본문 바로가기
KERD
논문KCI 등재

가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구

ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY

1

조회

0

다운로드

1

인용

0

참고문헌

주제분류치의학

초록

Abstract

Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

참고문헌 (39)

  1. "Prosthodontic Treatment for partiallyEdentulous Patients" (1978), MosbyCo
  2. "Elastomeric impression materials:effect of bulk on accuracy", 41, pp.304~307 (1979)
  3. "Long-term dimensional stability of threecurrent elastomers", 10, pp.323~325 (1983)
  4. "Time-dependent accuracy of elastomerimpression materials", 45, pp.329~333 (1981)
  5. "Factors that affectthe accuracy and dimentional stabilityof the mercaptan rubber-base impressionmaterials", 10, pp.525~535 (1960)
  6. "The accuracy of stonedies made from rubber impression materials", 24, pp.337~386 (1970)
  7. "Evaluation of the methods for dislodgingthe impression tray affecting the dimensionalaccuracy of the abutments in a completedental arch cast", 61, pp.54~58 (1989)
  8. "Council on Dental Materials", pp.595~596 (1990), Vinyl polysiloxaneimpression materials
  9. "Custom impression trays with a new hypoallergenicmaterial", pp.572~573 (1994)
  10. "Development of dentulous stock trays forkoreans", 5(3), pp.85~124 (1995)
  11. "A study on thefitness of stock tray in korean adults", 27(2), pp.131~140 (1989)
  12. "Astudy on the fitness of dentulous stock tray462designed for koreans", 7(1), pp.193~209 (1997)
  13. "10thMeeting of the International College ofProsthodontists", abstract (2003), Development ofadjustable dental impression trays
  14. "Impression materials andtechniques used for cast restoration ineight states", 100, pp.696~699 (1980)
  15. "Restorative Dental Materials" (1985), Mosby Co
  16. "Making a custom trayfor elastomeric impression materials withouta primary cast", pp.569~571, Making a custom trayfor elastomeric impression materials withouta primary cast
  17. "The impression tray - an importantfactor in impression precision", 27, pp.146~ (1977)
  18. "Custom inpression trays part 1:Mechanicalproperties", 71, pp.31~34 (1994)
  19. "Determiningthe accuracy of stock and custom trayimpression", casts, 1998, pp.25, 645~648
  20. "Theeffect of tray selection on the accuracy ofelastomeric impression materials", 63, pp.12~15 (1990)
  21. "The effect of usingcustom or stock trays on the accuracyof gypsum casts", 9, pp.367~373 (1996)
  22. "A laboratory study of dimensionalchanges for three elastomeric impressionmaterials using custom and stock trays", 4, pp.398~404 (1996)
  23. "Laser digitization of caststo determine the effect of tray selection andcast formation technique on accuracy", 87, pp.204~209 (2002)
  24. "Evaluation of dental arch reproductionusing three-dimensional optical digitization", 90, pp.434~440 (2003)
  25. "Comparison of impressionmade in perforate and nonperforated rimlocktrays", 27, pp.494~500 (1972)
  26. "The influence of stone castspoured from irreversible hydrocolloid impressions", 54, pp.383~388 (1985)
  27. "Accuracy of stone casts produced by perforatedtrays an nonperforated trays", 53, pp.347~350 (1985)
  28. "Dimensionalstability of elastomeric impression materialsin custom-made and stock trays", 52, pp.514~517 (1984)
  29. "Accuracy of fourtypes of rubber impression materials comparedwith time of pour and a repeatpour of models", 53, pp.484~490 (1985)
  30. "Accuracy of a hydrophilicirreversible hydrocolloid", siliconeimpression material, 1986, pp.55, 304~308
  31. "Effect of materialbulk and undercuts on the accura-463cy of impression materials", 54, pp.791~794 (1985)
  32. "Phillips’science of dentalmaterials", st louis 1996, pp.170~ (1996)
  33. "Accuracyof stone cast produced by perforated traysand nonperforated trays", 53, pp.347~350 (1985)
  34. "A study of distortionand surface hardness of improved artificialstone casts", 36, pp.373~381 (1976)
  35. "Theeffects of custom tray material on theaccuracy of master casts", 7, pp.106~110 (1998)
  36. "Accuracy of three polyvinyl siloxane putty-wash impression techniques", 83, pp.161~165 (2000)
  37. "Dimensionalstability of elastomeric impression materialsin custom-made and stock trays", 52, pp.514~519 (1984)
  38. "Developmentand evaluation of a new 3-D digitizationand computer graphic system to studythe anatomic tissue and restoration surfaces", 23, pp.25~34 (1996)
  39. "Use of ascanning laser three-dimensional digitizerto evaluate dimensional accuracy ofdental impression materials", 68, pp.229~235

관련 논문AI추천