정밀 마찰측정을 위한 이중 캔틸레버 구조 마찰시험기의설계에 관한 연구
A Study on the Design of a Double Cantilever Structure Friction Tester for Precision Friction Measurement
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A precision tribometer consisting of a cantilever was designed to measure frictional forces in the micro-Newton range. As frictional forces are measured based on the bending of the cantilever, vibration of the cantilever is the most significant factor affecting the quality of the friction measurement. Therefore, improved design of the tribometer with double cantilevers and a connecting plate that united the two cantilevers mechanically was suggested. For the verification of the modified design of the tribometer, numerical analysis and experiments were conducted. Examination using the finite element method revealed that the tribometer with a double cantilever and a connecting plate exhibited faster damping characteristics than the tribometer with a single cantilever. In the experiment, effectiveness of the double cantilever and connecting plate for vibration reduction was also confirmed. Vibration of the tribometer with double cantilever decreased eight times faster than that of the tribometer with a single cantilever. The faster damping of the double cantilever design is attributed to the mechanical interaction at the contacting surfaces between the cantilever and the connecting plate. Tribotesting using the tribometer with a single cantilever resulted in random fluctuation of frictional forces due to the stickslip behavior. However, using the tribometer with a double cantilever and connecting plate for the tribotest gave relatively uniform and steady measurement of frictional forces. Increased stiffness owing to using a double cantilever and mechanical damping of the connecting plate were responsible for the stable friction signal.
Abstract
A precision tribometer consisting of a cantilever was designed to measure frictional forces in the micro-Newton range. As frictional forces are measured based on the bending of the cantilever, vibration of the cantilever is the most significant factor affecting the quality of the friction measurement. Therefore, improved design of the tribometer with double cantilevers and a connecting plate that united the two cantilevers mechanically was suggested. For the verification of the modified design of the tribometer, numerical analysis and experiments were conducted. Examination using the finite element method revealed that the tribometer with a double cantilever and a connecting plate exhibited faster damping characteristics than the tribometer with a single cantilever. In the experiment, effectiveness of the double cantilever and connecting plate for vibration reduction was also confirmed. Vibration of the tribometer with double cantilever decreased eight times faster than that of the tribometer with a single cantilever. The faster damping of the double cantilever design is attributed to the mechanical interaction at the contacting surfaces between the cantilever and the connecting plate. Tribotesting using the tribometer with a single cantilever resulted in random fluctuation of frictional forces due to the stickslip behavior. However, using the tribometer with a double cantilever and connecting plate for the tribotest gave relatively uniform and steady measurement of frictional forces. Increased stiffness owing to using a double cantilever and mechanical damping of the connecting plate were responsible for the stable friction signal.
참고문헌 (14)
- 김현준, "Nano-scale Friction : A Review", International Journal of Precision Engineering and Manufacturing, 10(2), pp.141~151 (2009), 한국정밀공학회
- Malek, C. K., "Applications of LIGA technology to precision manufacturing of high-aspect-ratio micro-components and -systems: a review", Microelectron. J., 35, pp.131~143 (2004)[DOI]
- Shikida, M., "Surface roughness of single-crystal silicon etched by TMAH solution", Sens. Actuator A-Phys., 90, pp.223~231 (2001)[DOI]
- Patton, S. T., "Failure mechanisms of a MEMS actuator in very high vacuum", Tribol. Int., 35, pp.373379~ (2002)
- Bhushan, B., "Principles an Applications of Tribology, Chap. 12", pp.812~ (1999), John Wiley & Sons, Inc.
- Czichos, H., "Multilaboratory tribotesting: Results from the Versailles Advanced Materials and Standards programme on wear test methods", Wear, 114, pp.109~130 (1987)[DOI]
- Khadem, M., "Ultra-thin nano-patterned wearprotective diamond-like carbon coatings deposited on glass using a C60 ion beam", Carbon, 80, pp.534~543 (2014)[DOI]
- 김혜균, "기판 종류에 따른 물 윤활 특성 및 나노 입자의 영향", 한국트라이볼로지학회지, 33(6), pp.245~250 (2017), 한국트라이볼로지학회[DOI]
- Sader, J., E, "Calibration of rectangular atomic force microscope cantilevers", Rev. Sci. Instrum., 70, pp.3967~ (1999)[DOI]
- Varenberg, M., "An improved wedge calibration method for lateral force in atomic force microscopy", Rev. Sci. Instrum., 74, pp.3362~ (2003)[DOI]
- Celis, J.-P., "Testing Tribocorrosion of Passivating Materials Supporting Research and Industrial Innovation: A Handbook" (2011), Maney Publishing
- Kim, H.-J., "Precise tribometer operated with low load, KR Patent No. 10-1793593", Kyungpook National University, ~ (2017)
- Kim, H.-J., "Molecular dynamics simulation of atomic-scale frictional behavior of corrugated nano-structured surfaces", Nanoscale, 4, pp.3937~3944 (2012)[DOI]
- Muser, M. H., "Nature of Mechanical Instabilities and Their Effect on Kinetic Friction", Phys. Rev. Lett., 89, pp.224301~ (2002)[DOI]