논문KCI 등재
Clinical Significance of Hemagglutination Grades Determined Using the IH-1000 Automated Blood Typing Instrument: Real-world Data
0
조회
0
다운로드
1
인용
0
참고문헌
주제분류병리학
참고문헌 (4)
- 신정원, "자동화 장비 IH-500과 수기법 간 ABO 혈액형 검사 비교", 대한수혈학회지, 28(2), pp.126~133 (2017), 대한수혈학회[DOI]
- 신경화, "Economic and Workflow Analysis of a Blood Bank Automated System", Annals of Laboratory Medicine, 33(4), pp.268~273 (2013), 대한진단검사의학회
- 박영춘, "ABO 및 RhD 혈액형 검사와 비예기항체 선별검사를 위한 자동화장비 IH-1000의 평가", 대한수혈학회지, 23(2), pp.127~135 (2012), 대한수혈학회
- 이자영, "국내 헌혈자의 ABO 아형 빈도와 분포", 대한수혈학회지, 21(3), pp.223~229 (2010), 대한수혈학회
관련 논문AI추천
Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies김형회, 김혜림, 신경화, 이주미, 이현지, 장철훈, 조수연대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제2호Pre-transfusion Testing Using Crossmatching Agglutination Reaction Grades Combined With Rh Subgroup Phenotyping in Patients With Autoantibodies: A Three-year Experience at a Tertiary Hospital김형회, Kim Hyerim, Kim Jongmin, Lee Hyun-Ji, Shin Kyung-Hwa대한진단검사의학회 · Annals of Laboratory Medicine2023 · 제43권 제5호Evaluation of the Automated Immunohematology Analyzer DAYMATE M김용구, 송영선, 유재은, 유해인, 이규형, 이승옥, 최현유, 제갈동욱대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제4호ABO-RhD 혈액형 검사와 비예기항체 선별검사를 위한 혈액은행 자동화장비 IH-500과 VISION Max의 평가구선회, 권계철, 김선영, 김지명, 박유미, 임영애, 임진숙대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제4호ABO Antibody Titer Testing Harmonization in Korea: A 5-Year Analysis of External Quality Control DataChung Yousun, Hwang Sang-Hyun, Kim Han Joo, Kim Hyungsuk, Ko Dae-Hyun, Oh Heung-Bum대한진단검사의학회 · Annals of Laboratory Medicine2025 · 제45권 제3호Extended Red Blood Cell Phenotype Matching Is Dependent on Ethnicity and Specificity of RBC AlloantibodiesDuck Cho, Hyun-Young Kim, Yoo Na Chung대한진단검사의학회 · Annals of Laboratory Medicine2020 · 제40권 제2호
이 간행물의 다른 논문 (14건)
Age-specific Reference Intervals for Anti-Müllerian HormonePark Haeilpp. 617-618Ex Vivo Expansion of Highly Cytotoxic Natural Killer Cells Using Optimal Culture Medium김석호pp. 619-620Age Group-specific Reference Intervals for the Elecsys Anti-Müllerian Hormone Assay in Healthy Korean Women: a Nationwide Population-based StudyJi Misuk, Kim Hyun-Ki, Min Won-Ki, Chun Sail, Lee Woochang, Yun Yeo-Min, Kim Kwang-Raepp. 621-629Practical Considerations for Clinical Laboratories in Top-down Approach for Assessing the Measurement Uncertainty of Clinical Chemistry Analytes전사일, Yun Yeo-Min, Lee Woochang, Min Won-Ki, Hong Jinyoung, Lee Woo-In, Gu Hyunjung, Lee Juheepp. 630-637Natural Killer Cell Expansion and Cytotoxicity Differ Depending on the Culture Medium Used신수, Lim Yuree, Phan Minh-Trang Thi, Kim Jinho, Hwang Ilwoong, Ahn Yong-Oon, Doh Junsang, Park Jeehun, Koh Seung Kwon, Cho Duck, 김성은pp. 638-649