본문 바로가기
KERD
논문KCI 등재

ACL Reconstruction with Autologous Hamstring Tendon: Comparison of Short Term Clinical Results between Rigid-fix and PINN-ACL Cross Pin

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Purpose: To compare the short term clinical results of anterior cruciate ligament (ACL) reconstruction with autologous hamstring tendon between Rigid-fi x and PINN-ACL Cross Pin for femoral side fi xation. Materials and Methods: 127 patients who underwent arthroscopic ACL reconstruction using autologous hamstring tendon and had been followedup for over than one year were enrolled for the present study. Rigid-fi x was used in 71 cases (group 1), and PINN-ACL Cross Pin was used in 56 cases (group 2). Clinical and radiological results, operation time, and perioperative complications were compared amongst the two groups. Results: Th e International Knee Documentation Committee subjective score and Lysholm score were 94 and 95 in group 1 and 87 and 91 in group 2, with no statistical difference (p=0.892, p=0.833), respectively. However, significant difference was observed in one-leg hop test between the two groups (p=0.032). Five cases in group 1 and 40 cases in group 2 were found to be associated with perioperative complications with statistical diff erence (p<0.0001). Conclusions: Th ere was no resultant diff erence between the employment of PINN-ACL Cross Pin and Rigid-fi x as femoral graft fi xation for ACL reconstruction with hamstring tendon. However, PINN-ACL Cross Pin led to complications with extensive operation times. Hence, it needs further improvement of tools for minimization of complications.

Abstract

Purpose: To compare the short term clinical results of anterior cruciate ligament (ACL) reconstruction with autologous hamstring tendon between Rigid-fi x and PINN-ACL Cross Pin for femoral side fi xation. Materials and Methods: 127 patients who underwent arthroscopic ACL reconstruction using autologous hamstring tendon and had been followedup for over than one year were enrolled for the present study. Rigid-fi x was used in 71 cases (group 1), and PINN-ACL Cross Pin was used in 56 cases (group 2). Clinical and radiological results, operation time, and perioperative complications were compared amongst the two groups. Results: Th e International Knee Documentation Committee subjective score and Lysholm score were 94 and 95 in group 1 and 87 and 91 in group 2, with no statistical difference (p=0.892, p=0.833), respectively. However, significant difference was observed in one-leg hop test between the two groups (p=0.032). Five cases in group 1 and 40 cases in group 2 were found to be associated with perioperative complications with statistical diff erence (p<0.0001). Conclusions: Th ere was no resultant diff erence between the employment of PINN-ACL Cross Pin and Rigid-fi x as femoral graft fi xation for ACL reconstruction with hamstring tendon. However, PINN-ACL Cross Pin led to complications with extensive operation times. Hence, it needs further improvement of tools for minimization of complications.

참고문헌 (15)

  1. Ahn JH, "Comparison of the clinical results of the fixation techniques to femur in ACL reconstruction using hamstring double-loops: bioscrews vs. semi-Fix", J Korean Knee Soc, 11, pp.32~38 (1999)
  2. Amis AA, "Anterior cruciate ligament replacement. Knee stability and the effects of implants", J Bone Joint Surg Br, 71, pp.819~824 (1989)
  3. Corry IS, "Arthroscopic reconstruction of the anterior cruciate ligament. A comparison of patellar tendon autograft and fourstrand hamstring tendon autograft", Am J Sports Med, 27, pp.444~454 (1999)
  4. Goldblatt JP, "Reconstruction of the anterior cruciate ligament: meta-analysis of patellar tendon versus hamstring tendon autograft", Arthroscopy, 21, pp.791~803 (2005)
  5. Aune AK, "Interference screw fi xation of hamstring vs patellar tendon graft s for anterior cruciate ligament reconstruction", Knee Surg Sports Traumatol Arthrosc, 6, pp.99~102 (1998)
  6. Brand J Jr, "Graft fi xation in cruciate ligament reconstruction", Am J Sports Med, 28, pp.761~774 (2000)
  7. Eriksson K, "A comparison of quadruple semitendinosus and patellar tendon graft s in reconstruction of the anterior cruciate ligament", J Bone Joint Surg Br, 83, pp.348~354 (2001)
  8. Milano G, "Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft : a biomechanical analysis", Arthroscopy, 22, pp.660~668 (2006)
  9. Speirs A, "Evaluation of a new femoral fixation device in a simulated anterior cruciate ligament reconstruction", Arthroscopy, 26, pp.351~357 (2010)
  10. Freedman KB, "Arthroscopic anterior cruciate ligament reconstruction: a metaanalysis comparing patellar tendon and hamstring tendon autografts", Am J Sports Med, 31, pp.2~11 (2003)
  11. Laxdal G, "A prospective randomized comparison of bonepatellar tendon-bone and hamstring grafts for anterior cruciate ligament reconstruction", Arthroscopy, 21, pp.34~42 (2005)
  12. Charlton WP, "Clinical outcome of anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft and bioabsorbable interference screw fixation", Am J Sports Med, 31, pp.518~521 (2003)
  13. Kousa P, "Th e fi xation strength of six hamstring tendon graft fi xation devices in anterior cruciate ligament reconstruction. Part I: femoral site", Am J Sports Med, 31, pp.174~181 (2003)
  14. Ahmad CS, "Mechanical properties of soft tissue femoral fi xation devices for anterior cruciate ligament reconstruction", Am J Sports Med, 32, pp.635~640 (2004)
  15. Zantop T, "Initial fi xation strength of two bioabsorbable pins for the fi xation of hamstring graft s compared to interference screw fi xation: single cycle and cyclic loading", Am J Sports Med, 32, pp.641~649 (2004)

관련 논문AI추천

Single-Bundle Anterior Cruciate Ligament Reconstruction with Semitendinosus Tendon Using the PINN-ACL CrossPin System: Minimum 4-Year Follow-up경희수, Byoung-Joo Lee, Chang-Hwa Lee, Seung-Gil Baek대한슬관절학회 · Knee Surgery and Related Research2015 · 제27권 제1호Cross Pins versus Endobutton Femoral Fixation in Hamstring Anterior Cruciate Ligament Reconstruction: Minimum 4-Year Follow-Up인용, 공재관, Chi-Young Ahn, Geon-Hyeong Kim대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제1호Comparison between Single and Dual Femoral Fixation for Anterior Cruciate Ligament Reconstruction with a Hamstring AutograftJin Goo Kim, Nam Ki Kim, Yong Seuk Lee대한슬관절학회 · Knee Surgery and Related Research2011 · 제23권 제3호One- Year Serial Follow-up Magnetic Resonance Imaging Study of RigidFix for Femoral Fixation in Anterior Cruciate Ligament Reconstruction노정호, 이재우대한슬관절학회 · Knee Surgery and Related Research2017 · 제29권 제3호A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixationAsif Naiyer, Firoz Danish, Haris K. P., Khan Mohammad Jesan, Sharma Anubhav, Waliullah Shah대한슬관절학회 · Knee Surgery and Related Research2021 · 제33권 Comparison of the Modified Transtibial Technique, Anteromedial Portal Technique and Outside-in Technique in ACL Reconstruction박강현, 손욱진, 안효세, 이동철대한슬관절학회 · Knee Surgery and Related Research2014 · 제26권 제4호

이 간행물의 다른 논문 (11건)