Objectives The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS)equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast,if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was 28.3° when tongue was lightly exposed and 13.3° when maximally. So we determined 73° as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Abstract

Objectives The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS)equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast,if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was 28.3° when tongue was lightly exposed and 13.3° when maximally. So we determined 73° as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

참고문헌 (14)

  1. 이봉교, "한방진단학", pp.70~91 (1992), 성보사
  2. 김지은, "설 진단에서 주관적 판단의 신뢰성 평가", 대한의용생체공학회 학술대회 (2003)
  3. Kim M, "Traditional Chinese medicine tongue inspection: an examination of the inter- and intrapractitioner reliability for specific tongue characteristics", J Altern Complement Med, 14, pp.527~536 (2008)
  4. 김보연, "디지털 설진 획득 및 관리 시스템의 개발", 대한한의진단학회지, 6, pp.65~78 (2002)
  5. Pang B, "Computerized tongue diagnosis based on Bayesian networks", IEEE Trans Biomed Eng, 51, pp.1803~1810 (2004)
  6. Chiu CC, "A novel approach based on computerized image analysis for traditional Chinese medical diagnosis of the tongue", Comput Methods Programs Biomed, 6, pp.77~89 (2000)
  7. Pang B, "The bi-elliptical deformable contour and its application to automated tongue segmentation in Chinese medicine", IEEE Trans Med Imaging, 24, pp.946~956 (2005)
  8. 전영주, "설진 시스템 개발 및 재현성 평가", 한국한의학연구원논문집, 14(3), pp.97~102 (2008), 한국한의학연구원
  9. Yamamoto S, "Regional image analysis of the tongue color spectrum", Int J Comput Assist Radiol Surg, 6, pp.143~152 (2011)
  10. 전영주, "김종열. 설진시스템 개발 및 재현성 평가", 한국한의학회지, 14, pp.97~101 (2008)
  11. 어윤혜, "표리한열의 설 특성에 관한 정량적 연구", 대한한의학회지, 27(2), pp.134~144 (2006), 대한한의학회
  12. Sun L, "Study on objective tongue diagnosis using computerized image recognition technique", J. Anhui traditional chinese medical college, 5, pp.5~7 (1989)