Abstract
Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: ⑴ to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, ⑵ to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, ⑶ to compare the detorque values of regular and wide diameter implants and ⑷ to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32N㎝ with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann- Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-Ⅱ regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-Ⅱ regular and wide implants showed higher detorque values than before(p<0.05).
참고문헌 (52)
- "A 15-yearstudy of osseointegrated implants in the treat-ment of the edentulous jaw", 10, pp.387~416 (1981)
- "The longitudinal clinical effica-cy of osseointegrated dental implants:A 3-year re-port", 2, pp.91~100 (1987)
- "A long-term follow-up of osseointegrated im-plants in the treatment of totally edentulous jaws", 5, pp.347~59 (1990)
- "The longitudinal clinical ef-fectiveness of osseointegrated implants", 64 (1990)
- "The effect of implant", abutment hexag-onal misfit on screw joint stability, 1996, pp.9, 149~60
- "Failures and complications in 391 con-secutively inserted fixed prostheses supportedby Branemark implants in edentulous jaws:Astudy of treatment from the time of prosthesisplacement to the first annual checkup", 6, pp.270~6 (1991)
- "Multicenter study of overdentures supportedby Branemark", 7, pp.513~22 (1992)
- "Failures and com-plications in 127 consecutively inserted fixed pros-theses supported by Branemark implants:Fromprostheses treatment to first annual check up", 7, pp.40~3 (1992)
- "Implantscrew mechanics", 42, pp.71~89 (1998)
- "Elongationand preload stress in dental implant abutmentscrews", 10, pp.529~36 (1995)
- "The effect of the useof a countertorque device on the abutment-implantcomplex", 81, pp.411~7 (1999)
- "A screw lock for single-tooth implant superstructures", 130, pp.677~82 (1999)
- "Mechanical complications of dentalimplants", pp.11 156~1 8 (2000)
- "Preventing loosening of implantabutment screws", 75, pp.566~9 (1996)
- "Loads and designsof screw joints for single crowns supported by os-seointegrated implants", 7, pp.353~9 (1992)
- "Wide diameter implants:indications,considerationsand preliminary results over a two-year period", 8, pp.31~7 (1994)
- "An in vitroevaluation of the strengthof an internal conical interface compared to abutt joint design", 8, pp.290~8 (1997)
- "Implants and components", 15, pp.633~45 (2000)
- "Mechanics of theimplant-abutment connection:an 8-degree tapercompared to a butt joint connection", 15, pp.519~26 (2000)
- "Evaluation of machining accuracy andconsistency of selected implants,standard abut-ments,and laboratory analogs", 8, pp.162~78 (1995)
- "The search for intimacy:Rotational ac-curacy of implant components for single-tooth,root-form implants", 2, pp.5~7 (1991)
- "Research status of prostho-dontic procedures", 6, pp.137~44 (1993)
- "Modified single and short span restorationssupported by osseointegrated fixtures in the par-tially edentulous jaw", 55, pp.243~7 (1986)
- "Loose gold screws frequent-ly occur in full arch fixed prostheses supported byosseointegrated implants after 5 years", 9, pp.169~78 (1994)
- "Osseointegrated implantsfor single tooth replacement:A 1-year report froma multicenter prospective study", 6, pp.29~36 (1991)
- "Replacement of maxillary andmandibular molars with single endosseous implantrestorations:A retrospective study", 74, pp.51~5 (1995)
- "Retrospective review of1170 endosseous implants placed in partiallyedentulous jaws", 79, pp.415~21 (1998)
- "The implant abutment connection:Thekey to prosthetic success", 12, pp.932~7 (1991)
- "OralImplantology" (1998), Thieme
- "The first 15 years of the Tu¨ebingen implant and itsfurther development to the Frialit-2 system", 8, pp.3~22 (1992)
- "Histometric andultrastructural studies of tissues surroundingAstra dental implants in dogs", 5, pp.127~34 (1990)
- "The Spline implant:Design,engineer-ing,and evaluation", 9, pp.419~33 (1996)
- "Dynamic fatigue proper-ties of the dental implant-abutment interface:Joint opening in wide- diameter versus standard-diameter hex-type implants", 85, pp.599~607 (2001)
- "Comparison of strength and failure mode of sev-en implant system:An in vitrotest", 78, pp.582~91 (1997)
- "Dental implants-Dynamic con-tinuous fatigue test" (2001)
- "The effect of eliminating im-plant", abutment rotational misfit on screw joint sta-bility, 1996, pp.9, 511~9
- "Stress fa-tigue:basic principles and prosthodontic impli-cations", 8, pp.105~16 (1995)
- "Cemented versus screw-retained implantprostheses: Which is better?", pp.138~9
- "The biomechanics of force distri-bution in implant-supported prostheses", 8, pp.19~31 (1993)
- "A comparison of im-plant-prosthesis loading with four clinical variables", 8, pp.421~33 (1995)
- "Implants and components:Enteringthe new millenium", 15, pp.76~94 (2000)
- "The newrestorative concept of the ITI dental implant sys-tem:design and engineering", 13, pp.409~31 (1993)
- "Assessment of cold welding proper-ties of the internal conical interface of two com-mercially available implant systems", 81, pp.159~66 (1999)
- "Mechanics of theimplant-abutment connection:an 8-degree tapercompared to a butt joint connection", 15, pp.519~26 (2000)
- "Nonlinear contactanalysis of preload in dental implant screws", 10, pp.295~302 (1995)
- "Tightening characteristics for screwed joints inosseointegrated dental implants", 71, pp.592~9 (1994)
- "A 3-year clinical study of Astradental implants in the treatment of edentulousmandibles", 7, pp.321~9 (1992)
- "Five year prospective follow-upreport of the Astra Tech Dental Implant System inthe treatment of edentulous mandibles", 9, pp.225~34 (1998)
- "A 5-year prospective clin-ical study of Astra Tech dental implants sup-porting fixed bridges or overdentures in the eden-tulous mandible", 8, pp.469~75 (1997)
- "Marginal bone levels at single tooth im-plants with a conical fixture design", 9, pp.91~9 (1998)
- "Aprospective study of Astra single tooth implants", 8, pp.173~9 (1997)
- "Biomechanical advantages of wide diameterimplants", 18, pp.687~94 (1997)