Experimental and CFD Simulations of Polluted Air Behavior in Rectangular Tunnels
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
The objective of this study is to investigate the flow characteristics of polluted air behavior in rectangular tunnels using a PIV system and a commercial CFD program. The PIV experiments are simulated by using the olive oil as the tracer particles in scaled rectangular tunnels. Each model has one of four different outlet vents, each dimensionless L/H ratio of which is 0, 0.375, 0.75 and 1.125, respectively as the locations of each outlet are away from the vertical centerline through the inlet. A commercial CFD program, ANSYS CFX, was used to examine the velocity fields and the pressure distributions in numerical simulations. The kinematic viscosity of the air flow of 1.51× 10^(-5) ㎡/s and the flow velocity of 0.3 m/s at the inlet are given under the same conditions in order to analyze the polluted air flow characteristics experimentally and computationally. This study is considered to examine the effect of the outlet locations in the naturally ventilated tunnel models.
Abstract
The objective of this study is to investigate the flow characteristics of polluted air behavior in rectangular tunnels using a PIV system and a commercial CFD program. The PIV experiments are simulated by using the olive oil as the tracer particles in scaled rectangular tunnels. Each model has one of four different outlet vents, each dimensionless L/H ratio of which is 0, 0.375, 0.75 and 1.125, respectively as the locations of each outlet are away from the vertical centerline through the inlet. A commercial CFD program, ANSYS CFX, was used to examine the velocity fields and the pressure distributions in numerical simulations. The kinematic viscosity of the air flow of 1.51× 10^(-5) ㎡/s and the flow velocity of 0.3 m/s at the inlet are given under the same conditions in order to analyze the polluted air flow characteristics experimentally and computationally. This study is considered to examine the effect of the outlet locations in the naturally ventilated tunnel models.
참고문헌 (11)
- Wu, Y, "Control of smoke flow in tunnel fires using longitudinal ventilation systems-a study of the critical velocity", Fire Safety Journal, 35, pp.363~390 (2000)
- Dr. Marco Bettenlini, "CFD for tunnel safety", Fluent Users' Meeting (2001)
- Nuri, Y, "Experimental and numerical simulation of fire in a scaled underground station", World Academy of Science, Engineering and Technology, 40, pp.309~314 (2008)
- C.C. Hwang, "The critical ventilation velocity in tunnel fires-a computer simulation", Fire Safety Journal, 40, pp.213~244 (2005)
- C.C. Hwang, "Experimental Study of thermally generated reverse stratified layers in a fire tunnel", Combust Flame, 66, pp.171~180 (1986)
- Sang Kyoo Park, "PIV measurement of the flow field in rectangular tunnel", 한국마린엔지니어링학회지, 32(6), pp.886~892 (2008), 한국마린엔지니어링학회
- 이용호, "Flow Field Analysis of Smoke in a Rectangular Tunnel", 한국마린엔지니어링학회지, 33(5), pp.679~685 (2009), 한국마린엔지니어링학회
- M. Raffel, "Particle Image Velocimetry, A Practical Guide", pp.88~123 (1998), Springer
- Dantec Dynamics, "FlowManger software and introduction to PIV: 2D PIV Installation and User's Guide", pp.33~118 (2000)
- R. J. Adrian, "Twenty years of particle image velocimetry", Experiments in Fluids, 39, pp.159~169 (2005)
- Yakhot, V, "Renormalization group analysis of turbulence", Journal of Scientific Computing, 3, pp.3~51 (1986)