There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

Abstract

There are the stirring test and drain test in the daily performance test to determine the thermal performance of a domestic solar hot water system. The drain test is a test that measures the discharge heating rate while drain the hot water from the top of the storage tank and supply the city water to the bottom of the tank. From the perspective of the user, this drain test is more effective than the stirring test. In this study, the thermal performance were compared through the drain test for a passive type and an active type domestic solar hot water systems consisting of the same storage tank and collectors. At this point, a passive type was used the horizontal storage tanks, and an active type was used vertical storage tank. In the drain test, when the hot water drained up to the reference hot water temperature, an active type which have vertical storage tank represents excellent daily performance than a passive type which have horizontal storage tank regardless of weather conditions. The reason for this is because the vertical storage tank is advantageous to thermal stratification in the tank. After the drain test, the residual heat for the horizontal storage tank was much more than the vertical storage tank, but in the next day the amount of discharged heat were less than the those of vertical storage tank neither. Thus, the solar water heating system which have horizontal storage tank should be adopted preheating control method rather than separate using control method when connected with auxiliary heat source device.

참고문헌 (6)

  1. 이동원, "자연형 및 설비형 태양열 온수기의집열특성에 대한 실험적 연구", 한국태양에너지학회 논문집, 33(6), pp.12~18 (2013), 한국태양에너지학회
  2. 류남진, "태양열원 난방기의 수축열조 효율개선에 관한 연구", 한국태양에너지학회 논문집, 27(4), pp.43~50 (2007), 한국태양에너지학회
  3. Standardization of the Solar Thermal Energy System, "KIER", Ministry of Knowledge Economy, ~ (2008)
  4. 최봉수, "6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제2보 모델링 및 시뮬레이션)", 설비공학 논문집, 16(6), pp.556~565 (2004), 대한설비공학회
  5. Development of the Active Type Solar Domestic Hot Water System, "KIER", Ministry of Trade Industry Energy, ~ (2004)
  6. Lee, D.W., "Thermal Performance of the active and passive water heating systems based on annual operation", Solar Energy, 81, pp.207~215 (2007)