임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY

2

조회

0

다운로드

1

인용

0

참고문헌

주제분류치의학

초록

Abstract

Statement of problem : Since the concept of osseointegrated dental implant by Bra。- nemark et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate(p<0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p<0.05). 3. Cone screw groups have the highest initial stability and final stability. 4. All groups are decreased tightening rate after repeated loading.

참고문헌 (31)

  1. "Osseointegration and its experimentalbackground", 50, pp.399~410
  2. "Long-term follow-up study of osseointegrated implants inthe treatment of totally edentulous jaws", 5(4), pp.347~59 (1990)
  3. "Prosthetic considerationsfor the utilization of osseo-integrated fixturesin the partially edentulous arch", 1(1), pp.39~45 (1986)
  4. "Osseointegrated implantsfor single-tooth replacement:a prospective5-year multicenter study", 11(4), pp.450~5 (1996)
  5. "Clinical complications of osseointegratedimplants", 81(5), pp.537~52 (1999)
  6. "Tissue-integratedprosthesis complications", 7(4), pp.477~84
  7. "Prosthodontic problems and limitationsassociated with osseointegration", 79(1), pp.74~8 (1998)
  8. "The external hexagonal interfaceand screw-joint stability: A primer onthreaded fasteners in implant dentistry", 23, pp.91~104 (2000)
  9. "Nonlinearcontact analysis of preload in dental implantscrews", 10(3), pp.295~302 (1995)
  10. "Loads anddesigns of screw joints for single crownssupported by osseointegrated implants", 7, pp.353~9 (1992)
  11. "Implant screw mechanics", 42(1), pp.71~89 (1998)
  12. "Tightening characteristicsfor screwed joints in osseointegrateddental implants", 71(6), pp.592~9
  13. "An introduction to the designand behavior of bolted joints", pp.247~64 (1981)
  14. "Examination of the implant-abutment interface after fatiguetesting", 85(3), pp.268~75 (2001)
  15. "Measuring abutment", implant joint integritywith the Periotest instrument, 1999Sep-Oct, pp.14(5), 681~8
  16. "Elongation and preload stress in dental implantabutment screws", 10, pp.529~36 (1995)
  17. "Micromotion and dynamic fatigue propertiesof the dental implant-abutment interface", 85(1), pp.47~52 (2001)
  18. "Microleakage at the abutment-implantinterface of osseointegrated implants: acomparative study", 14(1), pp.94~100 (1999)
  19. "The role ofscrews in implant systems", 9, pp.48~63 (1994)
  20. "The new restorative concept of the ITI dentalimplant system:design and engineering", 13, pp.409~31 (1993)
  21. "The evolution and evaluation oftwo interference-fit implant interfaces", 3(1), pp.17~21 (1996)
  22. "Effect of an antiro-tation resistanceform on screw loosening for singleimplant-supported crowns", 83, pp.450~5 (2000)
  23. "The effect ofthe use of a counter torque device on theabutment-implant complex", 81(4), pp.411~7 (1999)
  24. "Implant abutment screw rotations andpreloads for four different screw materialsand surfaces", 86(1), pp.24~32 (2001)
  25. "Effect of washers on reverse torquedisplacement of dental implant gold retainingscrews", 82(3), pp.312~6 (1999)
  26. "Implants and components: enteringthe new millennium", 15(1), pp.76~94 (2000)
  27. "An in vitro evaluation of thestrength of an internal conical interfacecompared to a butt joint interface in implantdesign", 8(4), pp.290~8 (1997)
  28. "Mechanics of the implant-abutment connection:an 8-degree taper compared toa butt joint connection", 15(4), pp.519~26 (2000)
  29. "Comparison of strength and failure modeof seven implant systems: an in vitrotest", 78(6), pp.582~91 (1997)
  30. "Masticatory funtion-a review of the literature", pp.57~62
  31. "In vivo vertical forces on implants", 10(1), pp.99~108 (1995)

관련 논문AI추천