가습기살균제 환경노출 판정등급에 따른 개인 노출 특성 분포 - 4-1차와 4-2차 신청자를 중심으로
Individual Exposure Characteristics to Humidifier Disinfectant according to Exposure Classification Groups - Focusing on 4-1 and 4-2 Applicants
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Objective: This study was performed to investigate the distribution of individual exposure characteristics according to an exposure assessment classification for humidifier disinfectant and to identify the factors that influence assessment classification. Methods: We examined the exposure characteristics of 4,482 subjects who applied for the 4-1 and 4-2 assessments of environmental exposure to humidifier disinfectant conducted by the Korea Environmental Industry & Technology Institute (KEITI). Environmental exposure assessment classification was assessed using the following seven criteria: 1) Distance from humidifier to face; 2) Spray direction; 3) Time used, daytime 4) Time used, during sleep; 5) Time used, cumulative; 6) Exposure intensity; and 7) Cumulative exposure level. Each criteria was then classified as ‘high’ or low’. When participants answered for more than four criteria, exposure assessment was determined as ‘definite,’ ‘probable,’ or ‘possible’ depending on the ratio of ‘high’ responses. If participants’ responses were inconsistent, exposure assessment was listed as ‘unlikely.’ If participants answered for less than four criteria, exposure assessment was considered ‘indeterminate.’ Results: For the exposure assessment classes, definite was assigned to 38.5% (1,725 subjects), probable assigned to 32.9% (1,474 subjects), 25.0% (1,122 subjects) were assigned to as possible, unlikely assigned to 0.1% (3 subjects), and indeterminate assigned to 3.5% (158 subjects). Overall, participants who used ‘Oxy Ssakssak New Gaseupgi Dangbun,’ ‘Aekyung Gaseupgi Mate,’ ‘Homeplus Gaseupgi Chungjungje,’ and ‘E-Mart Gaseupgi Salgyunje’ totaled 2,996, 557, 176, and 162 subjects, respectively. There was a statistical difference in the type of humidifier disinfectant products between high-exposed and low-exposed participants. Based on the assessment criteria of humidifier disinfectant exposure, subjects were likely to be in the highly exposed classes (definite and probable) when the subjects were exposed 1) for more than ten hours per day and 2) for more than four hours at night 3) when the total cumulative exposure time was higher than the average, 4) when the direction of humidifier spray was toward the face, 5) when the respiratory position was less than 1 meter of distance from the humidifier, 6) when the concentration of indoor contaminants (ug/m3) was higher than the average exposure intensity, and 7) when overall exposure level (ug/m3*hr) was higher than the average exposure level. Conclusion: This study suggests that each exposure assessment criteria was able to appropriately estimate cumulative exposure levels.
Abstract
Objective: This study was performed to investigate the distribution of individual exposure characteristics according to an exposure assessment classification for humidifier disinfectant and to identify the factors that influence assessment classification. Methods: We examined the exposure characteristics of 4,482 subjects who applied for the 4-1 and 4-2 assessments of environmental exposure to humidifier disinfectant conducted by the Korea Environmental Industry & Technology Institute (KEITI). Environmental exposure assessment classification was assessed using the following seven criteria: 1) Distance from humidifier to face; 2) Spray direction; 3) Time used, daytime 4) Time used, during sleep; 5) Time used, cumulative; 6) Exposure intensity; and 7) Cumulative exposure level. Each criteria was then classified as ‘high’ or low’. When participants answered for more than four criteria, exposure assessment was determined as ‘definite,’ ‘probable,’ or ‘possible’ depending on the ratio of ‘high’ responses. If participants’ responses were inconsistent, exposure assessment was listed as ‘unlikely.’ If participants answered for less than four criteria, exposure assessment was considered ‘indeterminate.’ Results: For the exposure assessment classes, definite was assigned to 38.5% (1,725 subjects), probable assigned to 32.9% (1,474 subjects), 25.0% (1,122 subjects) were assigned to as possible, unlikely assigned to 0.1% (3 subjects), and indeterminate assigned to 3.5% (158 subjects). Overall, participants who used ‘Oxy Ssakssak New Gaseupgi Dangbun,’ ‘Aekyung Gaseupgi Mate,’ ‘Homeplus Gaseupgi Chungjungje,’ and ‘E-Mart Gaseupgi Salgyunje’ totaled 2,996, 557, 176, and 162 subjects, respectively. There was a statistical difference in the type of humidifier disinfectant products between high-exposed and low-exposed participants. Based on the assessment criteria of humidifier disinfectant exposure, subjects were likely to be in the highly exposed classes (definite and probable) when the subjects were exposed 1) for more than ten hours per day and 2) for more than four hours at night 3) when the total cumulative exposure time was higher than the average, 4) when the direction of humidifier spray was toward the face, 5) when the respiratory position was less than 1 meter of distance from the humidifier, 6) when the concentration of indoor contaminants (ug/m3) was higher than the average exposure intensity, and 7) when overall exposure level (ug/m3*hr) was higher than the average exposure level. Conclusion: This study suggests that each exposure assessment criteria was able to appropriately estimate cumulative exposure levels.
참고문헌 (9)
- 황정행, "살균제가 필요 없는 가습기 디자인 연구 - 구조와 디자인을 중심으로 한 해결 방법 -", 디지털디자인학연구, 13(4), pp.569~578 (2013), 한국디지털디자인학회[DOI]
- 하미나, "Evaluation report on the causal association between humidifier disinfectants and lung injury", Epidemiology and Health, 38, pp.1~6 (2016), 한국역학회[DOI]
- White Paper of the humidifier disinfectant health damage issue, "Committee for lung injury investigation of Center for Disease Control of Ministry of Health and Welfare", ~ (2014)
- Comprehensive portal for humidifier disinfectant damage support: Statistics, "Korea Environmental Industry & Technology Institute", ~ (2019)
- Park DU, "Estimating retrospective exposure of household humidifier disinfectants", Indoor air, 25(6), pp.631~640 (2015)
- 박동욱, "가습기 살균제 피해자 호흡기로 흡입된 가습기 살균제 양 추정 - 호흡기 외부(external) 및 내부 노출(internal exposure) 추정 방법과 사례 -", 한국환경보건학회지, 42(3), pp.141~146 (2016), 한국환경보건학회
- 최윤형, "가습기살균제 피해 신청자들의 인구학적 특성 및 노출평가 - 4-1차와 4-2차 신청자를 중심으로 -", 한국환경보건학회지, 44(4), pp.301~314 (2018), 한국환경보건학회
- 류현수, "가습기살균제 사용에 따른 피해 신청자들의 특성 및 노출평가 오류 영향요인 분석", 한국환경보건학회지, 45(1), pp.71~81 (2019), 한국환경보건학회[DOI]
- Leem JH, "Humidifier disinfectant-associated specific diseases should be called together as “humidifier disinfectant syndrome”", Environ Health Toxicol, 32, pp.e2017017~ (2017)