Simultaneous detection of five biocides in household products by gas chromatography-mass spectrometry
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A gas chromatography-mass spectrometric method was developed for determining 5-chloro-2-methyl- 4-isothiazolin-3-one (CMIT), 2-methyl-4-isothiazolin-3-one (MIT), 1,2-benzisothiazolin-3-one (BIT), 3-iodo-2- propynyl butyl carbamic acid (IPBC) and benzoic acid (BA) in household products. A 0.5 g sample was placed in a test tube and dissolved with 5 mL water, 5 mL methylene chloride and 1.0 mL methanol. The solution was extracted by ultra-sonication followed by mechanical shaking using the salting out effect. Under the established condition, the lowest quantification limits of all analytes were in the range of 0.04-10 mg/kg and their relative standard deviations were less than 8.0 %. The method was used to analyze 10 household products. As a result of analyzing 10 household products, MIT was detected in the range of 1.2-3.5 mg/kg in 3 of 10 samples, CMIT was detected in the range of 2.6-8.2 mg/kg in 3 of 10 samples, and BA was detected in the range of 5.0-15 mg/kg in 4 of 10 samples. Meanwhile, BIT and IPBC were not detected in any of the products. It has been shown that this method can be used for the simultaneous determination of biocides with various physical and chemical properties in household products.
Abstract
A gas chromatography-mass spectrometric method was developed for determining 5-chloro-2-methyl- 4-isothiazolin-3-one (CMIT), 2-methyl-4-isothiazolin-3-one (MIT), 1,2-benzisothiazolin-3-one (BIT), 3-iodo-2- propynyl butyl carbamic acid (IPBC) and benzoic acid (BA) in household products. A 0.5 g sample was placed in a test tube and dissolved with 5 mL water, 5 mL methylene chloride and 1.0 mL methanol. The solution was extracted by ultra-sonication followed by mechanical shaking using the salting out effect. Under the established condition, the lowest quantification limits of all analytes were in the range of 0.04-10 mg/kg and their relative standard deviations were less than 8.0 %. The method was used to analyze 10 household products. As a result of analyzing 10 household products, MIT was detected in the range of 1.2-3.5 mg/kg in 3 of 10 samples, CMIT was detected in the range of 2.6-8.2 mg/kg in 3 of 10 samples, and BA was detected in the range of 5.0-15 mg/kg in 4 of 10 samples. Meanwhile, BIT and IPBC were not detected in any of the products. It has been shown that this method can be used for the simultaneous determination of biocides with various physical and chemical properties in household products.
참고문헌 (21)
- "EUR-Lex"[URL]
- K. Taubert, , Sulfur Rep, 23(1), pp.79~121 (2002)
- L. Chen, , J. Environ. Sci, 61, pp.68~79 (2017)
- O. Aerts, , Eur. J. Dermatol, 27(2), pp.115~122 (2017)
- "US EPA"[URL]
- "WHO"[URL]
- R. Urwin, , Contact Dermatitis, 72(6), pp.381~386 (2015)
- "EUR-Lex"[URL]
- M. C. Goodier, , Dermatitis, 29(6), pp.332~338 (2018)
- H. Nakashima, , J. Health Sci, 46(6), pp.447~457 (2000)
- Jin Ju Heo, "Simultaneous quantitative analysis of four isothiazolinones and 3-iodo-2-propynyl butyl carbamate in hygienic consumer products", Environmental Engineering Research, 24(1), pp.137~143 (2019), 대한환경공학회[DOI]
- G. Alvarez-Rivera, , J. Chromatogr. A, 1270, pp.41~50 (2012)
- E. Garcia-Hidalgo, , Contact Dermatitis, 76(2), pp.96~106 (2016)
- Q. -B. Lin, , Food Addit. Contam. Part A, 27(12), pp.1775~1781 (2010)
- T. Wu, , Int. J. Cosmet. Sci, 30(5), pp.367~372 (2008)
- M. Rosero-Moreano, , J. Sep. Sci, 37(3), pp.272~280 (2014)
- I. Baranowska, , J. Chromatogr. Sci, 52(1), pp.88~94 (2014)
- N. -R. Cha, , Anal. Lett, 45(15), pp.2148~2160 (2012)
- H. Zhong, , Molecules, 24(21), pp.3894~ (2019)
- J. B. Wittenberg, , J. Sep. Sci, 38(17), pp.2983~2988 (2015)
- "Regulations on standards and methods for the analysis of household chemical products subject to safety confirmation"[URL]
