본문 바로가기
KERD
논문KCI 등재

내화학성 처리 후 Poly Phenylene Sulfide 정밀 여과 평막의 재질 및 투과율 변화 특성

Characteristics of Quality and Permeation Change of Poly Phenylene Sulfide Microfiltration Flat-sheet Membrane after Anti-chemial Pretreatment

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

This study was carried out to investigate the characteristics of permeation flow change after anti-chemical pre-treatment of microfiltration flat-sheet membrane that made of chlorinated PPS. This research used 0.5 wt. % NaClO for chloric condition, 1.0 wt. % HCl and pH 4 buffer solution for acidic condition, 4.0 wt. % NaOH and pH 10 buffer solution for alkaline condition, and the change of durability is investigated 1, 3, 5, and 10day after. As a result, the permeation flow in the chemical resistance solutions was increased or decreased according to the anti-chemical characteristics. Especially, the permeation flow between PPS membrane materials was increased or decreased even on the same conditions. From the result, it is noticed that the permeation flow characteristics are more influenced by membrane material and chemical than the chemical resistance solution used. In addition, further study is required to establish the optimal condition for the membrane material.

Abstract

This study was carried out to investigate the characteristics of permeation flow change after anti-chemical pre-treatment of microfiltration flat-sheet membrane that made of chlorinated PPS. This research used 0.5 wt. % NaClO for chloric condition, 1.0 wt. % HCl and pH 4 buffer solution for acidic condition, 4.0 wt. % NaOH and pH 10 buffer solution for alkaline condition, and the change of durability is investigated 1, 3, 5, and 10day after. As a result, the permeation flow in the chemical resistance solutions was increased or decreased according to the anti-chemical characteristics. Especially, the permeation flow between PPS membrane materials was increased or decreased even on the same conditions. From the result, it is noticed that the permeation flow characteristics are more influenced by membrane material and chemical than the chemical resistance solution used. In addition, further study is required to establish the optimal condition for the membrane material.

참고문헌 (11)

  1. K. Y. Chung, , J. Chemical Eng. Japan, 31(5), pp.683~ (1998)
  2. 남상용, "염료의 탈염", 정제, 멤브레인, pp.2006, 16(3)[DOI]
  3. 정건용, "회전원판을 이용한 침지형 분리막 모듈의 투과특성", 멤브레인, 16(1), pp.51~58 (2006), 한국막학회
  4. 남석태, "벤토나이트 현탁액에 의한 정밀여과 막의 오염특성", 멤브레인, 18(1), pp.53~64 (2008), 한국막학회
  5. 박진용, "관형 알루미나 세라믹 한외여과막에 의한 고도정수처리 시스템에서 물 역세척의 영향", 멤브레인, 19(3), pp.194~202 (2009), 한국막학회
  6. T. S. Hwang, , Polymer Journal, pp.621~628 (2000)
  7. A. G. Fane, , Desalination, 1, pp.106~ (1996)
  8. T. Ueda, , Water Res, 31, pp.489~ (1997)
  9. 유재상, "침지시간에 따른 Chlorinated Polyvinyl Chloride 정밀여과용 평막의 내화학적 특성", 멤브레인, 19(4), pp.324~332 (2009), 한국막학회
  10. "Korea Standards Association KSM ISO 3696", ~ (2005)
  11. B. G. Lee, , Journal of Fluid Machinery, pp.267~272 (2005)

관련 논문AI추천