Purpose: This study aimed to report dental implant removal due to various instances of implant abutment and screw fractures. In this study, the indications for implant removal due to mechanical failure were documented. Materials and Methods: This study investigated patients referred to the Department of Oral and Maxillofacial Surgery of our hospital for implant removal surgery due to abutment screw fractures between 2010 and 2024. The study included 13 patients with 15 implants. Patient age, sex, implant location, fracture site, and implant system type were investigated. Results: Fifteen implants were removed in 13 patients with abutment and screw fractures. The mean age of the patients was 63.4 years. Moreover, a total of 11 men and two women were included in the analysis. The implants were most commonly placed in the molar region, with a maxilla-to-mandible ratio of 9:6. The screw fracture locations were categorized into the cervical, middle, or apical thirds. Their corresponding numbers were two, eight, and four, respectively. The implant system and manufacturer demonstrated no significant correlation with screw fractures. Conclusion: When a screw fracture occurs in the lower third of a dental implant, removal is often difficult. Regular check-ups and periodic screw tightening are mandatory to prevent severe complications such as screw or abutment fractures. Failed implants should be removed and replaced with new dental implants.

Abstract

Purpose: This study aimed to report dental implant removal due to various instances of implant abutment and screw fractures. In this study, the indications for implant removal due to mechanical failure were documented. Materials and Methods: This study investigated patients referred to the Department of Oral and Maxillofacial Surgery of our hospital for implant removal surgery due to abutment screw fractures between 2010 and 2024. The study included 13 patients with 15 implants. Patient age, sex, implant location, fracture site, and implant system type were investigated. Results: Fifteen implants were removed in 13 patients with abutment and screw fractures. The mean age of the patients was 63.4 years. Moreover, a total of 11 men and two women were included in the analysis. The implants were most commonly placed in the molar region, with a maxilla-to-mandible ratio of 9:6. The screw fracture locations were categorized into the cervical, middle, or apical thirds. Their corresponding numbers were two, eight, and four, respectively. The implant system and manufacturer demonstrated no significant correlation with screw fractures. Conclusion: When a screw fracture occurs in the lower third of a dental implant, removal is often difficult. Regular check-ups and periodic screw tightening are mandatory to prevent severe complications such as screw or abutment fractures. Failed implants should be removed and replaced with new dental implants.

참고문헌 (26)

  1. Levine RA, "Multicenter retrospective analysis of the ITI implant system used for single-tooth replacements : results of loading for 2 or more years", Int J Oral Maxillofac Implants, 14, pp.516~520 (1999)
  2. Buser D, "Long-term evaluation of non-submerged ITI implants. Part 1 : 8-year life table analysis of a prospective multi-center study with 2359 implants", Clin Oral Implants Res, 8, pp.161~172 (1997)
  3. Adell R, "Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws", Int J Oral Maxillofac Implants, 5, pp.347~359 (1990)
  4. Grunder U, "A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants", Int J Oral Maxillofac Implants, 14, pp.210~216 (1999)
  5. Tonetti MS, "Pathogenesis of implant failures", Periodontol 2000, 4, pp.127~138 (1994)
  6. Kochar SP, "The Etiology and Management of Dental Implant Failure : A Review", Cureus, 14, pp.e30455~ (2022)
  7. Balshi TJ, "An analysis and management of fractured implants : a clinical report", Int J Oral Maxillofac Implants, 11, pp.660~666 (1996)
  8. Kurt M, "A technique for removal of a fractured implant abutment screw", J Oral Implantol, 39, pp.723~725 (2013)
  9. Behr M, "Complication rate with prosthodontic reconstructions on ITI and IMZ dental implants. Internationales Team fur Implantologie", Clin Oral Implants Res, 9, pp.51~58 (1998)
  10. Goodacre CJ, "Clinical complications of osseointegrated implants", J Prosthet Dent, 81, pp.537~552 (1999)
  11. Goodacre CJ, "Clinical complications with implants and implant prostheses", J Prosthet Dent, 90, pp.121~132 (2003)
  12. Nergiz I, "Removal of a fractured implant abutment screw : a clinical report", J Prosthet Dent, 91, pp.513~517 (2004)
  13. Carneiro Tde A, "A conservative approach to retrieve a fractured abutment screw-Case report", J Prosthodont Res, 60, pp.138~142 (2016)
  14. Quek CE, "Load fatigue performance of a single-tooth implant abutment system : effect of diameter", Int J Oral Maxillofac Implants, 21, pp.929~936 (2006)
  15. Chen JH, "An accessory technique for the intraoral removal of a fractured implant abutment screw", J Prosthet Dent, 120, pp.812~815 (2018)
  16. Gooty JR, "Noninvasive method for retrieval of broken dental implant abutment screw", Contemp Clin Dent, 5, pp.264~267 (2014)
  17. van den Broeke SM, "Fracture of implant abutment screws and removal of a remaining screw piece", Ned Tijdschr Tandheelkd, 115, pp.360~367 (2008)
  18. Oshida Y, "Dental implant systems", Int J Mol Sci, 11, pp.1580~1678 (2010)
  19. Skalak R, "Biomechanical considerations in osseointegrated prostheses", J Prosthet Dent, 49, pp.843~848 (1983)
  20. Schwarz MS, "Mechanical complications of dental implants", Clin Oral Implants Res, 11(Suppl 1), pp.156~158 (2000)
  21. Garner LD, "Correlation study of incisive biting forces with age, sex, and anterior occlusion", J Dent Res, 52, pp.698~702 (1973)
  22. Shinogaya T, "Bite force and occlusal load in healthy young subjects--a methodological study", Eur J Prosthodont Restor Dent, 8, pp.11~15 (2000)
  23. Katsavochristou A, "Incidence of abutment screw failure of single or splinted implant prostheses : A review and update on current clinical status", J Oral Rehabil, 46, pp.776~786 (2019)
  24. Cosyn J, "The effectiveness of immediate implant placement for single tooth replacement compared to delayed implant placement : A systematic review and meta-analysis", J Clin Periodontol, 46(Suppl 21), pp.224~241 (2019)
  25. Checchi V, "Wide diameter immediate post-extractive implants vs delayed placement of normal-diameter implants in preserved sockets in the molar region : 1-year post-loading outcome of a randomised controlled trial", Eur J Oral Implantol, 10, pp.263~278 (2017)
  26. Flanagan D, "Management of a Fractured Implant Abutment Screw", J Oral Implantol, 42, pp.508~511 (2016)

관련 논문AI추천

이 간행물의 다른 논문 (5건)