Coronary stent dislodgement during percutaneous coronary intervention, which occurs when the stent is passed through tortuous and calcified lesions, is not a rare complication. Without proper treatment, such as fixing with another stent in the coronary artery or removing the undeployed stent from the coronary artery or systemic artery system, this complication can cause serious problems. We experienced the unusual situation of a dismounted and dislodged coronary stent, in which retrograde retrieval to the radial artery was impossible during transradial coronary intervention. We report on use of a rendezvous and snare technique at the brachial artery level via femoral puncture, which resulted in resolution without surgery.
Abstract
Coronary stent dislodgement during percutaneous coronary intervention, which occurs when the stent is passed through tortuous and calcified lesions, is not a rare complication. Without proper treatment, such as fixing with another stent in the coronary artery or removing the undeployed stent from the coronary artery or systemic artery system, this complication can cause serious problems. We experienced the unusual situation of a dismounted and dislodged coronary stent, in which retrograde retrieval to the radial artery was impossible during transradial coronary intervention. We report on use of a rendezvous and snare technique at the brachial artery level via femoral puncture, which resulted in resolution without surgery.
참고문헌 (9)
- Shiojima I, "Thrombotic occlusion of the coronary artery associated with accidental detachment of undeployed Palmaz-Schatz stent", Cathet Cardiovasc Diagn, 38, pp.360~362 (1996)
- Kwan TW, "Approaches for dislodged stent retrieval during transradial percutaneous coronary interventions", Catheter Cardiovasc Interv, 81, pp.E245~E249 (2013)
- Rozenman Y, "Retrieval of occluding unexpanded Palmaz-Schatz stent from a saphenous aorto-coronary vein graft", Cathet Cardiovasc Diagn, 34, pp.159~161 (1995)
- Elsner M, "Intracoronary loss of balloonmounted stents: successful retrieval with a 2 mm-“Microsnare”-device", Cathet Cardiovasc Diagn, 39, pp.271~276 (1996)
- Kim MH, "Retrieval of dislodged and disfigured transradially delivered coronary stent: report on a case using forcep and antegrade brachial sheath insertion", Catheter Cardiovasc Interv, 52, pp.489~491 (2001)
- Antonellis IP, "Successful withdrawal from the right coronary artery of an NIR stent dislodged from the balloon catheter", J Interv Cardiol, 12, pp.215~217 (1999)
- 김정혁, "Successful Retrieval of Intravascular Stent Remnants With a Combination of Rotational Atherectomy and a Gooseneck Snare", Korean Circulation Journal, 42(7), pp.492~496 (2012), 대한심장학회[DOI]
- Eggebrecht H, "Nonsurgical retrieval of embolized coronary stents", Catheter Cardiovasc Interv, 51, pp.432~440 (2000)
- Kiemeneij F, "Transradial coronary angioplasty", Physicians' Multimedia Publishers, ~ (1999)