Maximum flexion and lateral rollback revealed better patient satisfaction after total knee arthroplasty
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Introduction Patient satisfaction is an important outcome of total knee arthroplasty (TKA). However, we cannot predict how and why patients are satisfied or dissatisfied with TKA. The hypothesis of this study was that patient-reported outcomes (PROs) correlate with in vivo kinematics after TKA. Materials and methods One hundred knees were analyzed after TKA. The in vivo kinematics of deep knee bending motion were estimated from single-plane fluoroscopy using a two-to-three-dimensional registration technique. Active knee flexion, femoral rotation and rollback were evaluated. The PROs were obtained after surgery using the 2011 Knee Society Scoring System (KSS), and their relationship with in vivo kinematics was determined. Results The average minimum and maximum flexion were −2.4 ± 7.3° and 113.2 ± 13.6°, respectively. The average femoral rotation was 7.4 ± 3.4°, and the average medial and lateral rollback were 2.4 ± 4.8 mm and 7.2 ± 5.6 mm, respectively. The multiple regression analysis revealed that the maximum flexion angle significantly contributed to symptoms and satisfaction. In addition, lateral rollback was also a significant factor affecting patient satisfaction. Lateral rollback and lateral Anterior-Posterior (AP) position at maximum flexion were correlated with the maximum flexion angle, whereas femoral rotation did not correlate with flexion angles. Conclusions Maximum flexion and lateral rollback are important for better patient satisfaction after TKA. To obtain the maximum flexion angle, it was necessary to perform the normal kinematic pattern with a large amount of lateral rollback.
Abstract
Introduction Patient satisfaction is an important outcome of total knee arthroplasty (TKA). However, we cannot predict how and why patients are satisfied or dissatisfied with TKA. The hypothesis of this study was that patient-reported outcomes (PROs) correlate with in vivo kinematics after TKA. Materials and methods One hundred knees were analyzed after TKA. The in vivo kinematics of deep knee bending motion were estimated from single-plane fluoroscopy using a two-to-three-dimensional registration technique. Active knee flexion, femoral rotation and rollback were evaluated. The PROs were obtained after surgery using the 2011 Knee Society Scoring System (KSS), and their relationship with in vivo kinematics was determined. Results The average minimum and maximum flexion were −2.4 ± 7.3° and 113.2 ± 13.6°, respectively. The average femoral rotation was 7.4 ± 3.4°, and the average medial and lateral rollback were 2.4 ± 4.8 mm and 7.2 ± 5.6 mm, respectively. The multiple regression analysis revealed that the maximum flexion angle significantly contributed to symptoms and satisfaction. In addition, lateral rollback was also a significant factor affecting patient satisfaction. Lateral rollback and lateral Anterior-Posterior (AP) position at maximum flexion were correlated with the maximum flexion angle, whereas femoral rotation did not correlate with flexion angles. Conclusions Maximum flexion and lateral rollback are important for better patient satisfaction after TKA. To obtain the maximum flexion angle, it was necessary to perform the normal kinematic pattern with a large amount of lateral rollback.
참고문헌 (24)
- "NIH Consensus Statement on Total Knee Replacement", NIH Consensus State Sci Statements, 20, pp.1~34 (2003)
- Bourne RB, "Patient satisfaction after total knee arthroplasty : Who is satisfied and who is not?", Clin Orthop Relat Res, 468, pp.57~63 (2010)[DOI]
- Noble PC, "The John Insall Award : patient expectations affect satisfaction with total knee arthroplasty", Clin Orthop Relat Res, 452, pp.35~43 (2006)[DOI]
- Becker R, "Expectation, satisfaction, and clinical outcome of patients after total knee arthroplasty", Knee Surg Sports Traumatol Arthrosc, 19, pp.1433~1441 (2011)[DOI]
- Scott CE, "Predicting dissatisfaction following total knee replacement. A prospective study of 1217 patients", J Bone Joint Surg Br, 92, pp.1253~1258 (2010)[DOI]
- Noble PC, "Development of a new Knee Society scoring system", Clin Orthop Relat Res, 470, pp.20~32 (2012)[DOI]
- Stiel JB, "Fluoroscopic analysis of kinematics after posterior-cruciate-retaining knee arthroplasty", J Bone Joint Surg Br, 77(B), pp.884~889 (1995)
- Banks SA, "Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy", IEEE Trans Biomed Eng, 43, pp.638~649 (1996)
- Zuffi S, "A model-based method for the reconstruction of total knee replacement kinematics", IEEE Trans Med Imaging, 18, pp.981~991 (1999)
- Yamazaki T, "Improvement of depth position in 2-D", 3-D registration of knee implants using single-plane fluoroscopy, 2004, pp.23, 602~612
- Watanabe T, "In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion", J Orthop Res, 22, pp.1044~1049 (2004)
- Tamaki M, "Factors in high-flex posterior stabilized fixed-bearing total knee arthroplasty affecting in vivo kinematics and anterior tibial post impingement during gait", J Arthroplasty, 28, pp.1722~1727 (2013)[DOI]
- Kono K, "Bicruciate-stabilized total knee arthroplasty provides good functional stability during high-flexion weight-bearing activities", Knee Surg Sports Traumatol Arthrosc, 27, pp.2096~2103 (2019)[DOI]
- Ishibashi T, "Kinematics of bicruciate and posterior stabilized total knee arthroplasty during deep knee flexion and stair climbing", J Orthop Res, 39, pp.1262~1270 (2021)[DOI]
- Konda S, "Comparison of finite helical axes of normal and anatomically designed prosthetic knees", Clin Biomech(Bristol, Avon), 65, pp.57~64 (2019)[DOI]
- Matsuda S, "Postoperative alignment and ROM affect patient satisfaction after TKA", Clin Orthop Relat Res, 471, pp.127~133 (2013)
- Furu M, "Quadriceps strength affects patient satisfaction after total knee arthroplasty", J Orthop Sci, 21, pp.38~43 (2016)[DOI]
- Nishio Y, "Intraoperative medial pivot affects deep knee flexion angle and patient-reported outcomes after total knee arthroplasty", J Arthroplasty, 29, pp.702~706 (2014)[DOI]
- Kage T, "The association between in vivo knee kinematics and patient-reported outcomes during squatting in Bicruciate-stabilized total knee arthroplasty", J Knee Surg (2021)[DOI]
- Van Onsem S, "Are TKA kinematics during closed kinetic chain exercises associated with patient-reported outcomes? A preliminary analysis", Clin Orthop Relat Res, 478, pp.255~263 (2020)[DOI]
- Meccia B, "Abnormal axial rotations in TKA contribute to reduced weightbearing flexion", Clin Orthop Relat Res, 472, pp.248~253 (2014)[DOI]
- Banks SA, "In vivo kinematics of cruciate-retaining and-substituting knee arthroplasties", J Arthroplasty, 12, pp.297~304 (1997)
- Sharma A, "Femoral condylar contact points start and remain posterior in high flexing patients", J Arthroplasty, 29, pp.945~949 (2014)[DOI]
- Kono K, "The higher patient-reported outcome measure group had smaller external rotation of the femur in bicruciate-stabilized total knee arthroplasty", Knee Surg Sports Traumatol Arthrosc, 30, pp.1292~1299 (2022)[DOI]
