본문 바로가기
KERD
논문KCI 등재

치조골 높이가 다른 임프란트 주위 지지골 응력분석

Stress Analysis on the supporting Bone around the Implant According to the Vertical Bone Level

1

조회

0

다운로드

0

인용

0

참고문헌

주제분류치의학

초록

Abstract

-Stress Analysis on the Supporting Bone around the Implant According to the Vertical Bone Level

참고문헌 (21)

  1. "Stress distribution in bone arising from loading on endoosteal dental implants", pp.251~261 (1973)
  2. "Stress analysis of porous rooted dental implants", pp.772~777 (1976)
  3. "임플란트 매식시 수직골 높이에 따른 응력분석", 18(4), pp.302~311 (2002), 대한턱관절기능교합학회
  4. "하중의 위치 및 경사에 따른 임프란트 보철의 유한요소법적 응력분석", 19(4), pp.257~268 (2002), 대한턱관절기능교합학회
  5. "임플란트 고정체의 매식경사에 따른 응력 분석", 18(4), pp.321~329 (2002), 대한치과턱관절기능교합학회
  6. "골유착성 임프랜트 고정체의 설계변화에 따른 응력분포에 관한 삼차원 유한요소 분석적 연구", 35, pp.609~619 (1997)
  7. "Young's modulus of trabecular and cortical bone material", pp.111~119 (1993)
  8. "Micromotion and dynamic fatigue properties of the dental-implant interface", 85, pp.47~52 (2001)
  9. "Influence plants. A histometric evaluation of unloaded non-submerged implants in the canine mandible", 72, pp.1372~1383 (2001)
  10. "Stress distribution around dental implants ; Influence of superstructure length of implants and height of mandible", pp.96~102 (1992)
  11. "Finite element analysis of six endosseous implants", pp.671~676 (1990)
  12. "Application of finite element analysis in implant dentistry: a review of the literature", 85, pp.585~598 (2001)
  13. "Finite element analysis of an osseointegrated stepped screw dental implant", 30(4), pp.223~233 (2004)
  14. "Evaluation of parameters of osseointegrated dental implants using finite element analysis-a Two-dimensional comparative study examining the effects of implant diameter, implant shape, ant load directionEvaluation of parameters of osseointegrated dental implants using finite element analysis-a Two-dimensional comparative study examining the effects of implant diameter, implant shape, ant load direction", 24, pp.80~88 (1998)
  15. "The influence of bone mechanical properties and implant fixation upon bone loading around oral implants", 9, pp.407~418 (1998)
  16. "The excessive loss of Braenemark fixtures in type IV bone; a 5-year analysis", pp.2~4 (1991)
  17. "Bending overload and implant fracture: a retrospective clinical analysis", 10, pp.326~334 (1995)
  18. "Impact properties of dental materials", pp.565~570 (1970)
  19. "Throckmor foods", 76, pp.244~ (1997)
  20. "Dental implant design-effect on bone remodeling", pp.467~483 (1991)
  21. "finite-element analysis of bone around dental implants in an edentulous human mandible", pp.491~496 (1993)

관련 논문AI추천

이 간행물의 다른 논문 (9건)