Comparison of diagnostic performances of slow-pull suction and standard suction in endoscopic ultrasound-guided fine needle biopsy for gastrointestinal subepithelial tumors
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background/Aims: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is integral to the diagnosis of gastrointestinal (GI) subepithelial tumors (SETs). The impact of different EUS-FNB tissue sampling techniques on specimen adequacy and diagnostic accu- racy in SETs has not been fully evaluated. This study aimed to compare the diagnostic outcomes of slow-pull (SP) and standard suction (SS) in patients with GI SETs. Methods: In this retrospective comparative study, 54 patients were enrolled. Medical records were reviewed for location and size of the target lesion, FNB needle type/size, technical order, specimen adequacy, diagnostic yield, and adverse events. The acquisition rate of adequate specimens and diagnostic accuracy were compared according to EUS-FNB techniques. Results: The mean lesion size was 42.6±36.4 mm, and most patients were diagnosed with GI stromal tumor (75.9%). The overall diag- nostic accuracies of the SP and SS techniques were 83.3% and 81.5%, respectively (p=0.800). The rates of obtaining adequate core tissue were 79.6% and 75.9%, respectively (p=0.799). No significant clinical factors affected the rate of obtaining adequate core tissue, includ- ing lesion location and size, FNB needle size, and final diagnosis. Conclusions: SP and SS had comparable diagnostic accuracies and adequate core tissue acquisition for GI SETs via EUS-FNB.
Abstract
Background/Aims: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is integral to the diagnosis of gastrointestinal (GI) subepithelial tumors (SETs). The impact of different EUS-FNB tissue sampling techniques on specimen adequacy and diagnostic accu- racy in SETs has not been fully evaluated. This study aimed to compare the diagnostic outcomes of slow-pull (SP) and standard suction (SS) in patients with GI SETs. Methods: In this retrospective comparative study, 54 patients were enrolled. Medical records were reviewed for location and size of the target lesion, FNB needle type/size, technical order, specimen adequacy, diagnostic yield, and adverse events. The acquisition rate of adequate specimens and diagnostic accuracy were compared according to EUS-FNB techniques. Results: The mean lesion size was 42.6±36.4 mm, and most patients were diagnosed with GI stromal tumor (75.9%). The overall diag- nostic accuracies of the SP and SS techniques were 83.3% and 81.5%, respectively (p=0.800). The rates of obtaining adequate core tissue were 79.6% and 75.9%, respectively (p=0.799). No significant clinical factors affected the rate of obtaining adequate core tissue, includ- ing lesion location and size, FNB needle size, and final diagnosis. Conclusions: SP and SS had comparable diagnostic accuracies and adequate core tissue acquisition for GI SETs via EUS-FNB.
참고문헌 (32)
- Dumonceau JM, "Indications, results, and clinical impact of endoscopic ultrasound(EUS)-guided sampling in gastroenterology : European Society of Gastrointestinal Endoscopy(ESGE)clinical guideline-updated January 2017", Endoscopy, 49, pp.695~714 (2017)
- Polkowski M, "Endoscopic ultrasound and endoscopic ultrasound-guided fine-needle biopsy for the diagnosis of malignant submucosal tumors", Endoscopy, 37, pp.635~645 (2005)
- Karaca C, "Accuracy of EUS in the evaluation of small gastric subepithelial lesions", Gastrointest Endosc, 71, pp.722~727 (2010)
- Rösch T, "Endoscopic ultrasonography. Accuracy of endoscopic ultrasonography in upper gastrointestinal submucosal lesions : a prospective multicenter study", Scand J Gastroenterol, 37, pp.856~862 (2002)
- Lee JH, "Clinical impact of EUS-guided Trucut biopsy results on decision making for patients with gastric subepithelial tumors ≥2 cm in diameter", Gastrointest Endosc, 74, pp.1010~1018 (2011)
- Mekky MA, "Diagnostic utility of EUS-guided FNA in patients with gastric submucosal tumors", Gastrointest Endosc, 71, pp.913~919 (2010)
- Philipper M, "Prospective comparison of endoscopic ultrasound-guided fine-needle aspiration and surgical histology in upper gastrointestinal submucosal tumors", Endoscopy, 42, pp.300~305 (2010)
- Polkowski M, "Endoscopic ultrasonography-guided biopsy for submucosal tumors : needless needling?", Endoscopy, 42, pp.324~326 (2010)
- Akahoshi K, "Preoperative diagnosis of gastrointestinal stromal tumor by endoscopic ultrasound-guided fine needle aspiration", World J Gastroenterol, 13, pp.2077~2082 (2007)
- Hoda KM, "EUS-guided sampling of suspected GI stromal tumors", Gastrointest Endosc, 69, pp.1218~1223 (2009)
- Yoshida S, "Diagnostic findings of ultrasound-guided fine-needle aspiration cytology for gastrointestinal stromal tumors : proposal of a combined cytology with newly defined features and histology diagnosis", Pathol Int, 59, pp.712~719 (2009)
- Fernandez-Esparrach G, "Endoscopic ultrasound-guided fine-needle aspiration and trucut biopsy in the diagnosis of gastric stromal tumors : a randomized crossover study", Endoscopy, 42, pp.292~299 (2010)
- Polkowski M, "Diagnostic yield and safety of endoscopic ultrasound-guided trucut biopsy in patients with gastric submucosal tumors : a prospective study", Endoscopy, 41, pp.329~334 (2009)
- de Moura DT, "EUS-guided fine-needle biopsy sampling versus FNA in the diagnosis of subepithelial lesions : a large multicenter study", Gastrointest Endosc, 92, pp.108~119 (2020)
- Facciorusso A, "Comparison between fine-needle biopsy and fine-needle aspiration for EUS-guided sampling of subepithelial lesions : a meta-analysis", Gastrointest Endosc, 91, pp.14~22 (2020)
- Affolter KE, "Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration : a systematic review and meta-analysis", Dig Dis Sci, 58, pp.1026~1034 (2013)
- Gyu Young Pih, "Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy in Gastrointestinal Subepithelial Tumors", Clinical Endoscopy, 52(4), pp.314~320 (2019), 대한소화기내시경학회[DOI]
- Tadic M, "Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods", World J Gastroenterol, 20, pp.14292~14300 (2014)
- Varadarajulu S, "Best practices in endoscopic ultrasound-guided fine-needle aspiration", Clin Gastroenterol Hepatol, 10, pp.697~703 (2012)
- Iwashita T, "High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions", Gastrointest Endosc, 77, pp.909~915 (2013)
- Matsubayashi H, "Endoscopic ultrasonography guided-fine needle aspiration for the diagnosis of solid pancreaticobiliary lesions : clinical aspects to improve the diagnosis", World J Gastroenterol, 22, pp.628~640 (2016)
- Fabbri C, "Endoscopic ultrasound-guided fine needle aspiration with 22-and 25-gauge needles in solid pancreatic masses : a prospective comparative study with randomisation of needle sequence", Dig Liver Dis, 43, pp.647~652 (2011)
- Nakai Y, "Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses", Dig Dis Sci, 59, pp.1578~1585 (2014)
- Crino SF, "Randomized trial comparing fork-tip and side-fenestrated needles for EUS-guided fine-needle biopsy of solid pancreatic lesions", Gastrointest Endosc, 92, pp.648~658 (2020)
- Crinò SF, "EUS-FNB with or without on-site evaluation for the diagnosis of solid pancreatic lesions(FROSENOR) : protocol for a multicenter randomized non-inferiority trial", Dig Liver Dis, 51, pp.901~906 (2019)
- Zhang XC, "Diagnostic efficacy of endoscopic ultrasound-guided needle sampling for upper gastrointestinal subepithelial lesions : a meta-analysis", Surg Endosc, 30, pp.2431~2441 (2016)
- Paik WH, "Prospective evaluation of new 22 gauge endoscopic ultrasound core needle using capillary sampling with stylet slow-pull technique for intra-abdominal solid masses", J Clin Gastroenterol, 49, pp.199~205 (2015)
- Antonini F, "EUS-guided tissue sampling with a 20-gauge core biopsy needle for the characterization of gastrointestinal subepithelial lesions : a multicenter study", Endosc Ultrasound, 8, pp.105~110 (2019)
- Kim DH, "Feasibility of a 20-gauge ProCore needle in EUS-guided subepithelial tumor sampling : a prospective multicenter study", BMC Gastroenterol, 18, pp.151~ (2018)
- Bang JY, "Endoscopic ultrasonography-guided biopsy using a Franseen needle design : initial assessment", Dig Endosc, 29, pp.338~346 (2017)
- Schlag C, "Endoscopic ultrasound-guided tissue sampling of small subepithelial tumors of the upper gastrointestinal tract with a 22-gauge core biopsy needle", Endosc Int Open, 5, pp.E165~E171 (2017)
- Yi M, "Prognostic value of tumor necrosis in gastrointestinal stromal tumor: a meta-analysis", Medicine(Baltimore), 98, pp.e15338~ (2019)