Purpose: This study evaluated the effect of nonthermal plasma treatment on the bond strength of autopolymerizing relining resin to the injection molded thermoplastic denture base resins (TDBRs) with different surface treatments. Materials and methods: Acrylic Resin (Acrytone), Polyester (Estheshot-Bright), Polyamide (Valplast) and Polypropylene (Weldenz) were subjected to various surface treatments: No treatment, Nonthermal plasma, Sandblasting, Sandblasting and nonthermal plasma. Specimens were bonded using an autopolymerizing relining resin. Shear bond strength was tested using universal testing machine with crosshead speed of 1 mm/min. Statistical analysis by two-way analysis of variance with Tukey’ test post hoc was used. Results: Acrytone showed significantly higher shear bond strength value among other TDBR group while Weldenz had the lowest. The sandblasting and nonthermal plasma condition had significantly higher shear bond strength value in all of the resin groups (P < .05). Conclusion: The use of nonthermal plasma treatment showed limited effect on the shear bond strength between TDBRs and relining resin, and combination of nonthermal plasma and sandblasting improved the shear bond strength between TDBR and reline material.
Abstract
Purpose: This study evaluated the effect of nonthermal plasma treatment on the bond strength of autopolymerizing relining resin to the injection molded thermoplastic denture base resins (TDBRs) with different surface treatments. Materials and methods: Acrylic Resin (Acrytone), Polyester (Estheshot-Bright), Polyamide (Valplast) and Polypropylene (Weldenz) were subjected to various surface treatments: No treatment, Nonthermal plasma, Sandblasting, Sandblasting and nonthermal plasma. Specimens were bonded using an autopolymerizing relining resin. Shear bond strength was tested using universal testing machine with crosshead speed of 1 mm/min. Statistical analysis by two-way analysis of variance with Tukey’ test post hoc was used. Results: Acrytone showed significantly higher shear bond strength value among other TDBR group while Weldenz had the lowest. The sandblasting and nonthermal plasma condition had significantly higher shear bond strength value in all of the resin groups (P < .05). Conclusion: The use of nonthermal plasma treatment showed limited effect on the shear bond strength between TDBRs and relining resin, and combination of nonthermal plasma and sandblasting improved the shear bond strength between TDBR and reline material.
참고문헌 (22)
- Fueki K, "Part II: Material properties and clinical features of non-metal clasp dentures", J Prosthodont Res, 58, pp.71~84 (2014)[DOI]
- Takabayashi Y, "Characteristics of denture thermoplastic resins for non-metal clasp dentures", Dent Mater J, 29, pp.353~361 (2010)[DOI]
- Hamanaka I, "Bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins", J Prosthodont Res, 61, pp.67~72 (2017)[DOI]
- Hargreaves AS, "Nylon as a denture-base material", Dent Pract Dent Rec, 22, pp.122~128 (1971)
- Stafford GD, "The use of nylon as a denture-base material", J Dent, 14, pp.18~22 (1986)[DOI]
- Parvizi A, "Comparison of the dimensional accuracy of in- jection-molded denture base materials to that of conventional pressure-pack acrylic resin", J Prosthodont, 13, pp.83~89 (2004)[DOI]
- Yunus N, "Some flexural properties of a nylon denture base polymer", J Oral Rehabil, 32, pp.65~71 (2005)[DOI]
- Katsumata Y, "Mechanical characterization of a flexible nylon denture base material", Bull Kanagawa Dent Col, 35, pp.177~182 (2007)
- Roodabeh Koodaryan, "Effect of surface treatment methods on the shear bond strength of autopolymerized resin to thermoplastic denture base polymer", The Journal of Advanced of Prosthodontics, 8(6), pp.504~510 (2016), 대한치과보철학회[DOI]
- Kim JH, "Evaluation of adhesion of reline resins to the thermoplastic denture base resin for non-metal clasp denture", Dent Mater J, 33, pp.32~38 (2014)[DOI]
- Brown HR, "Adhesion of polymers", MRS Bull, 21, pp.24~27 (1996)
- Katsumata Y, "Bonding strength of autopo- lymerizing resin to nylon denture base polymer", Dent Mater J, 28, pp.409~418 (2009)[DOI]
- Nishigawa G, "Plasma treatment increased shear bond strength between heat cured acrylic resin and self-curing acrylic resin", J Oral Rehabil, 30, pp.1081~1084 (2003)[DOI]
- Hoffmann C, "Cold Atmospheric Plasma: methods of production and application in dentistry and oncology", Med Gas Res, 3, pp.21~ (2013)[DOI]
- Chen M, "Surface modification of several dental substrates by non-thermal, atmospheric plasma brush", Dent Mater, 29, pp.871~880 (2013)[DOI]
- Yang YZ, "Preparation of graded porous titanium coatings on titanium implant materials by plasma spraying", J Biomed Mater Res, 52, pp.333~337 (2000)[DOI]
- Fischer H, "Improvement of the long-term adhesive strength between metal stem and polymethylmethacrylate bone cement by a silica", silane interlayer system, 2001, pp.57, 413~418
- Kim JH, "Evaluation of adhesion of reline resins to the thermoplastic denture base resin for non-metal clasp denture", Dent Mater J, 33, pp.32~38 (2014)[DOI]
- Naichuan Su, "The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resin", The Journal of Advanced of Prosthodontics, 7(3), pp.214~223 (2015), 대한치과보철학회[DOI]
- Ozden N, "Time-related wettability characteristic of acrylic resin surfaces treated by glow discharge", J Prosthet Dent, 82, pp.680~684 (1999)[DOI]
- Jokinen V, "Oxygen and nitrogen plasma hydrophilization and hydrophobic recovery of polymers", Biomicrofluidics, 6, pp.16501~16510 (2012)[DOI]
- Ozcan C, "Influence of oxygen plasma modification on surface free energy of PMMA films and cell attachment", Macromol Symp, 269, pp.128~137 (2008)[DOI]