본문 바로가기
KERD
논문KCI 등재

페니실린 농도 검출을 위한 광지시형 전위차 센서의 제작 및 감응특성

Fabrication and Response Characteristics of the Light Addressable Potentiometric Sensor for Detecting the Penicillin Concentration

1

조회

0

다운로드

0

인용

0

참고문헌

주제분류공학일반

초록

Abstract

In this study, we developed the measuring system based on light addressable potentiometric sensor for the quantitative analysis of penicillin that is very important element in medicine and pharmacy, clinic. It is investigated the response characteristics by enzyme reaction with penicillinase. First, the surface pre-treatment process of the Si3N4 was established. The coupling agent was made using self assembled monolayer method and it was confirmed the immobilization process by AFM. Also, as the measuring system, potentiostat, signal processing part etc. was made by LabVIEW software, it was reduced detecting time as well as simplifying the system. Fabricated device was shown excellent pH response characteristics, 57 mV/pH in the range of pH 2~11. The response characteristics was 60 mV/decade in the range of 0.1 mM ~10 mM.

참고문헌 (19)

  1. "Field-dffect transistor sensitive to penicillin", 52, pp.1935~1937 (1980)
  2. "An ISFET-based penicillin sensor with high sensitivity, low deection limit and long life-time", 76, pp.519~526 (2001)
  3. "A novel urea sensitive biosensor witj extended dynamic range based on recombination urease and ISFETs", 19, pp.131~135 (2003)
  4. "Biosensors based on light-addressable potentiometric sensors for urea penicillin and glucose", 373, pp.9~13 (1998)
  5. "Cytosensor microphysiometer : technology and recent applications", 15, pp.149~158 (2000)
  6. "Chemical-imaging sensor using enzyme", 32, pp.23~26 (1996)
  7. "Detection of salmonella in poultry using a silicon chip-based biosensor", 41, pp.61~67 (1999)
  8. "Fabrication of potentiometric enzyme sensors based on a pH-sensitive polymer-coated Ag electrode", 35, pp.4568~4573 (1987)
  9. "Comparison of potentiometric sensors for urea and penicillin-G: differential thick-film sensors versus classical electrodes", 100, pp.131~137 (1995)
  10. "Multianalyte biosensors on optical imaging bundles", 12, pp.521~529 (1997)
  11. "H+ ISFET-based biosensor for determination of penicillin G", 13, pp.1023~1028 (1998)
  12. "Application of biosensors for diagnostic analysis and bioprocess monitoring", 65, pp.26~31 (2000)
  13. "Light addressable potentiometric sensor for biochemical systems", 240, pp.1182~ (1988)
  14. "Electrolyte", Si3N4, Si 구조의 LAPS 제작 및 pH 응답특성, 1998.
  15. "institue of Physics Publishing Bristol", pp.20~75 (1992)
  16. "Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier", 68, pp.260~265 (2000)
  17. "Chemical sensors and biosensors", John Willy & Sons, LTD
  18. "Biosensors with microvolume reaction chamber", 4, pp.1992~
  19. "Chemical imaging sensor and its application to Biological systems", 47, pp.259~263 (2001)

관련 논문AI추천

이 간행물의 다른 논문 (11건)