Implant-Fixed Prostheses Restoration with New Retention Type Using Spread Fit Ti-Base System: A Case Report
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Spread Fit (SFIT) Ti-Base System was developed to overcome complications of conventional implant prosthesis system. This system uses a specific locking mechanism between the abutment and prosthesis instead of cement or screws, providing easy retrievability and no possibility of biological complications. This case report introduces clinical experience with a 3 - month follow-up of implant fixed prosthesis fabricated with SFIT Ti - Base System on a right maxillary posterior edentulous site. No biological complications or loss of retention was observed during the observation time. SFIT Ti-Base System is expected to be used in various clinical cases in the future
Abstract
Spread Fit (SFIT) Ti-Base System was developed to overcome complications of conventional implant prosthesis system. This system uses a specific locking mechanism between the abutment and prosthesis instead of cement or screws, providing easy retrievability and no possibility of biological complications. This case report introduces clinical experience with a 3 - month follow-up of implant fixed prosthesis fabricated with SFIT Ti - Base System on a right maxillary posterior edentulous site. No biological complications or loss of retention was observed during the observation time. SFIT Ti-Base System is expected to be used in various clinical cases in the future
참고문헌 (13)
- Misch CE, "Screw-retained versus cement-retained implant supported prostheses", Pract Periodontics Aesthet Dent, 7, pp.15~18 (1995)
- Chee W, "Cemented versus screw-retained implant prostheses : which is better", Int J Oral Maxillofac Implants, 14, pp.137~141 (1999)
- Misch CE, "Contemporary implant dentistry", pp.642~691 (1999), Mosby Inc.
- Hebel KS, "Cement-retained versusscrew-retained implantrestorations : achieving optimal occlusion and esthetics in implant dentistry", J Prosthet Dent, 77, pp.28~35 (1997)
- Michalakis KX, "Cementretainedversusscrew-retainedimplantrestorations : a critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
- Heo YK, "A newly designed screw-and cement-retained prosthesis and its abutments", Int J Prosthodont, 28, pp.612~614 (2015)
- zChoi JW, "Load-bearing capacity and retention of newly developed microlocking implant prosthetic system : An in vitro pilot study", Materials(Basel), 11, pp.564~ (2018)
- Shah KC, "Clinical application of a shape memory implant abutment system", J Prosthet Dent, 117, pp.8~12 (2017)
- Denny C, "Digital workflow for predictable immediate loading in the mandible by using a shape memory dental implant abutmentsystem : Aclinical report", J Prosthet Dent, 123, pp.1~5 (2020)
- Korsch M, "Cement associated peri-implantitis : A retrospective clinical observational study of fixed implant-supported restorations using a methacrylate cement", Clin Oral Implants Res, 25, pp.797~802 (2014)
- Goodacre CJ, "Tooth preparations for complete crowns : an art form based on scientific principles", J Prosthet Dent, 85, pp.363~376 (2001)
- Lee JH, "Axial displacements in external and internal implant-abutment connection", Clin Oral Implants Res, 25, pp.e83~e89 (2014)
- Dailey B, "Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque", Int J Oral Maxillofac Implants, 24, pp.251~256 (2009)