pp.307~314 (2011), 대한건축학회
  4. 이왕제, "제로에너지타운 내 주택 에너지 성능 평가에 관한 연구", 한국태양에너지학회 논문집, 35(2), pp.85~92 (2015), 한국태양에너지학회
  5. 백남춘, "실측데이터를 이용한 저에너지주택의 에너지성능평가", 설비공학 논문집, 27(7), pp.369~374 (2015), 대한설비공학회[DOI]
  6. 백남춘, "저에너지주택의 지열히트펌프시스템 냉․난방 성능분석", 설비공학 논문집, 28(10), pp.387~393 (2016), 대한설비공학회[DOI]
  7. 임희원, "넷 제로에너지주택 실증사례 분석에 관한 연구", KIEAE Journal, 18(5), pp.41~46 (2018), 한국생태환경건축학회[DOI]
  8. "Engineering Product Data Book, LG Total HVAC Solution Provider (P", No. : MFL66101116), 2019
  9. TRNSYS 17, "A TRaNsient SYstem Simulation program, Solar Energy Laboratory", University of Wisconsin-Madison, ~ (2010)
  10. "T.E.S.S. Component Libraries v.17.01 for TRNSYS v17.0 and the TRNSYS Simulation Studio, Parameter", Input, Thermal Energy System Specialists, LLC, pp.2004, ~
  11. 임희원, "창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가", 설비공학 논문집, 30(4), pp.159~166 (2018), 대한설비공학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (14건)