CAD/CAM 티타늄 맞춤 지대주로 수복한 구치부 임플란트에서의 기계적 합병증에 대한 후향적 연구
Mechanical Complications of Posterior Implant Restorations using CAD/CAM Titanium Customized Abutments: A Retrospective Study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this retrospective study was to evaluate the incidence of mechanical complications of the posterior implant-supported fixed dental prosthesis (p-ISFDP) using computeraided design and computer-aided manufacturing (CAD/CAM) titanium customized abutments and to evaluate the influencing factors on complications. Material and Methods: The incidence and consequences of mechanical complications in p-ISFDPs over a mean follow up period of 54.43 ± 6.24 months were assessed based on electronic documentations f rom 138 patients with 266 implants. All p-ISFDP utilized CAD/CAM titanium customized abutments, and were fabricated with cement-retained prostheses with occlusal screw access holes. Statistical analyses were performed to identify the risk factors of mechanical complications. Results: During the observation period (3 - 5 years), implant survival rates were 100%. Major mechanical complications were 8 abutment fractures (3.01%), 8 screw loosenings (3.01%), 2 screw fractures (0.75%), 11 chipping or fractures of veneering materials (5.58%), 23 decementations of the superstructure (11.68%). The relationship between the incidence of mechanical complications and the possible factors were not statistically significant(p > .05). Conclusion: There is no significant difference between each mechanical complication and the risk factors. P-ISFDP fabricated with CAD/CAM titanium abutments is a clinically acceptable treatment.
Abstract
Purpose: The purpose of this retrospective study was to evaluate the incidence of mechanical complications of the posterior implant-supported fixed dental prosthesis (p-ISFDP) using computeraided design and computer-aided manufacturing (CAD/CAM) titanium customized abutments and to evaluate the influencing factors on complications. Material and Methods: The incidence and consequences of mechanical complications in p-ISFDPs over a mean follow up period of 54.43 ± 6.24 months were assessed based on electronic documentations f rom 138 patients with 266 implants. All p-ISFDP utilized CAD/CAM titanium customized abutments, and were fabricated with cement-retained prostheses with occlusal screw access holes. Statistical analyses were performed to identify the risk factors of mechanical complications. Results: During the observation period (3 - 5 years), implant survival rates were 100%. Major mechanical complications were 8 abutment fractures (3.01%), 8 screw loosenings (3.01%), 2 screw fractures (0.75%), 11 chipping or fractures of veneering materials (5.58%), 23 decementations of the superstructure (11.68%). The relationship between the incidence of mechanical complications and the possible factors were not statistically significant(p > .05). Conclusion: There is no significant difference between each mechanical complication and the risk factors. P-ISFDP fabricated with CAD/CAM titanium abutments is a clinically acceptable treatment.
참고문헌 (34)
- Romanos GE, "Concepts for prevention of complications in implant therapy", Periodontol 2000, 81, pp.7~17 (2019)
- Jung RE, "Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years", Clin Oral Implants Res, 23, pp.2~21 (2012)
- Pjetursson BE, "A systematic review of the survival and complication rates of implant-supported fixed dental prostheses (FDPs) after a mean observation period of at least 5years", Clin Oral Implants Res, 23, pp.22~38 (2012)
- Berglundh T, "A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years", J Clin Periodontol, 29, pp.197~212 (2002)
- Wittneben JG, "Complication and failure rates with implant supported fixed dental prostheses and single crowns:a 10-year retrospective study", Clin Implant Dent Relat Res, 16, pp.356~364 (2014)
- Sadid-Zadeh R, "Prosthetic failure in implant dentistry", Dent Clin North Am, 59, pp.195~214 (2015)
- Sailer I, "Cemented and screw-retained implant reconstructions- a systematic review of the survival and complication rates", Clin Oral Implants Res, 23, pp.163~201 (2012)
- Sailer I, "A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions", Clin Oral Implants Res, 20, pp.4~31 (2009)
- Zembic A, "Systematic review of the survival rate and incidence of biologic, technical and esthetic complications of single implant abutments supporting fixed prostheses", Int J Oral Maxillofac Implants, 29(Suppl), pp.99~116 (2014)
- ElHoussiney AG, "Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis", Clin Cosmet Investig Dent, 10, pp.19~35 (2018)
- Dhima M, "Practice-based evidence from 29-year outcome analysis of management of the edentulous jaw using osseointegrated dental implants", J Prosthodont, 23, pp.173~181 (2014)
- Pjetursson BE, "Improvements in implant dentistry over the last decade: comparison of survival and complication rates in older and newer publications", Int J Oral Maxillofac Implants, 29, pp.308~324 (2014)
- Kapos T, "CAD", CAM Technology for Implant Abutments, Crowns, and Superstructures, 2014, pp.29(Suppl), 117~136
- 윤기준, "Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant", The Journal of Advanced of Prosthodontics, 8(6), pp.465~471 (2016), 대한치과보철학회[DOI]
- 이유승, "Comparison of implant component fractures in external and internal type: A 12-year retrospective study", The Journal of Advanced of Prosthodontics, 10(2), pp.155~162 (2018), 대한치과보철학회[DOI]
- Vigolo P, "Evaluation of goldmachined UCLA-type abutments and CAD", CAM titanium abutments with hexagonal external connection and with internal connection, 2008, pp.23, 247~252
- Abduo J, "Fit of CAD", CAM implant frameworks: A comprehensive review, 2014, 758~766
- Lee JH, "Comparison of Customized Abutments Made from Titanium and a Machinable Precious Alloy", Int J Oral Maxillofac Implants, 31, pp.92~100 (2016)
- 김은숙, "Influence of the implant abutment types and the dynamic loading on initial screw loosening", The Journal of Advanced of Prosthodontics, 5(1), pp.21~28 (2013), 대한치과보철학회[DOI]
- 이창재, "CAD", CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가, 2012, pp.50(2), 128~134[DOI]
- Korsch M, "Prefabricated versus customized abutment: A retrospective analysis of loosening of cement-retained fixed implant-supported reconstructions", Int J Prosthodont, 28, pp.522~526 (2015)
- Covey DA, "Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns", J Prosthet Dent, 83, pp.344~348 (2000)
- Guncu MB, "Comparison of 3 luting agents on retention of implant-supported crowns on 2 different abutments", Implant Dent, 20, pp.349~353 (2011)
- Wadhwani C, "Effects of abutment and screw access channel modification on dislodgement of cement-retained implant-supported restorations", Int J Prosthodont, 26, pp.54~56 (2013)
- Albrektsson T, "Implant survival and complications. The Third EAO consensus conference", Clin Oral Implants Res, 23(Suppl. 6), pp.63~65 (2012)
- Priest G, "Virtual-designed and computer-milled implant abutments", J Oral Maxillofac Surg, 63(Suppl. 2), pp.22~32 (2005)
- Theodoros Kapos, "CAD", CAM Technology for implant abutments, crowns, and superstructures, 2014, pp.29, 117~136
- Zembic A, "Randomized-controlled clinical trial of customized zirconia and titanium implant abutments for single-tooth implants in canine and posterior regions:3-year results", Clin Oral Implants Res, 20, pp.802~808 (2009)
- Wang JHY, "A 5-Year Retrospective Assay of Implant Treatments and Complications in Private Practice:The Restorative Complications of Single and Shor-Span Implant-Supported Fixed Prosthesis", Int J Prosthodont, 29, pp.435~444 (2016)
- Balshi TJ, "An analysis and management of fractured implants: a clinical report", Int J Oral Maxillofac Implants, 11, pp.660~666 (1996)
- Sadowsky SJ, "Occlusal overload with dental implants: a review", Int J Implant Dent, 5, pp.29~ (2019)
- Balslhi TJ, "A comparative study of one implant versus two replacing a single molar", Int J Oral Maxillofac Implants, 11, pp.372~378 (1996)
- Pjetursson BE, "Comparison of survival and complication rates of toothsupported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)", Clin Oral Implants Res, 18, pp.97~113 (2007)
- Hu KW, "Compatible CAD-CAM titanium abutments for posterior single-implant tooth replacement: A retrospective case series", J Prosthet Dent, 117, pp.363~366 (2017)