공기식 태양광/열 집열기 내 저항체 형상조건과 유동 조건에 따른 열전달 성능 및 압력강하 분석
Heat Transfer Performance and Pressure Drop Analysis According to Shape Conditions of Turbulent Promoters and Flow Conditions in Air-Type PV/T Collectors
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Air-type photovoltaic and thermal (PV/T) has a lower thermal capacity than liquid-type one; therefore, studies are being conducted turbulence promoters to improve heat transfer in a duct. This study aims to evaluate heat transfer performance and pressure drop while changing the increasing and decreasing ratio of turbulence promoters by using computational fluid dynamics (CFD). The increasing and decreasing ratio is a concept focused on increasing the height of turbulence promoters n times from the first row to the last row to generate high air temperatures at the outlet side. As a result, the difference in heat transfer performance according to the increasing and decreasing ratio was minimal; however, it was confirmed that the pressure drop increased in the order of 1.3, 1.2, and 1.1, because the increased resistance to air flow due to increased installation height of the turbulent promoters. Accordingly, it was found that the thermohydraulic performance parameter (THPP) increased in the order of 1.1, 1.2, and 1.3. Because of the changes for various shape conditions were not taken into account, additional consideration is required to select suitable conditions.
Abstract
Air-type photovoltaic and thermal (PV/T) has a lower thermal capacity than liquid-type one; therefore, studies are being conducted turbulence promoters to improve heat transfer in a duct. This study aims to evaluate heat transfer performance and pressure drop while changing the increasing and decreasing ratio of turbulence promoters by using computational fluid dynamics (CFD). The increasing and decreasing ratio is a concept focused on increasing the height of turbulence promoters n times from the first row to the last row to generate high air temperatures at the outlet side. As a result, the difference in heat transfer performance according to the increasing and decreasing ratio was minimal; however, it was confirmed that the pressure drop increased in the order of 1.3, 1.2, and 1.1, because the increased resistance to air flow due to increased installation height of the turbulent promoters. Accordingly, it was found that the thermohydraulic performance parameter (THPP) increased in the order of 1.1, 1.2, and 1.3. Because of the changes for various shape conditions were not taken into account, additional consideration is required to select suitable conditions.
참고문헌 (19)
- 문광암, "공기식 태양광", 열 집열기 내 공기층에서 비균일 단면을 갖는 돌출부 설치 조건에 따른 전열 성능에 관한 분석, 2021, pp.41(1), 79~92[DOI]
- Yu, J. S., "Effect of Triangular Baffle Arrangement on Heat Transfer Enhancement of Air-Type PVT Collector", Sustainability, 12(18), pp.7469~ (2020)
- 최휘웅, "공기식 태양광", 열 시스템 공기채널 내 여러 저항체설치에 따른 전열성능에 관한 CFD 해석, 2018, pp.38(2), 33~43[DOI]
- Choi, H. U., "Performance Evaluation of PV", T Air Collector Having a Single-Pass Double-Flow Air Channel and Non-Uniform Cross-Section Transverse Rib, 2020, pp.13(9), 2203~
- 유지숙, "타공 베플이 적용된 공기식 PVT 컬렉터의 실험을 통한 열·전기성능 평가 연구", 한국태양에너지학회 논문집, 41(1), pp.25~34 (2021), 한국태양에너지학회[DOI]
- 김상명, "실험에 의한 공기식 PVT 컬렉터의 열 ‧ 전기 성능에 관한 연구", 한국태양에너지학회 논문집, 39(2), pp.23~32 (2019), 한국태양에너지학회[DOI]
- Delisle, V., "Performance Assessment of a New Air-based Building-integrated Photovoltaic Thermal Solar Collector", 33rd European Photovoltaic Solar Energy Conference and Exhibition, pp.2590~2595 (2017)
- Jha, P., "An Experimental Study of a Photovoltaic Thermal Air Collector (PVTAG): A Comparison of a Flat and the Wavy Collector", Applied Thermal Engineering, 163, pp.1~13 (2019)
- Othman, M. Y., "Performance studies on a finned double-pass photovoltaic-thermal (PV", T) solar collector, 2007, pp.209, 43~49
- Kumar, R., "Performance evaluation of a double pass PV", T solar air heater with and without fins, 2011, pp.31, 1402~1410
- Anil Singh Yadav, J. L., "CFD (Computational Fluid Dynamics) based Heat Transfer and Fluid Flow Analysis of a Solar Air Heater Provided with Circular Transverse Wire Rib Roughness on the Absorber Plate", Energy, 55, pp.1127~1142 (2013)
- Anil Singh Yadav, J. L., "CFD based Thermo-hydraulic Performance Analysis of an Artificially Roughened Solar Air Heater Having Equilateral Triangular Sectioned Rib Roughness on the Absorber Plate", International Journal of Heat and Mass Transfer, 70, pp.1016~1039 (2014)
- ASHRAE Standard 93, "Method of Testing to Determine the Thermal Performance of Solar Collectors", American Society of Heat, Refrigeration and Air Conditioning Engineers, ~ (2003)
- ANSYS Fluent, "Version 17.2", ANSYS Inc, ~ (2016)
- Singh, S., "CFD (Computational Fluid Dynamics) Investigation on Nusselt Number and Friction Factor of Solar Air Heater Duct Roughened with Non-uniform Cross-section Transverse Rib", Energy, 84, pp.509~517 (2015)
- Kumar, B. V., "A Performance Evaluation of a Solar Air Heater Using Different Shaped Ribs Mounted on the Absorber Plate-A Review", Energies, 11, pp.3104~ (2018)
- Choi, H. U., "CFD Analysis on the Heat Transfer and Fluid Flow of Solar Air Heater having Transverse Triangular Block at the Bottom of Air Duct", Energies, 13(5), pp.1099~ (2020)
- Ansys Inc, "ANSYS Fluent 12.0 User’s Guide", Fluent Inc, ~ (2009)
- Webb, R. L., "Forced Convection Heat Transfer in Helically Rib-roughened Tubes", International Journal of Heat and Mass Transfer, 23, pp.1127~1136 (1980)