This case report discusses the approach and considerations involved in retrieving a fractured implant abutment screw. A 69-year-old male patient presented with a dislodged implant prosthesis caused by a fractured abutment screw. The fracture occurred at the most apical portion of the screw, specifically in the threaded region, making its retrieval particularly challenging. The screw was successfully removed using a commercially available retrieval kit. The effectiveness of the kit was attributed to a guide that allowed the retrieval instrument to align precisely with the long axis of the implant. Without such a guide, a risk of damaging the internal threads of the implant fixture exists, potentially leading to the need for implant removal. Therefore, using a retrieval kit with a guide or fabricating a custom-made guide is crucial for preventing implant damage and ensuring proper alignment during the procedure.

Abstract

This case report discusses the approach and considerations involved in retrieving a fractured implant abutment screw. A 69-year-old male patient presented with a dislodged implant prosthesis caused by a fractured abutment screw. The fracture occurred at the most apical portion of the screw, specifically in the threaded region, making its retrieval particularly challenging. The screw was successfully removed using a commercially available retrieval kit. The effectiveness of the kit was attributed to a guide that allowed the retrieval instrument to align precisely with the long axis of the implant. Without such a guide, a risk of damaging the internal threads of the implant fixture exists, potentially leading to the need for implant removal. Therefore, using a retrieval kit with a guide or fabricating a custom-made guide is crucial for preventing implant damage and ensuring proper alignment during the procedure.

참고문헌 (10)

  1. Wittneben JG, "Complication and failure rates with implant-supported fixed dental prostheses and single crowns : A 10-year retrospective study", Clin Implant Dent Relat Res, 16, pp.356~364 (2014)
  2. Nergiz I, "Removal of a fractured implant abutment screw : A clinical report", J Prosthet Dent, 91, pp.513~517 (2004)
  3. Zhang WT, "Retrieval of a fractured implant abutment using a modified cover screw removal instrument : A clinical report", J Prosthet Dent, 15, pp.S0022-3913(23)00543-7~ (2023)
  4. Jung RE, "A systematic review of the 5-year survival and complication rates of implant-supported single crowns", Clin Oral Implants Res, 19, pp.119~130 (2008)
  5. Goodacre CJ, "Clinical complications of osseointegrated implants", J Prosthet Dent, 81, pp.537~552 (1999)
  6. Mizumoto RM, "A risk-based decision making tree for managing fractured abutment and prosthetic screws : A systematic review", J Prosthet Dent, 119, pp.552~559 (2018)
  7. Chowdhary R, "Implant abutment screw fracture and techniques of retrieval : a literature review based on a novel abutment screw fracture classification", J Osseointegr, 15, pp.32~39 (2023)
  8. Taira Y, "A modified technique for removing a failed abutment screw from an implant with a custom guide tube", J Oral Implantol, 38, pp.165~169 (2012)
  9. Yoon JH, "Safe Removal of a Broken Abutment Screw with Customized Drill Guide and Rotary Instrument : A Clinical Report", J Prosthodont, 25, pp.170~173 (2016)
  10. Huang H, "Removal of broken screws on implant abutment by digital guide plate : A case report and literature review", J Appl Biomater Funct Mater, 21, pp.1~2 (2023)

관련 논문AI추천

이 간행물의 다른 논문 (4건)