Abstract

Purpose: The purpose of this study was to evaluate the influence of apical-coronal implant position on the stress distribution after occlusal and oblique loading. Materials and Methods: The cortical and cancellous bone was assumed to be isotropic, homogeneous, and linearly elastic. The implant was apposed to cortical bone in the crestal region and to cancellous bone for the remainder of the implant-bone interface. The cancellous core was surrounded by 2-mm-thick cortical bone. An axial load of 200 N was assumed and a 200-N oblique load was applied at a buccal inclination of 30 degrees to the center of the pontic and buccal cusps. The 3-D geometry modeled in Iron CAD was interfaced with ANSYS. Results: When only the stress in the bone was compared, the minimal principal stress at load Points A and B, with a axial load applied at 90 degrees or an oblique load applied at 30 degrees, for model 5. The von Mises stress in the screw of model 5 was minimal at Points A and B, for 90- and 30-degree loads. When the von Mises stress of the abutment screw was compared at Points A and B, and a 30-degree oblique load, the maximum principal stress was seen with model 2, while the minimum principal stress was with model 5. In the case of implant, the model that received maximum von Mises stress was model 1 with the load Point A and Point B, axial load applied in 90-degree, and oblique load applied in 30-degree. Discussion and Conclusions: These results suggests that implantation should be done at the supracrestal level only when necessary, since it results in higher stress than when implantation is done at or below the alveolar bone level. Within the limited this study, we recommend the use of supracrestal apical-coronal positioning in the case of clinical indications.

참고문헌 (19)

  1. "Finite element stress analysis of theinfluence of staggered versus straight placement of dentalimplants", 16, pp.722~730 (2001)
  2. "Generalizations regarding the process and phenomenon ofosseointegration. Part II. In vitrostudies", 13, pp.163~174 (1998)
  3. "Generalizations regarding the process and phenomenon ofosseointegration. Part I. In vivo studies", 13, pp.17~29 (1998)
  4. "Fixture designand overload influence marginal bone loss and fixture suc-cess in the Branemark system", 3, pp.104~111
  5. "The effect of veneering materials onstress distribution in implant-supported fixed prostheticrestorations", 15, pp.571~582 (2000)
  6. "A meta-analytic,quantitativeassessment of osseointegration establishment and evolu-tion of submerged and non-submerged endosseous titani-um oral implants", 12, pp.579~588 (2001)
  7. "Apical-coronalimplant position: recent surgical proposals. Technical note", 15, pp.865~872 (2000)
  8. "Finite element analysis of fixed prostheses at-tached to osseointegrated implants", 21, pp.563~570
  9. "A method of selecting the best implant pros-thesis design option using three-dimensional finite elementanalysis", 8, pp.662~673 (1993)
  10. "A three-di-mensional,finite-element analysis of bone around dentalimplants in an edentulous human mandible", 38, pp.491~496
  11. "Three-dimensional finite element model of a human mandible in-corporating six osseointegrated implants for stress analysisof mandibular cantilever prostheses", 10, pp.51~57 (1995)
  12. "Evaluating parameters of osseointegrated dental implantsusing finite element analysis--a two-dimensional compara-tive study examining the effects of implant diameter,im-plant shape,and load direction", 24, pp.80~88 (1998)
  13. "Application of finite elementanalysis in implant dentistry:a review of the literature", 85, pp.585~598 (2001)
  14. "Evaluation of the effect of the resid-ual bone angulation on implant-supported fixed prosthesisin mandibular posterior edentulism. Part II: 3-D finite ele-ment stress analysis", 10, pp.238~245 (2001)
  15. "Osseointegration ofrough acid-etched titanium implants:5-year follow-up of100 minimatic implants", 14, pp.384~391 (1999)
  16. "Influence of per-centage of osseointegration on stress distribution arounddental implants", 1, pp.7~11 (1998)
  17. "Implant treatment forthe posterior regions: classification" (2003), Quintessence
  18. "Occlusalforce and oral tactile sensibility measured in partially edentulouspatients with ITI implants", 10, pp.345~353 (1995)
  19. "Anisotropic elasticityof cortical and cancellous bone in the posteriormandible increases peri-implant stress and strain underoblique loading", 12, pp.648~657 (2001)

이 간행물의 다른 논문 (9건)