A Review of Current Disinfectants for Gastrointestinal Endoscopic Reprocessing
2
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Gastrointestinal endoscopy is gaining popularity for diagnostic and therapeutic purposes. However, concerns over endoscope-related nosocomial infections are increasing, together with interest by the general public in safe and efficient endoscopy. For this reason, reprocessing the gastrointestinal endoscope is an important step for effective performance of endoscopy. Disinfectants are essential to the endoscope reprocessing procedure. Before selecting an appropriate disinfectant, their characteristics, limitations and means of use must be fully understood. Herein, we review the characteristics of several currently available disinfectants, including their uses, potency, advantages, and disadvantages. Most disinfectants can be used to reprocess gastrointestinal endoscopes if the manufacturer’s guidelines are followed. The selection and use of a suitable disinfectant depends on the individual circumstances of each endoscopy suite.
Abstract
Gastrointestinal endoscopy is gaining popularity for diagnostic and therapeutic purposes. However, concerns over endoscope-related nosocomial infections are increasing, together with interest by the general public in safe and efficient endoscopy. For this reason, reprocessing the gastrointestinal endoscope is an important step for effective performance of endoscopy. Disinfectants are essential to the endoscope reprocessing procedure. Before selecting an appropriate disinfectant, their characteristics, limitations and means of use must be fully understood. Herein, we review the characteristics of several currently available disinfectants, including their uses, potency, advantages, and disadvantages. Most disinfectants can be used to reprocess gastrointestinal endoscopes if the manufacturer’s guidelines are followed. The selection and use of a suitable disinfectant depends on the individual circumstances of each endoscopy suite.
참고문헌 (29)
- Nelson DB, "Recent advances in epidemiology and prevention of gastrointestinal endoscopy related infections", Curr Opin Infect Dis, 18, pp.326~330 (2005)
- Spach DH, "Transmission of infection by gastrointestinal endoscopy and bronchoscopy", Ann Intern Med, 118, pp.117~128 (1993)
- Nelson DB, "Technology status evaluation report. Transmission of infection by gastrointestinal endoscopy. May 2001", Gastrointest Endosc, 54, pp.824~828 (2001)
- Beilenhoff U, "ESGE-ESGENA Guideline: cleaning and disinfection in gastrointestinal endoscopy", Endoscopy, 40, pp.939~957 (2008)
- Favero MS, "Disinfection of medical and surgeical materials, In Disinfection, Sterilization, and Preservation. 5th ed", pp.881~917 (2001), Lippincott Williams & Wilkins
- Kim HJ, "KFDA-cleared disinfectants in gastrointestinal endoscopy", Korean J Gastrointest Endosc, 40, pp.50~52 (2010)
- "FDA-cleared sterilants and high level disinfectants with general claims for processing reusable medical and dental devices" (2009)[URL]
- The Korean Society of Gastrointestinal Endoscopy Disinfection Management Committee, "Guidebook for Cleaning and Disinfecting Gastrointestinal Endoscopes. 1st ed", pp.93~ (2012), Medbook
- Society of Gastroenterology Nurses and Associates, "SGNA guidelines for nursing care of the patient receiving sedation and analgesia in the gastrointestinal endoscopy setting", Gastroenterol Nurs, 23, pp.125~129 (2000)
- Walter V, "Reprocessing of flexible gastrointestinal endoscopes: an American Society for Gastrointestinal Endoscopy white paper", Gastroenterol Nurs, 19, pp.109~112 (1996)
- Rutala WA., "APIC guideline for selection and use of disinfectants. 1994, 1995, and 1996 APIC Guidelines Committee", Am J Infect Control, 24, pp.313~342 (1996), Association for Professionals in Infection Control and Epidemiology, Inc
- Griffiths PA, "Mycobactericidal activity of selected disinfectants using a quantitative suspension test", J Hosp Infect, 41, pp.111~121 (1999)
- Axon AT, "Disinfection in upper-digestive-tract endoscopy in Britain", Lancet, 1, pp.1093~1094 (1981)
- Cowan RE, "Aldehyde disinfectants and health in endoscopy units. British Society of Gastroenterology Endoscopy Committee", Gut, 34, pp.1641~1645 (1993)
- Hanson JM, "Glutaraldehyde as a possible cause of diarrhoea after sigmoidoscopy", Br J Surg, 85, pp.1385~1387 (1998)
- West AB, "Glutaraldehyde colitis following endoscopy: clinical and pathological features and investigation of an outbreak", Gastroenterology, 108, pp.1250~1255 (1995)
- Jonas G, "Chemical colitis due to endoscope cleaning solutions: a mimic of pseudomembranous colitis", Gastroenterology, 95, pp.1403~1408 (1988)
- Jordan SL, "The correct use of glutaraldehyde in the healthcare environment", Gastroenterol Nurs, 18, pp.143~145 (1995)
- Burkart J., "NIOSH Health Hazard Evaluation Report" (1991), U.S. Dept. of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health
- Gregory AW, "The mycobactericidal efficacy of ortho-phthalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae", Infect Control Hosp Epidemiol, 20, pp.324~330 (1999)
- Alfa MJ, "In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopes", J Hosp Infect, 26, pp.15~26 (1994)
- Rideout K, "Considering risks to healthcare workers from glutaraldehyde alternatives in highlevel disinfection", J Hosp Infect, 59, pp.4~11 (2005)
- Kim KJ., "Pros and cons of various endoscopic disinfectants", Korean J Gastrointest Endosc, 39(Suppl), pp.97S~100S (2009)
- Fraise AP, "Choosing disinfectants", J Hosp Infect, 43, pp.255~264 (1999)
- Kim H., "Characteristics and types of disinfectants", Korean J Gastrointest Endosc, 41, pp.198~201 (2010)
- Lee JH, "Efficacy of electrolyzed acid water in reprocessing patient-used flexible upper endoscopes: comparison with 2% alkaline glutaraldehyde", J Gastroenterol Hepatol, 19, pp.897~903 (2004)
- Urata M, "Comparison of the microbicidal activities of superoxidized and ozonated water in the disinfection of endoscopes", J Int Med Res, 31, pp.299~306 (2003)
- Rossi-Fedele G, "Influence of pH changes on chlorine-containing endodontic irrigating solutions", Int Endod J, 44, pp.792~799 (2011)
- BSG Endoscopy Committee Working Party, "Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee", Gut, 42, pp.585~593 (1998)