Detailed Electrode Catheter Positioning is Important for the Ablation of Outflow Tract Origin Ventricular Arrhythmias
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and Objectives: Electroanatomical mapping using a three-dimensional (3D) system has high accuracy and improves the results of the ablation of outflow tract (OT) premature ventricular contraction (PVC) or ventricular tachycardia (VT) but imposes a considerable economic burden. Here, we compared detailed diagnostic catheterization and 3D mapping system for the ablation of OT PVC/VT. Materials and Methods: Between June 2012 and February 2017, patients with symptomatic OT PVC/VT underwent radiofrequency ablation. Group 1 underwent detailed diagnostic catheterization (using circular and linear multielectrodes) without a 3D mapping system, while group 2 underwent diagnostic catheterization using a conventional 3D mapping system. Procedural success of PVC reduction, remaining symptoms, need for post-operative medications, and procedural time were evaluated. Results: Ninety-eight OT PVC/VT cases were consecutively enrolled. The mean follow-up period was 17.7±14.5 months. Neither acute success rate (95% vs. 82%, p=0.06) nor a PVC reduction > 80% (84% vs. 87%, p=0.74) differed significantly between the two groups. The recurrence rates of PVC-related symptoms were similar (12% vs. 7%, p=0.06) between the groups, but the medication requirement for symptomatic PVC differed (12% vs. 29%, p<0.01). The total procedure time of group 1 was shorter than that of group 2 (132±42 min vs. 157±47 min, p=0.01) and fluoroscopy time (24±15 min vs. 38±22 min, p<0.01) and ablation time (528±538 sec vs. 899±598 sec, p<0.01) were also significantly shortened. Conclusion: Detailed electrode catheter positioning is a safe and cost-effective method for the ablation of OT PVC/VT.
Abstract
Background and Objectives: Electroanatomical mapping using a three-dimensional (3D) system has high accuracy and improves the results of the ablation of outflow tract (OT) premature ventricular contraction (PVC) or ventricular tachycardia (VT) but imposes a considerable economic burden. Here, we compared detailed diagnostic catheterization and 3D mapping system for the ablation of OT PVC/VT. Materials and Methods: Between June 2012 and February 2017, patients with symptomatic OT PVC/VT underwent radiofrequency ablation. Group 1 underwent detailed diagnostic catheterization (using circular and linear multielectrodes) without a 3D mapping system, while group 2 underwent diagnostic catheterization using a conventional 3D mapping system. Procedural success of PVC reduction, remaining symptoms, need for post-operative medications, and procedural time were evaluated. Results: Ninety-eight OT PVC/VT cases were consecutively enrolled. The mean follow-up period was 17.7±14.5 months. Neither acute success rate (95% vs. 82%, p=0.06) nor a PVC reduction > 80% (84% vs. 87%, p=0.74) differed significantly between the two groups. The recurrence rates of PVC-related symptoms were similar (12% vs. 7%, p=0.06) between the groups, but the medication requirement for symptomatic PVC differed (12% vs. 29%, p<0.01). The total procedure time of group 1 was shorter than that of group 2 (132±42 min vs. 157±47 min, p=0.01) and fluoroscopy time (24±15 min vs. 38±22 min, p<0.01) and ablation time (528±538 sec vs. 899±598 sec, p<0.01) were also significantly shortened. Conclusion: Detailed electrode catheter positioning is a safe and cost-effective method for the ablation of OT PVC/VT.
참고문헌 (17)
- Aliot EM, "EHRA", HRS expert consensus on catheter ablation of ventricular arrhythmias: developed in a partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA), 2009, pp.11, 771~817
- Grimm W, "Reversal of tachycardia induced cardiomyopathy following ablation of repetitive monomorphic right ventricular outflow tract tachycardia", Pacing Clin Electrophysiol, 24, pp.166~171 (2001)
- Mountantonakis SE, "Reversal of outflow tract ventricular premature depolarization-induced cardiomyopathy with ablation:effect of residual arrhythmia burden and preexisting cardiomyopathy on outcome", Heart Rhythm, 8, pp.1608~1614 (2011)
- Nakagawa M, "Gender differences in various types of idiopathic ventricular tachycardia", J Cardiovasc Electrophysiol, 13, pp.633~638 (2002)
- Friedman PA, "Noncontact mapping to guide ablation of right ventricular outflow tract tachycardia", J Am Coll Cardiol, 39, pp.1808~1812 (2002)
- Fung J, "Ablation of nonsustained or hemodynamically unstable ventricular arrhythmia originating from the right ventricular outflow tract guided by noncontact mapping", Pacing Clin Electrophysiology, 26, pp.1699~1705 (2003)
- Aiba T, "Clinical usefulness of a multielectrode basket catheter for idiopathic ventricular tachycardia originating from right ventricular outflow tract", J Cardiovasc Electrophysiol, 12, pp.511~517 (2001)
- Saleem MA, "New simplified technique for 3d mapping and ablation of right ventricular outflow tract tachycardia", Pacing Clin Electrophysiol, 28, pp.397~403 (2005)
- Baser K, "Predictors of outcome after catheter ablation of premature ventricular complexes", J Cardiovasc Electrophysiol, 25, pp.597~601 (2014)
- Baman TS, "Relationship between burden of premature ventricular complexes and left ventricular function", Heart Rhythm, 7, pp.865~869 (2010)
- Calkins. H, "Relation between efficacy of radiogfrequency catheter ablation and site of origin of idiopathic ventricular tachycardia", Am J Cardiol, 71, pp.827~833 (1993)
- Ribbing M, "Endocardial mapping of right ventricular outflow tract tachycardia using noncontact activation mapping", J Cardiovasc Electrophysiol, 14, pp.602~608 (2003)
- Erkapic D, "Ablation of premature ventricular complexes exclusively guided by three-dimensional noninvasive mapping", Card Electrophysiol Clin, 7, pp.109~115 (2015)
- Erkapic D, "Clinical impact of a novel threedimensional electrocardiographic imaging for non-invasive mapping of ventricular arrhythmias-a prospective randomized trial", Europace, 17, pp.591~597 (2015)
- Jamil-Copley S, "Noninvasive electrocardiographic mapping to guide ablation of outflow tract ventricular arrhythmias", Heart Rhythm, 11, pp.587~594 (2014)
- Kesek M, "Entrapment of circular mapping catheter in the mitral valve", Heart Rhythm, 4, pp.17~19 (2007)
- Coggins DL, "Radiofrequency catheter ablation as a cure for idiopathic tachycardia of both left and right ventricular origin", J Am Coll Cardiol, 23, pp.1333~1341 (1994)