임플랜트 지대주의 삭제과정이 결합부 안정성에 미치는 영향
THE EFFECT OF PREPARATION PROCEDURE ON IMPLANTABUTMENT JOINT STABILITY
1
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
Statement of problem: Little is known about the effect of abutment preparation procedure on de-torque values in different implant platform and the relationship of final de-torque values with different implant platform size. Purpose: This study evaluated the effect of abutment preparation procedure on de-torque values in different implant platform and the relationship of final de-torque values with different implant platform size. Material and method: Six ITI implants (2 narrow-neck implants, 2 regular-neck implants, 2 wide-neck implants) and six Branemark implants (2 narrow platforms, 2 regular platforms, 2 wide platforms) were embedded in each acrylic resin block with epoxy resin. Eighteen synOcta abutments (6 narrow-neck implant-abutments, 6 regular-neck implant-abutments, 6 wide-neck implant-abutments) and eighteen esthetic abutments (6 narrow platform-abutments, 6 regular platform-abutments, 6 wide platform-abutments) were tightened to each implant with digital torque gauge. Initial de-torque values were measured using digital torque gauge. After preparation of abutments, Final de-torque values were measured with digital torque gauge. Results and conclusion: 1. Screws loosening or abutments motion were not detected in all experimental group, but some scratches of implant-abutment joints were detected in all group. 2. Reduction ratios of final de-torque values were greater than initial de-torque values in all measured group, except in narrow-neck implant-abutment group (p<0.05). 3. Reduction ratios of final de-torque values in wide-neck implant-abutment group were greater than regular-neck implant-abutment group (p<0.01). 4. The greatest standard deviation value was detected in wide platform group in both implant systems.
참고문헌 (22)
- "Osseointegration and its ex-perimental background", pp.399~410 (1983), Branemark PI
- "The longitudinal clini-cal effectiveness of osseointegrated dental im-plants", 64 (1990)
- "Osseointegrated im-plants for single tooth replacement a 1-yearreport from a multicenter prospective study", pp.29~36 (1991)
- "The effect of implant", abutmenthexagonal misfit on screw joint stability, 1996, pp.bi(n pp), 149~60
- "Loads and de-signs of screw joints for single crowns supportedby osseointegrated implants", pp.353~9 (1992)
- "The preparation procedure of TiAdaptabutment effect on the implant to abut-ment joint stability", 33, pp.247~9 (2002)
- "Implant abutment screw rotations andpreloads for four different screw materials andsurfaces", 86, pp.24~32 (2001)
- "New tighteningtechnique for threaded fasteners Materialsand Engineering Proceedings of the Interna-tional Offshore Mechanics and Artic Enginee-ring Symposium AmericanSociety of Mechanical Engineers 1992;371-76", 3 (1992)
- "The effect of repeated torqueand salivary contamination on the preload ofslotted gold implant-prosthetic screws", 88, pp.183~91 (2002)
- "Elongation and preload stress in dentalimplant abutment screws", 10, pp.529~36 (1995)
- "Comparison of screw re-tention of nine abutment systems", 6, pp.28~31 (1997)
- "Fatigue resistance of two implant", abut-ment joint designs, 2002, pp.88, 604~10
- "Assessment of cold weldingproperties of the internal conical interface oftwo commercially available implant sys-tems", 81, pp.159~66 (1999)
- "Preload loss ingold prosthesis-retaining screws as a functionof time", 19, pp.124~32 (2004)
- "Theeffect of repeated torque on the ultimatetensile strength of slotted gold prostheticscrews", 88, pp.176~82 (2002)
- "The energy requirements of thedental cutting process", 7, pp.51~63 (1980)
- "Effects of bur abrasive particle size andabutment composition on preparation of ce-ramic implant abutments", 90, pp.247~54 (2003)
- "Waveanalysis of implant screw loosening using anair cylindrical cyclic loading device", 88, pp.402~8 (2002)
- "Dynamic fa-tigue properties of the dental implant-abut-ment interface joint opening in wide-diameterversus standard-diameter hex-type implants", 85, pp.599~607 (2001)
- "an 8-de-gree taper compared to a butt joint con-nection", 15, pp.519~26 (2000)
- "Microbialleakage and marginal fit of the implant-abutment interface", 12(4), pp.527~40 (1997)
- "Microbialleakage and marginal fit of the implant-abutment interface", 12(4), pp.527~40 (1997)