본문 바로가기
KERD
논문KCI 등재

중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구

Comparison of Size between direct-measurement and 3D body scanning

0

조회

0

다운로드

5

인용

0

참고문헌

키워드

주제분류생활과학

초록

This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below:In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of direct- measurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

Abstract

This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below:In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of direct- measurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

참고문헌 (14)

  1. Certain, A., "Automatic Body Measurement for Mass Customization of Garments", IEEE, pp.405~412 (1999)
  2. Mckinnon, L., "Body scanning", Journal of Fashion Marketing and Management, 6(2), pp.103~121 (2002)
  3. 한현숙, "3차원 스캔측정치와 직접치수간 차이의 성별 비교-제5차 Size Korea 성인데이터를 대상으로-", 한국의류학회지, 33(8), pp.1190~1202 (2009), 한국의류학회
  4. 백경자, "3차원 바디 스캐너를 이용한 남성 상반신 인체측정-직접측정과의 비교-", 한국의류학회지, 32(1), pp.24~34 (2008), 한국의류학회
  5. M. A. Brunsman, "Optimal Postures and positioning for Human body Scanning", Proceeding of International Conference on Recent Advanced in 3-D Digital Maping and Modeling (1997), Computer Society Press
  6. 백경자, "3차원 바디 스캐너를 이용한 남성 상반신 인체측정-직접측정과의 비교-", 한국의류학회지, 32(1), pp.24~34 (2008), 한국의류학회
  7. 한현숙, "3차원 스캔측정치와 직접치수간 차이의 성별 비교-제5차 Size Korea 성인데이터를 대상으로-", 한국의류학회지, 33(8), pp.1190~1202 (2009), 한국의류학회
  8. Mckinnon, L., "Comparative analysis of the image twin system and the 3T6 body scanner", Journal of Textile and Apparel Technology and Management, 1(2), pp.1~7 (2001)
  9. Robinette, K.M, "Precision of the CAESAR scan-extracted measurements", Applied Ergonomics, 37(3), pp.259~265 (2006)
  10. 차수정, "중국 성인여성용 브래지어 원형 개발 연구 : 상해지역 20대 전반 여성을 중심으로", 박사, pp.2008
  11. 산업자원부 기술표준원, "인체측정표준용어집" (2003)
  12. 이정임, "노년 여성 체형의 표준화된 3차원 측정 데이터 추출을 위한 기초 연구", 한국의류학회지, 28(2), pp.344~353 (2004), 한국의류학회

관련 논문AI추천

이 간행물의 다른 논문 (11건)