Implant-supported Full Mouth Rehabilitation Using Customized Non-precious Metal Casting Abutments: A Case Report
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
When treating an edentulous patient, it is difficult to rehabilitate and maintain long-term functionality with an implant-supported fixed prosthesis. This is because resorption of the remaining alveolar bone may cause dissonance with the opposite arch. We present a case involving customized abutments made using a conventional casting system with cobalt-chromium (Co-Cr) alloy, used to compensate for the shortcomings of prefabricated abutments. The customized abutment, used in conjunction with a cement-retained prosthesis, has shown satisfying result in both function and aesthetics during an eight-year follow-up of this particular patient.
Abstract
When treating an edentulous patient, it is difficult to rehabilitate and maintain long-term functionality with an implant-supported fixed prosthesis. This is because resorption of the remaining alveolar bone may cause dissonance with the opposite arch. We present a case involving customized abutments made using a conventional casting system with cobalt-chromium (Co-Cr) alloy, used to compensate for the shortcomings of prefabricated abutments. The customized abutment, used in conjunction with a cement-retained prosthesis, has shown satisfying result in both function and aesthetics during an eight-year follow-up of this particular patient.
참고문헌 (13)
- Adell R, "A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 5, pp.347~359 (1990)
- Jemt T, "Osseointegrated implants in the treatment of partially edentulous patients : a preliminary study on 876 consecutively placed fixtures", Int J Oral Maxillofac Implants, 4, pp.211~217 (1989)
- Haas R, "Brånemark single tooth implants : a preliminary report of 76 implants", J Prosthet Dent, 73, pp.274~279 (1995)
- Lang LA, "Evaluation of the precision of fit between the Procera custom abutment and variousimplantsystems", IntJ Oral Maxillofac Implants, 18, pp.652~658 (2003)
- Sumi T, "Characteristics of implant CAD", CAM abutment connections of two different internal connection systems, 2012, pp.39, 391~398
- 이창재, "CAD", CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가, 2012, pp.50(2), 128~134[DOI]
- Lewis S, "The"UCLA"abutment", IntJ Oral Maxillofac Implants, 3, pp.37~58 (1988)
- Lewis S, "The restoration ofimproperly inclined osseointegrated implants", Int J Oral Maxillofac Implants, 4, pp.147~152 (1989)
- Carotenuto G, "Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations", Clin Oral Implants Res, 10, pp.131~138 (1999)
- Duncan LA, "Effects of thermal treatments on protein adsorption of Co-Cr-Mo ASTM-F75 alloys", J Master Sci Master Med, 22, pp.1455~1464 (2011)
- 이진선, "원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구", 대한치과보철학회지, 50(2), pp.92~98 (2012), 대한치과보철학회[DOI]
- Oh KT, "Electrochemical properties of suprastructures galvanically coupled to a titanium implant", J Biomed Mater Res B Appl Biomater, 70, pp.318~331 (2004)
- Cho YS, "Efficacy of Co-Cr-Mo UCLA Abutment for Internal Tapered Implant", pp.2014