Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation (BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

Abstract

Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation (BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.

참고문헌 (13)

  1. 강용태, "Trnsys 를 이용한 동적 열부하 계산 및 태양열 냉방 시스템의 최적화", 석사, pp.1989
  2. 최원기, "TRNSYS를 이용한 건물 에너지 해석", pp.527~548 (2004), 도서출판 건기원
  3. Cho. S, "Predictive control of intermittently operated radiant floor heating systems", Energy Conversion and Management, 44, pp.1333~1342 (2002)
  4. Hong, T., "Building simulation : an overview of developments and information sources", Building and Environment, 35, pp.347~361 (2000)
  5. Kim, Y, "The newest air conditioning equipment", pp.462~463 (1999), Bomundang
  6. Lee, I., "Study on ventilation efficiency of a naturally ventilated broiler house - (I) Summer season", Journal of Livestock Housing and Environment, 9(1), pp.9~18 (2003)
  7. Lee, I., "Study on ventilation efficiency of a mechanically ventilated broiler house - (I) Summer season", Journal of Livestock Housing and Environment, 9(2), pp.103~112 (2003)
  8. Lee. I, , Evaluation of CFD accuracy for the ventilation study of a naturally ventilated broiler house, 41(1), pp.53~64 (2007)
  9. "SEL (Solar Energy Laboratory), 1994, TRNSYS reference manual, University of Wisconsin at Madison", ~ (1994)
  10. Seo, I., "Improvement of ventilation efficiency of a naturally ventilated broiler house in cold season", Biosystems Engineering (2007)
  11. "Statistical survey of livestock industry, 2006, National Agricultural Product Quality Management Service, Korea", ~ (2006)
  12. 유호선, "한국형 아파트의 냉난방 에너지에 미치는 제 인자의 영향", 설비공학 논문집, 14(11), pp.13~980 (2002), 대한설비공학회
  13. Xin H., "Heat and moisture production of broiler chickens in commercial housing, Livestock Environment, VI" (2002)

관련 논문AI추천

건물에너지시뮬레이션 기법을 이용한 육계사 표준설계모델의 에너지 부하 산출권경석, 김종복, 양가영, 장동화, 전소라, 하태환한국농공학회 · 한국농공학회논문집2023 · 제65권 제1호BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의권경석, 김락우, 양가영, 여욱현, 우샘이, 이동현, 이상연, 이인복, 이준엽, 최희철, 하태환, 홍세운한국농공학회 · 한국농공학회논문집2018 · 제60권 제2호강제환기식 돈사의 환기 효율성 분석을 위한 CFD 모델 개발권경석, 김현태, 서일환, 유재인, 이인복, 하태환, 홍세운, 황현섭, Jessie P.Bitog한국농공학회 · 한국농공학회논문집2008 · 제50권 제1호전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석권경석, 김락우, 박세준, 서일환, 여욱현, 이상연, 이승노, 이인복, 조예슬, 하태환한국농공학회 · 한국농공학회논문집2015 · 제57권 제5호BES 프로그램을 이용한 국내 대표적 대형온실의 에너지 부하 예측권경석, 서일환, 이성복, 이인복, 하태환, 한창평, 홍세운, Jessie P.Bitog한국농공학회 · 한국농공학회논문집2012 · 제54권 제3호강제 환기식 육계사 내부 열환경 균일성 평가강솔뫼, 김다인, 김준규, 박세준, 이상연, 이인복, 정득영, 정효혁, 조정화한국농공학회 · 한국농공학회논문집2022 · 제64권 제6호