본문 바로가기
KERD
논문KCI 등재

공기식 태양열 집열기 내 사분원 저항체 설치 조건에 따른 대류 열전달 및 압력강하 특성 분석

Analysis of Convective Heat Transfer and Pressure Drop Characteristics with Various Installation Conditions of a Quarter-Circle Obstacle in an Air-Based Solar Collector

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

Air-based solar collectors are renewable systems that produce heated air using solar thermal energy. However, the thermal efficiency of these systems must be increased because of the low thermal conductivity of air. In this study, the heat transfer and pressure drop characteristics of a developed air-based solar collector with quarter-circle-shaped obstacles on the upper and lower surfaces of an air channel were investigated. Computational fluid dynamics (CFD) was used to analyze the effects of the obstacle installation conditions on the heat transfer and pressure drop. The quarter-circle-shaped obstacle produced a 2.53-fold increase in heat transfer; however, the friction factor also increased 41.38 times. Therefore, the performance factor, which considers heat transfer enhancement and pressure drop, was also evaluated. The performance factor was highest at a Reynolds number of 3000 with installation conditions of e/H = 0.10 and P/e = 40, yielding a value of 1.16. Furthermore, empirical correlations for the Nusselt number and friction factor were developed based on the Reynolds number and obstacle installation conditions. The average absolute percentage errors between the CFD results and the from the correlations were 2.98% and 7.5%, respectively, indicating high agreement between the values.

Abstract

Air-based solar collectors are renewable systems that produce heated air using solar thermal energy. However, the thermal efficiency of these systems must be increased because of the low thermal conductivity of air. In this study, the heat transfer and pressure drop characteristics of a developed air-based solar collector with quarter-circle-shaped obstacles on the upper and lower surfaces of an air channel were investigated. Computational fluid dynamics (CFD) was used to analyze the effects of the obstacle installation conditions on the heat transfer and pressure drop. The quarter-circle-shaped obstacle produced a 2.53-fold increase in heat transfer; however, the friction factor also increased 41.38 times. Therefore, the performance factor, which considers heat transfer enhancement and pressure drop, was also evaluated. The performance factor was highest at a Reynolds number of 3000 with installation conditions of e/H = 0.10 and P/e = 40, yielding a value of 1.16. Furthermore, empirical correlations for the Nusselt number and friction factor were developed based on the Reynolds number and obstacle installation conditions. The average absolute percentage errors between the CFD results and the from the correlations were 2.98% and 7.5%, respectively, indicating high agreement between the values.

관련 논문AI추천

태양열 공기식 집열기 내 저항체 설치 위치 및 형상에 따른 열전달 및 압력강하 특성에 대한 CFD 해석문광암, 안건용, 안병화, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2025 · 제45권 제3호공기식 태양광/열 집열기 내 반원 난류 촉진제 형상조건과 유동 조건에 따른 열전달 성능 평가김성빈, 김준엽, 안병화, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2022 · 제42권 제3호공기식 태양광/열 집열기 내 저항체 형상조건과 유동 조건에 따른 열전달 성능 및 압력강하 분석김성빈, 김영복, 김준엽, 손창효, 안병화, 윤정인, 최광환한국태양에너지학회 · 한국태양에너지학회 논문집2022 · 제42권 제1호공기식 태양광/ 열 집열기 내 비균일 삼각 단면을 갖는 난류 촉진제에 의한 열전달 및 압력강하 성능 분석김성빈, 문광암, 안병화, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2023 · 제43권 제4호CFD를 활용한 태양열 공기가열기 내 사각저항체 설치 조건에 따른 열전달 및 압력강하에 관한 연구김영복, 손창효, 윤정인, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2019 · 제39권 제1호공기식 태양광/열 집열기 내 공기층에서 비균일 단면을 갖는 돌출부 설치 조건에 따른 전열 성능에 관한 분석김영복, 문광암, 손창효, 윤정인, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2021 · 제41권 제1호

이 간행물의 다른 논문 (17건)