본문 바로가기
KERD
논문KCI 등재

코로나 방전에 의한 방진/의료용 마스크 여과재의 기능화 가공

Functional Finishing of Nonwoven Filter for Dust-proof/Medical Masks by Corona Discharging Treatment

0

조회

0

다운로드

7

인용

0

참고문헌

키워드

초록

In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV,0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

Abstract

In this study, 25gsm melt-blown polypropylene nonwoven for dust-proof/medical masks was finished by the corona discharging treatment. The influence of corona discharging parameters on the filtration efficiency was investigated. Several parameters such as discharging voltage, discharging speed, distance to discharging wire and configuration of discharging system had an effect on filtration efficiency, while the parameters had no effect on breathing resistance. Optimum corona discharging conditions are as follows: Wires were installed on the upper part of the nonwoven and paper pipe was installed on the lower part of the nonwoven having a distance of 5cm. The sequence of wire voltages was +60 kV, +60 kV,0, -60 kV, and -60 kV. The discharging voltage and speed were 60 kV and 30m/min respectively. The nonwoven treated by corona discharging at the optimum condition showed a filtration efficiency of 80% or more, which is suitable for dust-proof/medical masks.

참고문헌 (19)

  1. R. S. Sigmond, "Electric Breakdown and Discharges in Gases, In NATO ASI Ser", pp.1~64 (1983), Plenum
  2. E. Occhiello, "International Encyclopedia of Composites", pp.1~390 (1991), VCH
  3. H. W. Kim, "Modification of Polymer Surface by Corona Discharge and the Subsequent Graft Polymerization of Acry lamide", Textile Coloration and Finishing (J. Korean Soc. Dye. and Finish.), 5(1), pp.26~ (1993)
  4. H. W. Kim, "Study on the Gradient Surface of Carboxylic Acid Group Using Corona Discharge Treatment and Subsequent Graft Polymerization", Textile Coloration and Finishing (J. Korean Soc. Dye. and Finish.), 6(2), pp.17~ (1994)
  5. B. O. Lee, "Multi-Functional Finish of Polyester and P", C Blend Fabrics by Corona Discharge(Ⅰ) -Flame-Retardant and Sanitary Finish, 1997, pp.9(2), 1~
  6. B. O. Lee, "Multi-Functional Finish of Polyester and P", C Blend Fabrics by Corona Discharge(Ⅱ) -Multifunctional Finish, 1997, pp.9(3), 1~
  7. 이재달, "고성능 멜트블로운 부직포 복합필터 개발", 한국염색가공학회지, 17(2), pp.40~45 (2005), 한국염색가공학회
  8. 서은덕, "방염용 실리카의 고정화를 위한 아마인유의 저온플라즈마처리", 한국염색가공학회지, 24(4), pp.313~320 (2012), 한국염색가공학회
  9. 신현세, "멜트블로운 부직포 제조공정이 유흡착포의 특성에 미치는 영향", 한국염색가공학회지, 21(6), pp.22~28 (2009), 한국염색가공학회
  10. A. Kravtsov, "The Electret Effect in Polypropylene Fibers Treated in a Corona Discharge", Advances in Polymer Technology, 19(4), pp.312~ (2000)
  11. B. Łowkis, "Electret Properties of Polypropylene Fabrics", J. Electrostatics, 51, pp.232~ (2001)
  12. B. Tabti, "Factors that Influence the Corona Charging of Fibrous Dielectric Materials Original Research Article", J. Electrostatics, 67, pp.193~ (2009)
  13. K. K. Oh, "A Study on the Filtration Characteristics of the Electrostatically Charged Nonwoven Polypropylene Media", J. Korean Ind. Eng. Chem, 12(4), pp.434~ (2001)
  14. A. F. Robert, "The Effect of Particle Charge on Penetration in an Electret Filter", IEEE Transactions on Industry Applications, 24, pp.4~ (1998)
  15. J. D. Jung, "Korea Pat. 1011657630000", ~ (2012)
  16. Z. Zuo, "Performance Evaluation of Filtering Facepiece Respirators using Virus Aerosols", American J. Infection Control, 41(1), pp.80~ (2013)
  17. D. H. Han, "Protection against Aerosols by Particulate Respirators and Fit Performance", Korean J. Environmental Health, 27(2), pp.30~ (2001)
  18. 한돈희, "방진마스크의 안면부 누설률에 관한 연구", 한국환경보건학회지, 30(5), pp.432~439 (2004), 한국환경보건학회
  19. 송인희, "멜트블로운 부직포의 후가공 공정에 의한 흡음재의 제조와 특성", 한국염색가공학회지, 23(4), pp.304~311 (2011), 한국염색가공학회

관련 논문AI추천