마이크로플레이트를 이용한 8종 화학물질의 복귀돌연변이 평가
Reverse Mutation Evaluation for Eight Chemicals using Microplate Method
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study was conducted to establish the technology for bacterial reverse mutation test using 384-well microplates and liquid media instead of solid agar in order to evaluate the mutagenicity of test articles with limited amounts. The important advantage of this test method was considered that the usage of S9 fraction prepared from rat liver was smaller in comparison with the Ames test using solid agar. Five bacterial strains (S. typhimurium TA98, TA100, TA1535, TA1537 and E. coli WP2 uvrA) recommended in OECD TG 471 were used to evaluate 8 chemicals including 6 mutagens (Allyl chloride, 4-amino-2-nitrophenol, ethylene glycol dimethyl ether, benzo[α]pyrene, 7,12-dimethylbenzanthracene, 8-hydroxyquinoline) and 2 non-mutagens (dioctyl phthalate, sulfisoxazole). All experiments were performed using Ames MPFTM Penta II kits (Xenometrix, Switzerland). Three independent laboratories participated in the intra-laboratory and inter-laboratory studies. Results from this study were compared with reference mutagenicity data (NTP or published data). In results of this study, five out of six mutagens were evaluated to be positive, and the one mutagen (ethylene glycol dimethyl ether) to be negative. Two non-mutagens were determined to be negative in microplate tests. Both the intra-laboratory and the inter-laboratory study showed the 87.5% concordance in the overall results. It was concluded that a microplated reverse mutation test may be a compatible test method for the animal welfare as well as for the limited amount of substances.
Abstract
This study was conducted to establish the technology for bacterial reverse mutation test using 384-well microplates and liquid media instead of solid agar in order to evaluate the mutagenicity of test articles with limited amounts. The important advantage of this test method was considered that the usage of S9 fraction prepared from rat liver was smaller in comparison with the Ames test using solid agar. Five bacterial strains (S. typhimurium TA98, TA100, TA1535, TA1537 and E. coli WP2 uvrA) recommended in OECD TG 471 were used to evaluate 8 chemicals including 6 mutagens (Allyl chloride, 4-amino-2-nitrophenol, ethylene glycol dimethyl ether, benzo[α]pyrene, 7,12-dimethylbenzanthracene, 8-hydroxyquinoline) and 2 non-mutagens (dioctyl phthalate, sulfisoxazole). All experiments were performed using Ames MPFTM Penta II kits (Xenometrix, Switzerland). Three independent laboratories participated in the intra-laboratory and inter-laboratory studies. Results from this study were compared with reference mutagenicity data (NTP or published data). In results of this study, five out of six mutagens were evaluated to be positive, and the one mutagen (ethylene glycol dimethyl ether) to be negative. Two non-mutagens were determined to be negative in microplate tests. Both the intra-laboratory and the inter-laboratory study showed the 87.5% concordance in the overall results. It was concluded that a microplated reverse mutation test may be a compatible test method for the animal welfare as well as for the limited amount of substances.
참고문헌 (31)
- Ames BN, "Carcinogens are mutagens : A simple test system combining liver homogenates for activation and bacteria for detection", Proc Nat Acad Sci USA, 70, pp.2281~2285 (1973)
- Escoba r PA, "Bacterial mutagenicity screening in the pharmaceutical industry", Mutat Res, 752, pp.99~118 (2013)
- The toxicology of glycol ethers and its relevance to man. Volume I, "European Centre for Ecotoxicology", ~, pp.Technical report No. 95 (2005)
- Flamand N, "Mini mutagenicity test : a minaturized version of Ames test used in a prescreening assay for point mutagenesis assessment", Toxicol in vitro, 15, pp.105~114 (2001)
- Fluckiger-Isler S, "Asessment of the performance of the Ames IITM a ssa y : a colla bora tive study with 19 coded compounds", Mutat Res, 558, pp.181~197 (2004)
- Fluckiger-Isler S, "Direct comparison of the Ames microplate format(MPF)test in liquid medium with the standard Ames pre-incubation assay on agar plates by use of equivocal to weakly positive test compounds", Mutat Res, 747, pp.36~45 (2012)
- Gee P, "Comparison of responses of base-specific Salmonella tester strains with the traditional strains for identifying mutagens : the results of a validation study", Mutat Res, 412, pp.115~130 (1998)
- IARC, "IARC Monographs on the Evaluation of Carcinogenic Risks to Humans. Certain Polycyclic Aromatic Hydrocarbons and Heterocyclic Compounds vol. 3", International Agency for Research on Cancer, ~ (1973)
- ICH, "Guideline S2B on genotoxicity: A standard battery for genotoxicity testing of pharmaceuticals", International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (1997)
- ICH., "Guideline M7 on assessment and control of DNA reactive(mutagenic)impurities in pharmaceuticals to limit potential carcinogenic risk", International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use. (2014)
- ISO., "No. 11350: Water quality-Determination of the genotoxicity of water and wastewater using the Salmonella", microsome fluctuation test (Ames fluctuation test), 2012
- Kamber M, "Comparison of the Ames II and traditional Ames test responses with respect to mutagenicity, strain specificities, need for metabolism and correlation with rodent carcinogenicity", Mutagenesis, 24, pp.359~366 (2009)
- Kirkla nd D, "Updated recommended lists of genotoxic and non-genotoxic chemicals for assessment of the performance of new or improved genotoxicity tests", Mutat Res Genet Toxicol Environ Mutagen, 795, pp.7~30 (2016)
- Lambert IB, "Detailed review of transgenic rodent mutation assays", Mutat Res, 590, pp.1~280 (2005)
- Dan D. Levy, "Recommended criteria for the evaluation of bacterial mutagenicity data (Ames test)", Mutation Research, 2019, pp.848, 403074~[DOI]
- Maron DM, "Revised methods for the Salmonella mutagenicity test", Mutat Res, 113, pp.173~215 (1983)
- McCann J, "Detection of carcinogens as mutagens : bacterial tester strains with R factor plasmids", Proc Nat Acad Sci USA, 72, pp.979~983 (1975)
- McCann J, "Detection of carcinogens as mutagens in the Salmonella", microsome test : Assay of 300 chemicals, 1975, pp.72, 5135~5139
- McGregor DB, "Genotoxicity of glycol ethers", Environ Health Perspect, 57, pp.97~103 (1984)
- Mortelmans K, "The Ames Salmonella", microsome mutagenicity assay, 2000, pp.455, 29~60
- "Chemical effects in biological systems" (2019)[URL]
- "Data Collections Guided Search" (2019)[URL]
- "Data Collections Guided Search" (2019)[URL]
- "Data Collections Guided Search. Mammalian cell cytogenetics" (2019)[URL]
- "Data Collections Guided Search" (2019)[URL]
- Nesnow S, "Chemical carcinogens. A review a nd a na lysis of the litera ture of selected chemica ls a nd the establishment ofthe Gene-Tox Carcinogen Data Base. A report of the U.S. Environmental Protection Agency Gene-Tox Program", Mutat Res, 185, pp.1~195 (1986)
- Nicolette J, "A comparison of 24 chemicals in the six-well bacterial reverse mutation assay to the standard 100-mm petri plate bacterial reverse mutation assay in two laboratories", Regul Toxicol Pharmacol, 100, pp.134~160 (2018)
- OECD., "Test No. 471 : Bacterial reverse mutation test, OECD guidelines for the Testing of chemicals" (2020), OECD Publishing
- Reifferscheid G, "International round-robin study on the Ames fluctuation test", Environ Mol Mutagen, 53, pp.185~197 (2012)
- Dimitrios Spiliotopoulos, "Assessment of the miniaturized liquid Ames microplate format (MPF™) for a selection of the test items from the recommended list of genotoxic and non-genotoxic chemicals", Mutation Research, 2020, pp.856-857, 503218~[DOI]
- Zwarg JRRM, "Miniaturization of the microsuspension Salmonella", Microsome assay in agar microplates, 2018, pp.59, 488~501
