외부광 차단을 위한 설진기 안면접촉부 설계
Structural Design of Facial Contact Parts in Computerized Tongue Diagnosis System to Block Out External Light
3
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
ObjectivesThe aim of this study is to design a part in contact with the face of computerized tongue diagnosis system(CTDS), so that external light is effectively shielded even if the facial appearance and degree of protrusion differwhen a patient opens or closes his/her jaws. MethodsEach of the 4 researchers manually produced clay models of the part in contact with the face of CTDS. Shieldingand contact feeling of the clay models were evaluated by 20 assessors. Based on the evaluation, we selectedthe appropriate model and produced the final silicon model. Then we evaluated the performance of the shieldingof the completed silicon model. We took tongue pictures of 60 participants with a CTDS applying the siliconmodel in condition with external light and without it. The color values in RGB color model and gray scaleof the tongue pictures in condition with external light were compared with those without external light. ResultsThere was no significant difference between the color values of the picture taken in condition with externallight and those without external light. ConclusionsWe concluded that the produced part in contact with the face of CTDS can effectively block out the externallight.
Abstract
ObjectivesThe aim of this study is to design a part in contact with the face of computerized tongue diagnosis system(CTDS), so that external light is effectively shielded even if the facial appearance and degree of protrusion differwhen a patient opens or closes his/her jaws. MethodsEach of the 4 researchers manually produced clay models of the part in contact with the face of CTDS. Shieldingand contact feeling of the clay models were evaluated by 20 assessors. Based on the evaluation, we selectedthe appropriate model and produced the final silicon model. Then we evaluated the performance of the shieldingof the completed silicon model. We took tongue pictures of 60 participants with a CTDS applying the siliconmodel in condition with external light and without it. The color values in RGB color model and gray scaleof the tongue pictures in condition with external light were compared with those without external light. ResultsThere was no significant difference between the color values of the picture taken in condition with externallight and those without external light. ConclusionsWe concluded that the produced part in contact with the face of CTDS can effectively block out the externallight.
참고문헌 (12)
- 이봉교, "한방진단학", pp.70~91 (1992), 성보사
- 주문봉, "중의진단학", pp.159~272 (1999), 인민위생출판사
- 백승희, "설진의 증례보고", 제한동의학술원 논문집, 4, pp.389~399 (1999)
- 박종기, "설진의 역사에 관한 연구(Ⅰ)", 대전대학교 한의학연구소 논문집, 5, pp.281~292 (1997)
- 김보연, "디지털 설진 시스템의개발에 관한 연구", 제25회 대한의용생체공학회추계학술대회 (2011)
- 전영주, "설진 시스템 개발 및 재현성 평가", 한국한의학연구원논문집, 14(3), pp.97~102 (2008), 한국한의학연구원
- Yamamoto S, "Regional image analysis of the tongue color spectrum", Int J Comput Assist Radiol Surg, 6, pp.143~152 (2011)
- 김보연, "디지털 설진 획득 및 관리 시스템의개발", 대한한의학진단학회지, 6, pp.65~78 (2002)
- 정용재, "디지털 설진기를 이용한 구취군과 비구취군 간의 설태 평가", 대한한의학회지, 31(1), pp.23~29 (2010), 대한한의학회
- 손지희, "설진의 표준화를 위한 제언 : 설태 후박의 진단기준을 중심으로", 대한한방내과학회지, 33(1), pp.1~13 (2012), 대한한방내과학회
- 남동현, "LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발", 대한한의진단학회지, 16(3), pp.41~48 (2012), 대한한의진단학회
- Kim J, "Availability of tongue diagnosis system for assessing tongue coating thickness in patients with functional dyspepsia", Evid Based Complement Alternat Med, pp.348272~ (2013)