본문 바로가기
KERD
논문KCI 등재

중금속 흡광도 측정에서 탁도 보정 기법의 적용

Application of Two-wavelength Absorbance Photometryin Turbid Water Samples

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

As turbidity can cause errors in measurements when absorbance photometry is used to determine the concentrations of heavy metal ions in real water samples (such as discharged water and industrially process water), fine solid particles should be removed during the sampling and/or sample preparation. However, complete removal is not always possible, and when an absorbance measurement needs to be carried out on a sample that is still turbid, a proper compensation method should be applied. In this short communication, accuracy was improved by means of a simple two-wavelength photometric method when absorbance was used to determine the concentrations of metal ions in samples of turbid water. The absorbance error decreased from 62.4~488% to 5.13~20.3% after the compensation method was applied.

Abstract

As turbidity can cause errors in measurements when absorbance photometry is used to determine the concentrations of heavy metal ions in real water samples (such as discharged water and industrially process water), fine solid particles should be removed during the sampling and/or sample preparation. However, complete removal is not always possible, and when an absorbance measurement needs to be carried out on a sample that is still turbid, a proper compensation method should be applied. In this short communication, accuracy was improved by means of a simple two-wavelength photometric method when absorbance was used to determine the concentrations of metal ions in samples of turbid water. The absorbance error decreased from 62.4~488% to 5.13~20.3% after the compensation method was applied.

참고문헌 (11)

  1. Z. Li, "A review of soil heavy metal pollution from mines in ChinaL Pollution and health risk assessment", Science of The Total Environment, 468-469, pp.843~853 (2014)
  2. M. Li, "Periodic-Table-Style"Paper Device for Monitoring Heavy Metals in Water", Analytical Chemistry, 87, pp.2555~2559 (2015)
  3. G. L. Xie, "A colorimetric microfluidic sensor made by a simple instrumental-free prototyping process for sensitive quantitation of copper", Chemical Papers, 73, pp.1509~1517 (2019)
  4. P. Richter, "Flow Injection Photometric Determination of Zinc and Copper With Zincon Based on the Variation of the Stability of the Complexes With pH", Analyst, 122, pp.1045~1048 (1997)
  5. P. Rumori, "Reversed flow injection and sandwich sequential injection methods for the spectrophotometric determination of copper(II) with cuprizone", Analytica Chimica Acta, 486, pp.227~235 (2003)
  6. M. T. Islam, "A Simple Spectrophotometric Method for the Trace Determination of Zinc in Some Real, Environmental, Biological, Pharmaceutical, Milk and Soil Samples Using 5, 7-Dibromo-8-hydroxyquinoline", Pak. J. Anal. Environ. Chem, 14, pp.1~15 (2013)
  7. G. J. Telesnicki, "Effects of Turbidiy on the Photosynthesis and Respiration of Two South Florida Reef Coral Species", Bulletin of Marine Science, 57, pp.527~539 (2014)
  8. 환경부, "수질관리 선진·과학화를 위한 수질TMS 설치·운영 업무편람", 54~ (2012)
  9. H. M. Lofty, "Novel two wavelength spectrophotometric method for simultaneous determination of binary mixtures severely overlapping spectra", Spectrochimica Acta Part A : Molecular and Biomolecular Spectroscopy, 136, pp.1786~1796 (2015)
  10. P. K. Dasgupta, "Light emitting diode-based detectors Absorbance, fluorescence and spectroelectrochemical measurements in a planar flow-through cell", Analytica Chimica Acta, 500, pp.337~364 (2003)
  11. 홍태기, "환경물 시료의 휴대용 탁도 측정 장치 개발", 환경분석과 독성보건, 13(1), pp.54~57 (2010), 한국환경분석학회

관련 논문AI추천

이 간행물의 다른 논문 (6건)